Accuracy of Computer Guided Implant Placement in Edentulous Mandible A Three-Dimensional In Vitro Study
NCT06990360 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 5
Last updated 2025-05-30
Summary
Five stryofoam mandibles were included in this study to assess the accuracy of using computer guided surgical stent in placement of dental implants. The mandibles were CBCT scanned and imported to 3diagnosys software to implant planning. 8 implants were placed in each mandible virtually, 4 anterior implants and 4 posterior implants were placed. The plan was exported as STL file to be imported to the CAD software for designing of the stent. The surgical stent is printed using Micro DGP printer and invision tec e-shell 600 clear resin was used. Stainless steel sleeves were placed in the surgical guide then placed in ethanol 99% to remove the excess monomer.
The stent in placed over the mandible and sequential drilling was done until the desired osteotomies width was approached followed by the placement of the implants. Post-operative CBCT was done for the mandible including the implants to assess the accuracy, angulation and position of the placed implants
Conditions
- Edentulous Alveolar Ridge
- Edentulous Alveolar Ridge In Mandible
Interventions
- DIAGNOSTIC_TEST
-
CBCT Scanning
The Styrofoam mandibles were scanned using CBCT, which was performed for each mandible pre-operatively, the raw DICOM data set obtained from the CBCT scanning were imported to a special third-party software\* for secondary reconstruction.
Sponsors & Collaborators
-
Eslam Nashaat Saied Ahmed Mohamed
lead OTHER
Eligibility
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-05-20
- Primary Completion
- 2024-08-20
- Completion
- 2024-09-20
Countries
- Egypt
More Related Trials
-
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
NCT05999760 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3D Printed Maxillary Complete Dentures
NCT03613896 ·Status: UNKNOWN ·Phase: NA
-
Fully Versus Partially Guided Implants Placement: Measurement of Accuracy of Implant Position and Passivity of Superstructures.
NCT07174791 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815 ·Status: COMPLETED ·Phase: NA
-
Digital Intraoral Scanning With and Without Prefabricated Landmarks Versus Conventional Impression Technique
NCT06592066 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Trueness of Full Arch Scans and Generated Digital Implant Models
NCT06281002 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of the Effect of Osseodensefication Technique Versus Conventional Implant Drilling Technique in Implant Supported Mandibular Overdenture
NCT06590753 ·Status: RECRUITING ·Phase: NA
-
Comparing Dynamic Navigation to Static Navigation in the Implant Placement
NCT07291336 ·Status: RECRUITING ·Phase: PHASE4
-
Conventional Versus Neutral-Zone CAD/CAM Dentures Restoring Mandibular Resorbed Ridges
NCT05895292 ·Status: COMPLETED ·Phase: NA
-
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812 ·Status: RECRUITING ·Phase: NA
-
3D Integration of Facial , Intraoral Scanning and CBCT on Patient Satisfaction and Occlusion of Temporary, Permanent Implant Supported Prosthesis
NCT06846372 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Accuracy of Trephination-based Versus Drilling-based Guided Dental Implant Placement
NCT05295082 ·Status: COMPLETED ·Phase: NA
-
Artificial Intelligence Assisted Socket Shield With Computer Guided Implant Placement
NCT06299449 ·Status: COMPLETED ·Phase: NA
-
Computer Guided Versus Freehand Dental Implant Surgery
NCT06204692 ·Status: COMPLETED ·Phase: NA
-
3D Assessment of Mandibular Bone Loss Via STL Superimposition After Complete Denture Occlusal Adjustment
NCT06562972 ·Status: COMPLETED ·Phase: NA
-
3D -Printed Single Implant Overdentures
NCT04366895 ·Status: COMPLETED ·Phase: NA
-
Evaluation Of Innovative 3D Printed Space Maintainer Versus Conventional One
NCT04221243 ·Status: UNKNOWN ·Phase: NA
-
Comparing Scanning Accuracy of Full-Arch Maxillary Implants: Extraoral vs. Intraoral Techniques
NCT06669065 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Influence of Abutment Angulation on Implant Failure in Immediately Placed and Restored Implants in the Esthetic Zone Using Computer Aided Surgical Guides: RCT
NCT03243695 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Guided Implant Placement Using Artificial Intelligence Segmentation Versus Conventional Technique
NCT06967090 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Occlusion and Disocclusion Time in Immediately Loaded Overdentures Supported by Two Splinted Versus Non Splinted Interforaminal Implants
NCT06376019 ·Status: COMPLETED ·Phase: NA
-
"Patient Satisfaction with Intra-Oral Vs. Extra-Oral Scanned 3D-Printed Dentures: an in Vivo Study"
NCT06846619 ·Status: RECRUITING ·Phase: NA
-
Study of Wear in Composite Resin and Reinforced Acrylic Denture Teeth Used in Complete Denture Construction for Completely Edentulous Patients
NCT04839640 ·Status: COMPLETED ·Phase: NA
-
Three-dimensional Accuracy of Direct Digital Scanning for All on Four Implants in Comparison to a Custom-made Verification Jig in Fully Edentulous Patients
NCT07106177 ·Status: COMPLETED ·Phase: NA
-
Anterior Mandibular Region for Immediate Implant Placement
NCT06527950 ·Status: ACTIVE_NOT_RECRUITING