Accuracy of Complete-Arch Implant Photogrammetry
NCT07643441 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 42
Last updated 2026-06-11
Summary
This prospective comparative clinical study evaluated the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients rehabilitated with complete-arch implant-supported prostheses. Implant positions recorded by each system were compared with a reference dataset to assess linear and angular discrepancies. The chairside time required for data acquisition was also measured. The study aimed to determine whether mobile-phone-based photogrammetry can provide clinically acceptable accuracy comparable to that of intraoral photogrammetry while improving clinical efficiency. The findings may help clinicians select appropriate digital impression techniques for complete-arch implant rehabilitation.
Conditions
- Edentulous Jaw
Interventions
- DEVICE
-
Intraoral Photogrammetry (IPG)
A photogrammetry-based digital impression system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system records implant locations through specialized scan bodies and generates a digital dataset for subsequent accuracy analysis.
- DEVICE
-
Mobile-Phone-Based Photogrammetry
A smartphone-assisted photogrammetry system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system acquires photographic data through coded markers and generates a digital dataset for subsequent accuracy analysis.
Sponsors & Collaborators
-
Mansoura University
collaborator OTHER -
Menoufia University
lead OTHER
Principal Investigators
-
Mohammed A. El-Sawy, PhD · Menoufia University
Eligibility
- Min Age
- 18 Years
- Max Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-01-01
- Primary Completion
- 2026-08-01
- Completion
- 2026-08-01
Countries
- Egypt
Study Locations
More Related Trials
-
Truness of Full Arch Impressions in All on x Cases
NCT07550725 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
3D Integration of Facial , Intraoral Scanning and CBCT on Patient Satisfaction and Occlusion of Temporary, Permanent Implant Supported Prosthesis
NCT06846372 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparing Scanning Accuracy of Full-Arch Maxillary Implants: Extraoral vs. Intraoral Techniques
NCT06669065 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Scan Time and Prosthetic Complications of Intraoral Scanning Versus Intraoral Photogrammetry for Full-Arch Titanium Framework With Zirconia Overlay Implant Screw-Retained Prostheses
NCT07446790 ·Status: RECRUITING ·Phase: NA
-
Effect of Scanning Techniques on Accuracy of Mandibular Fixed Detachable Prostheses
NCT07740265 ·Status: RECRUITING ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06332482 ·Status: COMPLETED ·Phase: NA
-
Trueness of Full Arch Scans and Generated Digital Implant Models
NCT06281002 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06067334 ·Status: COMPLETED ·Phase: NA
-
Digitally Assisted Immediate Implants in Geriatric Patients
NCT07534514 ·Status: RECRUITING
-
Accuracy of Intraoral Photogrammetry vs Optical Scanners for Immediate Full-Arch Implant Loading
NCT07320729 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Accuracy of Computer Guided Implant Placement in Edentulous or Partially Edentulous Patients Using Artificial Intelligence Technology vs Conventional Method A Randomized Clinical Trial
NCT07627841 ·Status: COMPLETED ·Phase: NA
-
Monolithic Zirconia Full-Arch Rehabilitation Using Digital Technology
NCT07369583 ·Status: COMPLETED ·Phase: NA
-
Jaw Tracking Impact on Occlusion and Patient Outcomes in Maxillary Implant Restorations
NCT07693946 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Accuracy of Three-Dimensionally Guided Zygomatic Implant Installation
NCT07463469 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Fully Guided Versus Half Guided Implant
NCT06542562 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Digital And Direct Pickup Of Attachments With Digitally Constructed 2-Implant Overdenture Bases
NCT07238335 ·Status: COMPLETED ·Phase: NA
-
Triple-Scan Protocol to Assess Passivity
NCT07644689 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3-dimensional Printed Implant Cast Versus Conventional Stone Cast for Edentulous Mandibular Arch
NCT06050187 ·Status: UNKNOWN ·Phase: NA
-
Effect of Face Scanning on Accuracy of Dental Implant Placement in Fixed Implant Supported Maxillary Prostheses
NCT06001515 ·Status: RECRUITING ·Phase: NA
-
Effect of Digital Versus Static Jaw Relation Record on Crestal Bone Changes Around Implants Supporting Maxillary Single Overdenture
NCT06965517 ·Status: COMPLETED ·Phase: NA
-
Digital Versus Conventional Impression Technique in Mandibular Arch
NCT05770011 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Digital Versus Conventional Full-arch Implant Impression in Maxillary Screw- Retained Implant Prosthesis
NCT05709236 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Computer Guided Four Implants Placement in Completely Edentulous Mandible
NCT06571968 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Hyaluronic Acid in Addition to Xenograft in Immediate Implant Placement Within Maxillary Esthetic Zone
NCT06783517 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Intra Oral Scanning of Edentulous Arches
NCT06146153 ·Status: COMPLETED