Jaw Tracking Impact on Occlusion and Patient Outcomes in Maxillary Implant Restorations
NCT07693946 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2026-07-09
Summary
This randomized clinical trial aims to evaluate the effect of integrating digital jaw tracking into the workflow for fabrication of full-arch maxillary implant-supported screw-retained restorations. Twenty completely edentulous maxillary patients opposing natural mandibular dentition will be randomly assigned to either a conventional workflow group or a digital jaw-tracking workflow group. The study will compare patient satisfaction and occlusal accuracy between the two groups. Patient satisfaction will be assessed using a visual analogue scale (VAS), while occlusal accuracy will be evaluated using the OccluSense system.
Conditions
- Edentulism
- Complete Maxillary Edentulism
Interventions
- PROCEDURE
-
Conventional Prosthetic Workflow
Fabrication of a full-arch maxillary implant-supported screw-retained prosthesis using conventional jaw relation records, a facebow or average-value articulator, and conventional occlusal adjustment procedures.
- PROCEDURE
-
Digital Jaw-Tracking Workflow
Fabrication of a full-arch maxillary implant-supported screw-retained prosthesis using a digital workflow with dynamic jaw tracking, virtual articulator integration, and CAD/CAM technology for patient-specific occlusal design.
Sponsors & Collaborators
-
Mansoura University
lead OTHER
Principal Investigators
-
Shahira S Mohamed, BDS · Faculty of Dentistry, Mansoura University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 50 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-12-25
- Primary Completion
- 2026-12-25
- Completion
- 2027-01-25
Countries
- Egypt
Study Locations
More Related Trials
-
Digital Workflow Versus Functional Pick-up Techniques of Two- Implant Retained Mandibular Overdentures
NCT06995547 ·Status: COMPLETED ·Phase: NA
-
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Accuracy of Three-Dimensionally Guided Zygomatic Implant Installation
NCT07463469 ·Status: COMPLETED ·Phase: NA
-
Using Two Different Attachments in Mandibular Implant Overdenture Cases in Order to Retention and Patient Satisfaction
NCT06678945 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06067334 ·Status: COMPLETED ·Phase: NA
-
Bio-implant Root Analogue Versus Conventional Screw-type Implant for Management of Pier Abutment in Mandibular Distal Extension Cases
NCT07284680 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparative Clinical Study for Two Types of Locator Attachments for Mandibular Implant Supported Overdenture
NCT06109519 ·Status: COMPLETED ·Phase: NA
-
Denture Retention of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients
NCT07290322 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Accuracy of Computer Guided Implant Placement in Edentulous or Partially Edentulous Patients Using Artificial Intelligence Technology vs Conventional Method A Randomized Clinical Trial
NCT07627841 ·Status: COMPLETED ·Phase: NA
-
"Patient Satisfaction with Intra-Oral Vs. Extra-Oral Scanned 3D-Printed Dentures: an in Vivo Study"
NCT06846619 ·Status: RECRUITING ·Phase: NA
-
Digital vs. Analog Inputs in CAD/CAM Orthodontics: A Comparative Clinical Evaluation of Palatal Expander Fabrication Workflow
NCT07338591 ·Status: NOT_YET_RECRUITING
-
Accuracy of Complete-Arch Implant Photogrammetry
NCT07643441 ·Status: RECRUITING
-
Complete Digital Workflow
NCT07091786 ·Status: ENROLLING_BY_INVITATION ·Phase: PHASE2/PHASE3
-
Fully Versus Partially Guided Implants Placement: Measurement of Accuracy of Implant Position and Passivity of Superstructures.
NCT07174791 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Effect of Implant Position on Clinical Outcomes
NCT06166316 ·Status: COMPLETED ·Phase: NA
-
Comparing Scanning Accuracy of Full-Arch Maxillary Implants: Extraoral vs. Intraoral Techniques
NCT06669065 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
NCT05999760 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Two Placement Concepts of Six Compressive
NCT07495488 ·Status: COMPLETED ·Phase: NA
-
Three-Dimensional Assessment of Maxillary Canine Retraction With and Without Power Arm
NCT06352996 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Functional Relining Versus Digital Altered Cast Using Digitally Fabricated Distal Extension Frameworks
NCT06082609 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Effect of Different Loading Protocols on Photofunctionalized Implants in the Posterior Maxilla
NCT07700914 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Accuracy of Conventional and Digital Impression Techniques Used for Maxillary Hybrid Prosthesis
NCT05321589 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Peri-Implant Tissues of Different Implant Assisted Overdentures
NCT06647199 ·Status: COMPLETED ·Phase: NA
-
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815 ·Status: COMPLETED ·Phase: NA
-
3D -Printed Single Implant Overdentures
NCT04366895 ·Status: COMPLETED ·Phase: NA