Comparing Scanning Accuracy of Full-Arch Maxillary Implants: Extraoral vs. Intraoral Techniques
NCT06669065 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10
Last updated 2025-05-08
Summary
Data acquisition from the patients:
After 4 months of implant placement, three impressions/scans will be made for each patient as follows:
Data 1: conventional impression using open tray transfer copings and silicon impression material. After cast verification, the scan bodies will be connected to the analogues on the master cast, which will be scanned using a laboratory scanner. The STL file will be used as a reference scan.
Data 2: The scan bodies will be connected to the implants intraorally, and an intraoral scan will be made using the intraoral scanner. The STL file will be stored for comparison.
Data 3: the scan bodies will be splinted using dental floss after being connected to the implants intraorally and then a scan will be made using the intraoral scanner. The STL file will be stored for comparison.
\- Data alignment and accuracy measurements: The accuracy measurement will be done based on ISO 5725 in which a combination of trueness and precision was approved to define the accuracy of the measurement method. (15) The scanned data will be compared as follows: the STL files from the intraoral digital scans (data 2 and 3) and the extraoral scan of the master cast (data 1) will be imported into a 3D inspection software program that is a metrology program used to analyse and compare 3D meshes. The information for both reference and targets (the scanned data to be compared) will be uploaded into the program and the area of interest of 3D meshes will be marked, The "3D Compare" function will be employed by projecting all paired points with a colour-coded map created to display the deviation patterns of the investigated surfaces. The superimpositions will be used to assess the 3D accuracy for both the digital intraoral scans with the extraoral scan of the verified stone casts.
\- Statistical analysis: Data will be collected, analysed, and then tabulated.
Conditions
- Edentulous Maxilla
Interventions
- DEVICE
-
extraoral versus intraoral scanning techniques
different data acquisition techniques for full-arch dental implants
Sponsors & Collaborators
-
Misr University for Science and Technology
lead OTHER
Principal Investigators
-
HEBA ELSARRIF · Misr University for Science and Technology
Study Design
- Allocation
- NA
- Purpose
- DEVICE_FEASIBILITY
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-06-25
- Primary Completion
- 2024-10-25
- Completion
- 2025-12-25
Countries
- Egypt
Study Locations
More Related Trials
-
Assessing the Influence of Implant Scanning Techniques on the Accuracy of Maxillary Complete-Arch Digital Scans for Implant Overdentures: A Comparative Clinical Study
NCT07295899 ·Status: NOT_YET_RECRUITING
-
Accuracy of Two Methods of Making Impressions for Complete-arch Implant Supported Fixed Prosthesis
NCT06343441 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of Fully Guided Versus Half Guided Implant
NCT06542562 ·Status: COMPLETED ·Phase: NA
-
Accuracy Evaluation of Implant Impressions: A Prospective Study
NCT06393582 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06067334 ·Status: COMPLETED ·Phase: NA
-
Trueness of Full Arch Scans and Generated Digital Implant Models
NCT06281002 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of Tooth Modified Scan Bodies as a Novel Technique
NCT06177782 ·Status: COMPLETED ·Phase: NA
-
"Patient Satisfaction with Intra-Oral Vs. Extra-Oral Scanned 3D-Printed Dentures: an in Vivo Study"
NCT06846619 ·Status: RECRUITING ·Phase: NA
-
Comparison of Conventional Impressions, Intraoral Scanners and Digital Photogrammetry for Full-arch Implant Prosthesis.
NCT06570499 ·Status: RECRUITING ·Phase: NA
-
Effect of Open Tray Versus Digital Impressions on the Passivity and Prosthetic Complications of Full Arch Screw-retained Prosthesis
NCT04848207 ·Status: UNKNOWN ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06332482 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Conventional and Digital Impression Techniques Used for Maxillary Hybrid Prosthesis
NCT05321589 ·Status: COMPLETED ·Phase: NA
-
Influence of Digitalized Impression on Single Peri-implant Soft Tissue Profile
NCT06702969 ·Status: COMPLETED ·Phase: NA
-
Fully Versus Partially Guided Implants Placement: Measurement of Accuracy of Implant Position and Passivity of Superstructures.
NCT07174791 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of Peri-Implant Tissues of Different Implant Assisted Overdentures
NCT06647199 ·Status: COMPLETED ·Phase: NA
-
Effect of Geometric Modifications of Implant Scan Bodies
NCT06040385 ·Status: COMPLETED ·Phase: NA
-
Digital Evaluation of Accuracy for Removable Partial Denture Frameworks
NCT06412159 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3-dimensional Printed Implant Cast Versus Conventional Stone Cast for Edentulous Mandibular Arch
NCT06050187 ·Status: UNKNOWN ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Two Different Healing Abutments in Single Posterior Implants
NCT06682559 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
3D Integration of Facial , Intraoral Scanning and CBCT on Patient Satisfaction and Occlusion of Temporary, Permanent Implant Supported Prosthesis
NCT06846372 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Precision of Complete-arch Digital Implant Impressions With Intraoral Scanning Versus Photogrammetry
NCT05972148 ·Status: COMPLETED ·Phase: NA
-
Denture Retention of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients
NCT07290322 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Accuracy of Guided Implant Placement Using Double Versus Triple Scan Protocol in Completely Edentulous Patients
NCT03321162 ·Status: UNKNOWN
-
Implant Placement Using Open Sinus Elevation Technique With and Without Bone Grafting Material
NCT06207604 ·Status: NOT_YET_RECRUITING ·Phase: NA