Evaluation of Accuracy of Three-Dimensionally Guided Zygomatic Implant Installation
NCT07463469 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10
Last updated 2026-03-11
Summary
This study was conducted at the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Tanta University. A prospective non-controlled clinical study was performed on ten patients with compromised zygomaticomaxillary bone. Surgical intervention was carried out using a customized surgical guide.
Pre-surgical planning was performed using computed tomography (CT) scans for each patient. Surgical guides were fabricated using direct metal laser sintering technology. Zygomatic implants were inserted using a guided surgical protocol and specialized instruments.
Postoperative CT scans were obtained to evaluate deviations between the planned and actual implant positions. Accuracy was assessed by superimposing the postoperative implant position onto the virtual pre-surgical implant plan using dedicated software. Descriptive and bivariate statistical analyses were performed.
Conditions
- Maxillary Defect Reconstruction
- Atrophic Edentulous Maxilla
Interventions
- PROCEDURE
-
zygomatic implant installation using custamized bone supported surgical guide
Zygomatic implant placement using a customized bone-supported surgical guide. Indications included: * Severe posterior maxillary bone deficiency preventing placement of conventional implants * Post-surgical maxillary defects with limited options for bone reconstruction due to inadequate soft tissue coverage * Failure of previous reconstructive procedures
Sponsors & Collaborators
-
Tanta University
lead OTHER
Principal Investigators
-
Eslam A Gharieb · Tanta University
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 25 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-06-20
- Primary Completion
- 2024-11-15
- Completion
- 2025-12-20
Countries
- Egypt
Study Locations
More Related Trials
-
The Evaluation of Facial Bone Changes After Early Implant Placement Protocols "Clinically and Radiographically".
NCT06165913 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison of Conventional Versus 3-D Printed Complete Denture Regarding Retention, Accuracy, Elctromyographic Activity and Patient Satisfaction.
NCT05834530 ·Status: COMPLETED ·Phase: NA
-
Comparative Clinical Study for Two Types of Locator Attachments for Mandibular Implant Supported Overdenture
NCT06109519 ·Status: COMPLETED ·Phase: NA
-
Different Surgical Drilling Protocols in Posterior Maxilla
NCT06334081 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Implant Placement With Simultaneous Gum Grafting
NCT01431144 ·Status: COMPLETED ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06332482 ·Status: COMPLETED ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Computer Guided Four Implants Placement in Completely Edentulous Mandible
NCT06571968 ·Status: COMPLETED ·Phase: NA
-
Immediate Dental Implant Installation With and Without Socket Shield Technique in Aesthetic Zone
NCT06881095 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
DLP Versus SLM Stackable Surgical Guide
NCT05617443 ·Status: COMPLETED ·Phase: NA
-
Effect of Implant Position on Clinical Outcomes
NCT06166316 ·Status: COMPLETED ·Phase: NA
-
Trueness of Full Arch Scans and Generated Digital Implant Models
NCT06281002 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Titanium Versus Soft Metal CAD/CAM Frameworks for All-on-4 Implant Supported Prosthesis
NCT06114966 ·Status: RECRUITING ·Phase: NA
-
Accuracy of Fully Guided Versus Half Guided Implant
NCT06542562 ·Status: COMPLETED ·Phase: NA
-
Clinical Accuracy of Patient-specific Implants in Genioplasty
NCT03456869 ·Status: UNKNOWN ·Phase: NA
-
Artificial Intelligence Assisted Socket Shield With Computer Guided Implant Placement
NCT06299449 ·Status: COMPLETED ·Phase: NA
-
Edentulous Maxilla Opposed by 2-implant Mandibular Overdenture?
NCT06050213 ·Status: UNKNOWN ·Phase: NA
-
Digital Versus Conventional Full-arch Implant Impression in Maxillary Screw- Retained Implant Prosthesis
NCT05709236 ·Status: COMPLETED ·Phase: NA
-
Three Years Radiographic Evaluation of Different Implant Retained Complete Over Denture Attachments (In Vivo Study)
NCT06962358 ·Status: COMPLETED
-
Evaluation of Implant Stability Following Maxillary Sinus Floor Elevation Through Piezoelectric Trans-crestal Approach Versus Crestal Implant Approach
NCT07433868 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Immediate Implant Placement With Immediate Professionalization in Aesthetic Area
NCT03665025 ·Status: UNKNOWN ·Phase: NA
-
Fully Guided Dental Implant Placement and Primary Stability
NCT07149987 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Computer Guided Implant Placement in Edentulous Mandible A Three-Dimensional In Vitro Study
NCT06990360 ·Status: COMPLETED
-
Accuracy of 3D Printed Maxillary Complete Dentures
NCT03613896 ·Status: UNKNOWN ·Phase: NA
-
Socket Shield Technique Versus Early Implant Placement With Contour Augmentation
NCT05261334 ·Status: UNKNOWN ·Phase: NA