Accuracy of Intraoral Photogrammetry Scanner in Complete Arch Digital Implant Impression

NCT06599294 · Status: COMPLETED · Phase: PHASE1 · Type: INTERVENTIONAL · Enrollment: 60

Last updated 2024-09-19

No results posted yet for this study

Summary

Intra oral scanning can perform a full digital workflow right on the patient's mouth. Recently an intra-oral photogrammetry scanner has been introduced in the market that can make intra-oral tissue scanning in addition to a built-in photogrammetry technology so that it can capture fixture locations through special intra-oral scan flags.

Conditions

  • Dental Implant

Interventions

PROCEDURE

Digital scanning

. For each patient three digital files will be obtained: One reference scan, one conventional IOS scan, and one IPS scan. All the STL files will be imported to dental CAD software, and scan bodies will be converted to implant multi-unit ti-base using a digital library. The updated STL files will be imported to inspection software Mimics for trueness assessments. The three-dimensional discrepancy between 2 STL files will be evaluated in terms of linear and angular deviation. A central point \& central axis of the virtual MUA ti-base was used for deviation measurements. Linear deviations will be assessed for each MUA tibase on the three-space axis (X longitudinal, Y lateral, and Z vertical) using the center of the ti-base heads for the deviation measurement. Angular deviations were assessed as the angles formed by the two lines passing perpendicularly through the centers of the test image and the reference image of each ti-base.

PROCEDURE

Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner.

. For each patient three digital files will be obtained: One reference scan, one conventional IOS scan, and one IPS scan. All the STL files will be imported to dental CAD software, and scan bodies will be converted to implant multi-unit ti-base using a digital library. The updated STL files will be imported to inspection software Mimics for trueness assessments. The three-dimensional discrepancy between 2 STL files will be evaluated in terms of linear and angular deviation. A central point \& central axis of the virtual MUA ti-base was used for deviation measurements. Linear deviations will be assessed for each MUA tibase on the three-space axis (X longitudinal, Y lateral, and Z vertical) using the center of the ti-base heads for the deviation measurement. Angular deviations were assessed as the angles formed by the two lines passing perpendicularly through the centers of the test image and the reference image of each ti-base.

Sponsors & Collaborators

  • Assiut University

    collaborator OTHER
  • Ain Shams University

    lead OTHER

Study Design

Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Model
PARALLEL

Eligibility

Min Age
20 Years
Max Age
50 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2024-06-20
Primary Completion
2024-08-10
Completion
2024-08-20

Countries

  • Egypt

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT06599294 on ClinicalTrials.gov