Effect of Face Scanning on Accuracy of Dental Implant Placement in Fixed Implant Supported Maxillary Prostheses
NCT06001515 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 12
Last updated 2023-11-13
Summary
The study will compare the accuracy of surgical guides fabricated by two different scanning protocols; facially driven scanning versus dual scanning protocol regarding the deviation of implant placement.
Conditions
- Computer-Assisted Surgery
Interventions
- DEVICE
-
Dual scan protocol
one CBCT scan for the patient while wearing the scan appliance and another scan for the appliance alone
- DEVICE
-
triple scan protocol
3D facial Scanning for the patients while wearing their dentures in addition to the dual scan protocol
Sponsors & Collaborators
-
Ain Shams University
lead OTHER
Principal Investigators
-
Noha H Nawar, BDS MSc MD · Ain Shams University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- TRIPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 50 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-11-01
- Primary Completion
- 2024-04-30
- Completion
- 2024-09-30
Countries
- Egypt
Study Locations
More Related Trials
-
Digital Versus Conventional Impression Technique in Mandibular Arch
NCT05770011 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Digital Intraoral Scanning With and Without Prefabricated Landmarks Versus Conventional Impression Technique
NCT06592066 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of Fully Guided Versus Half Guided Implant
NCT06542562 ·Status: COMPLETED ·Phase: NA
-
Fully Versus Partially Guided Implants Placement: Measurement of Accuracy of Implant Position and Passivity of Superstructures.
NCT07174791 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06332482 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3-dimensional Printed Implant Cast Versus Conventional Stone Cast for Edentulous Mandibular Arch
NCT06050187 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of Conventional and Digital Impression Techniques Used for Maxillary Hybrid Prosthesis
NCT05321589 ·Status: COMPLETED ·Phase: NA
-
Utilized Scan Body Technique For Triple Function
NCT05948254 ·Status: COMPLETED ·Phase: NA
-
Edentulous Maxilla Opposed by 2-implant Mandibular Overdenture?
NCT06050213 ·Status: UNKNOWN ·Phase: NA
-
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Guided Implant Placement Using Double Versus Triple Scan Protocol in Completely Edentulous Patients
NCT03321162 ·Status: UNKNOWN
-
Accuracy of Trephination-based Versus Drilling-based Guided Dental Implant Placement
NCT05295082 ·Status: COMPLETED ·Phase: NA
-
Two Versus Four Implant-supported Fixed Full-arch Prosthesis
NCT05290766 ·Status: COMPLETED ·Phase: NA
-
Fully Guided Dental Implant Placement and Primary Stability
NCT07149987 ·Status: COMPLETED ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06067334 ·Status: COMPLETED ·Phase: NA
-
Effect of Digital Versus Static Jaw Relation Record on Crestal Bone Changes Around Implants Supporting Maxillary Single Overdenture
NCT06965517 ·Status: COMPLETED ·Phase: NA
-
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
NCT05999760 ·Status: COMPLETED ·Phase: NA
-
Comparative Accuracy of Conventional Scan Bodies, Intra-oral Photogrammetry, and Calibrated Scan Flags in Full-Arch Implant Scanning
NCT07200440 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Three-dimensional Accuracy of Direct Digital Scanning for All on Four Implants in Comparison to a Custom-made Verification Jig in Fully Edentulous Patients
NCT07106177 ·Status: COMPLETED ·Phase: NA
-
Inferior Alveolar Nerve Lateralization With Simultaneous Implant Placement Versus the Use of Short Dental Implants
NCT03661658 ·Status: UNKNOWN ·Phase: NA
-
A Study of Surgical Guide Assisted Dental Implantation in Bangladesh
NCT05983718 ·Status: UNKNOWN ·Phase: NA
-
Comparative Clinical Study for Two Types of Locator Attachments for Mandibular Implant Supported Overdenture
NCT06109519 ·Status: COMPLETED ·Phase: NA
-
Artificial Intelligence Assisted Socket Shield With Computer Guided Implant Placement
NCT06299449 ·Status: COMPLETED ·Phase: NA
-
Accuracy Evaluation of Implant Impressions: A Prospective Study
NCT06393582 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Assessment of the Accuracy of Surgical Guide Designed From Dental Model Optical Scan Versus Impression Inversion With Markers Techniques in Computer Guided Implantology. Randomized Clinical Trial.
NCT03367949 ·Status: UNKNOWN ·Phase: NA