Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT
NCT04982510 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 11
Last updated 2024-02-08
Summary
the aim of this crossover randomized controlled clinical trial is comparing retention of 3D printed maxillary complete dentures produced from thermoplastic impression trays and conventional acrylic impression trays.
The research hypothesis is that there is no difference in patient satisfaction and retention of dentures constructed from definitive impression using the conventional tray and the prefabricated thermoplastic tray
Conditions
- Edentulism Nos
Interventions
- DEVICE
-
complete denture
3D printed complete denture
Sponsors & Collaborators
-
Cairo University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- CROSSOVER
Eligibility
- Max Age
- 69 Years
- Sex
- MALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2021-08-01
- Primary Completion
- 2023-05-27
- Completion
- 2023-06-27
Countries
- Egypt
Study Locations
More Related Trials
-
Accuracy of 3D Printed Maxillary Complete Dentures
NCT03613896 ·Status: UNKNOWN ·Phase: NA
-
Conventional Versus Digital 3D Printed Complete Removable Dentures
NCT05845099 ·Status: COMPLETED ·Phase: NA
-
To Evaluate the Complete Mandibular Dentures Produced Via 3D Printing in Comparison to Those Constructed From Metal-reinforced Acrylic Resin Regarding Their Retention
NCT07061860 ·Status: COMPLETED ·Phase: NA
-
Assessment of Wear and Muscular Efficiency of 3D Printed Versus Conventional Denture Teeth: A Cross-Over In Vivo Study
NCT07035574 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Retention of Complete Denture Using Rapid Prototyping
NCT03507179 ·Status: UNKNOWN ·Phase: NA
-
Comparative Study Between Injection Molding and Additive Manufacturing Complete Denture
NCT06520280 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Three Dimensional Printed Versus Conventional Heat Cured Acrylic Complete Denture
NCT05585008 ·Status: COMPLETED ·Phase: NA
-
Effect of Open Tray Versus Digital Impressions on the Passivity and Prosthetic Complications of Full Arch Screw-retained Prosthesis
NCT04848207 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Digital 3D Printed Temporary Removable Partial Denture.
NCT06106243 ·Status: RECRUITING ·Phase: NA
-
Study of Wear in Composite Resin and Reinforced Acrylic Denture Teeth Used in Complete Denture Construction for Completely Edentulous Patients
NCT04839640 ·Status: COMPLETED ·Phase: NA
-
Complete Denture Tooth Movement in Digital Light Processing Versus Conventional Fabrication Techniques
NCT04025697 ·Status: UNKNOWN ·Phase: NA
-
3D -Printed Single Implant Overdentures
NCT04366895 ·Status: COMPLETED ·Phase: NA
-
Comparison of Patient Satisfaction and Chewing Efficiency Between Conventional and 3D Printed Complete Dentures.
NCT06103019 ·Status: COMPLETED ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction and Adaptation of Dentures Printed at 0 Versus 45 Degrees
NCT06164366 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Measuring Biting Force of Poly-amide Complete Dentures
NCT03253510 ·Status: UNKNOWN ·Phase: NA
-
Biting Force and Chewing Efficiency of Complete Dentures.
NCT04793503 ·Status: COMPLETED ·Phase: NA
-
The Accuracy of Conventional Versus Digital Implant Impression Techniques
NCT04908618 ·Status: UNKNOWN ·Phase: NA
-
Three Years Radiographic Evaluation of Different Implant Retained Complete Over Denture Attachments (In Vivo Study)
NCT06962358 ·Status: COMPLETED
-
Dimensional Accuracy of Complete Denture With Rapid Prototyping and Conventional Method
NCT03119753 ·Status: UNKNOWN ·Phase: NA
-
3D-printed Crowns Versus Prefabricated Stainless-Steel Crowns for Intermediate Restoration of Compromised First Permanent Molars
NCT06047925 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison Between Conventional and CAD/CAM Complete Dentures Designed Based on Neutral Zone Concept
NCT05990088 ·Status: COMPLETED ·Phase: NA
-
Conventional Versus Neutral-Zone CAD/CAM Dentures Restoring Mandibular Resorbed Ridges
NCT05895292 ·Status: COMPLETED ·Phase: NA
-
A Study Comparing Two Different Denture Base Materials in Implant Retained Overdentures
NCT07271641 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Chewing Efficiency of Conventional Complete Denture in Comparison to Reinforced Poly Amide Denture
NCT03391063 ·Status: UNKNOWN ·Phase: NA