Accuracy of Guided Implant Placement Using Double Versus Triple Scan Protocol in Completely Edentulous Patients
NCT03321162 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 16
Last updated 2017-11-07
Summary
16 implant placement by surgical guide using double scan protocol versus triple scan protocol to Evaluate angular and linear deviation of virtual implants and actual implant position in completely edentulous patients according to scanning protocol C1(double scan technique) and C2 (triple scan technique) .
Conditions
- Dental Implantation
Interventions
- DIAGNOSTIC_TEST
-
scan protocol
Scanning strategy is based on multiple scans. Essentially one CT scan of the patient (usually with a scan appliance). Another CT scan of the model or scan appliance may be required (double scan technique). Such a second CT scan can be replaced by optical scanning of the model and scan appliance (triple scan technique).
Sponsors & Collaborators
-
Cairo University
lead OTHER
Eligibility
- Min Age
- 30 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-11-20
- Primary Completion
- 2018-02-28
- Completion
- 2018-02-28
More Related Trials
-
Comparing Scanning Accuracy of Full-Arch Maxillary Implants: Extraoral vs. Intraoral Techniques
NCT06669065 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Trueness of Full Arch Scans and Generated Digital Implant Models
NCT06281002 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Accuracy of Conventional Versus Digital Implant Impression Techniques
NCT04908618 ·Status: UNKNOWN ·Phase: NA
-
Inferior Alveolar Nerve Lateralization With Simultaneous Implant Placement Versus the Use of Short Dental Implants
NCT03661658 ·Status: UNKNOWN ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Influence of Abutment Angulation on Implant Failure in Immediately Placed and Restored Implants in the Esthetic Zone Using Computer Aided Surgical Guides: RCT
NCT03243695 ·Status: COMPLETED ·Phase: NA
-
Effect of Face Scanning on Accuracy of Dental Implant Placement in Fixed Implant Supported Maxillary Prostheses
NCT06001515 ·Status: RECRUITING ·Phase: NA
-
Effect of Open Tray Versus Digital Impressions on the Passivity and Prosthetic Complications of Full Arch Screw-retained Prosthesis
NCT04848207 ·Status: UNKNOWN ·Phase: NA
-
Fully Versus Partially Guided Implants Placement: Measurement of Accuracy of Implant Position and Passivity of Superstructures.
NCT07174791 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Denture Retention of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients
NCT07290322 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Three-dimensional Accuracy of Direct Digital Scanning for All on Four Implants in Comparison to a Custom-made Verification Jig in Fully Edentulous Patients
NCT07106177 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Tooth Modified Scan Bodies as a Novel Technique
NCT06177782 ·Status: COMPLETED ·Phase: NA
-
Accuracy Evaluation of Implant Impressions: A Prospective Study
NCT06393582 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Prosthetic Complications of Screw Retained Restoration
NCT03674554 ·Status: UNKNOWN ·Phase: NA
-
Assessing the Influence of Implant Scanning Techniques on the Accuracy of Maxillary Complete-Arch Digital Scans for Implant Overdentures: A Comparative Clinical Study
NCT07295899 ·Status: NOT_YET_RECRUITING
-
Clinical and Radiographic Evaluation of Implant Stability in Healed Maxillary Posterior Sites Comparing Osteotome, Osseodensification and Conventional Drilling Implant Placement Techniques
NCT06599112 ·Status: RECRUITING ·Phase: NA
-
Accuracy of Computer Guided Four Implants Placement in Completely Edentulous Mandible
NCT06571968 ·Status: COMPLETED ·Phase: NA
-
Comparing Dynamic Navigation to Static Navigation in the Implant Placement
NCT07291336 ·Status: RECRUITING ·Phase: PHASE4
-
Digital Versus Conventional Impression Technique in Mandibular Arch
NCT05770011 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Patient Satisfaction With Different Numbers of Implants
NCT05882617 ·Status: COMPLETED ·Phase: NA
-
Dental Implant Stability Placed in Healed Bony Sites Using Oversized Drilling Versus Conventional Drilling Protocol
NCT06917638 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Digital Intraoral Scanning With and Without Prefabricated Landmarks Versus Conventional Impression Technique
NCT06592066 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT
NCT04982510 ·Status: COMPLETED ·Phase: NA
-
Pink and White Esthetic Scores of Polymer-infiltrated-ceramic-network and Lithium Disilicate Implant Hybrid Abutment Crowns
NCT03220321 ·Status: UNKNOWN ·Phase: NA
-
Passive Fit of CAD/CAM Screw-retained Metal Frameworks Versus Screwmented Ones
NCT04372901 ·Status: UNKNOWN ·Phase: NA