Comparison Between Digital And Direct Pickup Of Attachments With Digitally Constructed 2-Implant Overdenture Bases
NCT07238335 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10
Last updated 2025-11-20
Summary
Comparing digital attachment pickup prior to jaw relation registration with intraoral pickup using digitally constructed mandibular overdenture bases is the aim of this study.
Conditions
- Estimation of Bone Height Changes
Interventions
- DEVICE
-
digital pickup of attachment before jaw relation
Arm 1 - Digital Pick-up Before Jaw Relation Intervention Type: Device Description (short): Extraoral digital pick-up of ball attachments on master cast, CAD/CAM denture base fabrication, jaw relation registration, and denture insertion.
- DEVICE
-
intraoral pickup of attachment during insertion
Arm 2 - Intraoral Pick-up During Insertion Intervention Type: Device Description (short): Intraoral direct pick-up of ball attachments during denture insertion after CAD/CAM denture base fabrication and jaw relation registration.
Sponsors & Collaborators
-
Mansoura University
lead OTHER
Principal Investigators
-
mohamed m foaud, phd · faculty of dentistry Mansoura university removable Prosthodontics department
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 50 Years
- Max Age
- 60 Years
- Sex
- MALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-03-01
- Primary Completion
- 2025-10-02
- Completion
- 2026-03-31
Countries
- Egypt
Study Locations
More Related Trials
-
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812 ·Status: RECRUITING ·Phase: NA
-
Effect of Two Different Digital Construction Techniques of Implant-assisted Overdentures
NCT06720389 ·Status: COMPLETED ·Phase: NA
-
Direct Versus Indirect Pick up of the Locator Retentive Caps:(Within-patient Study)
NCT05289752 ·Status: COMPLETED ·Phase: NA
-
Comparative Clinical Study for Two Types of Locator Attachments for Mandibular Implant Supported Overdenture
NCT06109519 ·Status: COMPLETED ·Phase: NA
-
Mandibular Implant Overdenture With OT Cap Bar vs Bar Attachment
NCT07067190 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Effect of Block-out Spacer to Pick up Locator Attachments to Retain Overdenture: Peri-implant and Alveolar Bone Changes
NCT05843825 ·Status: COMPLETED ·Phase: NA
-
Effect of Digital Versus Static Jaw Relation Record on Crestal Bone Changes Around Implants Supporting Maxillary Single Overdenture
NCT06965517 ·Status: COMPLETED ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815 ·Status: COMPLETED ·Phase: NA
-
Bio-implant Root Analogue Versus Conventional Screw-type Implant for Management of Pier Abutment in Mandibular Distal Extension Cases
NCT07284680 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of the Abutment Type Following Oral Implants in Terms of the Surrounding Bone Height
NCT05350293 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Conventional and Digital Impression Techniques Used for Maxillary Hybrid Prosthesis
NCT05321589 ·Status: COMPLETED ·Phase: NA
-
Evaluation of PEEK Versus Titanium Bar Attachments With Implant Assisted Mandibular Complete Overdenture Fabricated by CAD/CAM Technology
NCT07262307 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Accuracy of 3-dimensional Printed Implant Cast Versus Conventional Stone Cast for Edentulous Mandibular Arch
NCT06050187 ·Status: UNKNOWN ·Phase: NA
-
Using Two Different Attachments in Mandibular Implant Overdenture Cases in Order to Retention and Patient Satisfaction
NCT06678945 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Effect of Implant Position on Clinical Outcomes
NCT06166316 ·Status: COMPLETED ·Phase: NA
-
Digital Intraoral Scanning With and Without Prefabricated Landmarks Versus Conventional Impression Technique
NCT06592066 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Locator Versus TITACH Attachment for Mandibular Overdentures.
NCT06228859 ·Status: RECRUITING ·Phase: NA
-
Digital Workflow Versus Functional Pick-up Techniques of Two- Implant Retained Mandibular Overdentures
NCT06995547 ·Status: COMPLETED ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06067334 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Digital Versus Conventional Techniques for Construction of Mandibular Implant Retained Overdenture
NCT06139003 ·Status: COMPLETED ·Phase: NA
-
3D Integration of Facial , Intraoral Scanning and CBCT on Patient Satisfaction and Occlusion of Temporary, Permanent Implant Supported Prosthesis
NCT06846372 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Effect of Concentrated Growth Factors on Short Implant-Supported Overdentures
NCT06880965 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Denture Retention of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients
NCT07290322 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
CD vs IOD Opposing Mandibular IOD : Bone Height Changes of the Premaxilla
NCT06752642 ·Status: COMPLETED ·Phase: NA