Clinical and Radiographic Evaluation of The Effect of Acetal Resin Versus PEEK on Supporting Structure of Abutment Teeth
NCT06882161 · Status: COMPLETED · Phase: PHASE3 · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2025-03-18
Summary
This study was conducted to evaluate and compare the effect of acetal resin versus Polyether ether ketone (PEEK) partial dentures on abutment teeth supporting structures in Kennedy class I mandibular partial denture cases. Clinical assessments were conducted by assessing the pocket depth (PD), plaque index (PI), and gingival index (GI). Cone beam computed tomography (CBCT) was used to assess abutment alveolar bone height change.
Conditions
- Periodontal Diseases
Interventions
- BIOLOGICAL
-
Acetal resin
Effect of acetal resin versus Polyether ether ketone (PEEK) partial dentures on abutment teeth supporting structures in Kennedy class I mandibular partial denture cases
Sponsors & Collaborators
-
Al-Azhar University
lead OTHER
Principal Investigators
-
Yasmin S Zidan, PhD · Lecturer at faculty of dental medicine for girls , Al-Azhar University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- HEALTH_SERVICES_RESEARCH
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Max Age
- 50 Years
- Sex
- MALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-05-15
- Primary Completion
- 2024-11-23
- Completion
- 2024-12-17
Countries
- Egypt
Study Locations
More Related Trials
-
Comparison Between Single Implant Retained Partial Over-denture and Conventional Partial Denture
NCT03324789 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Injection Molded Polyetheretherketone (PEEK) Framework and Cobalt Chromium Framework Removable Partial Dentures Regarding Periodontal Health of Abutment Teeth
NCT03777345 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Injection Molded PEEK Framework and Cobalt Chromium Framework in Removable Partial Denture Regarding Retention
NCT03777280 ·Status: UNKNOWN ·Phase: NA
-
A Study Comparing Two Different Denture Base Materials in Implant Retained Overdentures
NCT07271641 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Injection Molded PEEK Framework and Cobalt Chromium Framework Removable Partial Dentures Regarding Biting Force
NCT03777423 ·Status: UNKNOWN ·Phase: NA
-
Periodontal Health and Patient Satisfaction of CAD/CAM Fiber-Reinforced vs. PFM Attachments in Distal Extension RPDs
NCT06871020 ·Status: COMPLETED ·Phase: NA
-
Compare CAD/CAM Metallic RPD to Conventional Metallic RPD in Terms of Oral Health Related Quality of Life
NCT06567262 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Treatment of Peri-implant Bone Dehiscence Using Autogenous Tooth Plate
NCT06313216 ·Status: COMPLETED ·Phase: NA
-
Study of Wear in Composite Resin and Reinforced Acrylic Denture Teeth Used in Complete Denture Construction for Completely Edentulous Patients
NCT04839640 ·Status: COMPLETED ·Phase: NA
-
Digital Versus Conventional Altered Cast Techniques For Constructing Mandibular Distal Extension Removable Partial Dentures Using Digitally Fabricated Frameworks: Alveolar Bone Height Changes
NCT05899712 ·Status: COMPLETED ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of Chewing Efficiency of Conventional Complete Denture in Comparison to Reinforced Poly Amide Denture
NCT03391063 ·Status: UNKNOWN ·Phase: NA
-
Functional Relining Versus Digital Altered Cast Using Digitally Fabricated Distal Extension Frameworks
NCT06082609 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Digital Evaluation of Accuracy for Removable Partial Denture Frameworks
NCT06412159 ·Status: COMPLETED ·Phase: NA
-
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812 ·Status: RECRUITING ·Phase: NA
-
Bio-implant Root Analogue Versus Conventional Screw-type Implant for Management of Pier Abutment in Mandibular Distal Extension Cases
NCT07284680 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Patient Satisfaction, Peri-implant Parameters and Crestal Bone Evaluation of PEEK (Polyetheretherketone) Abutments Versus Zirconium Abutments Restored With PEEK Based Superstructure
NCT03714074 ·Status: UNKNOWN ·Phase: NA
-
Comparative Evaluation of Masticatory Efficiency of Implant Supported Overdenture
NCT05877092 ·Status: COMPLETED ·Phase: NA
-
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
NCT05999760 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT
NCT04982510 ·Status: COMPLETED ·Phase: NA
-
Comparison of Conventional Versus 3-D Printed Complete Denture Regarding Retention, Accuracy, Elctromyographic Activity and Patient Satisfaction.
NCT05834530 ·Status: COMPLETED ·Phase: NA
-
Single-retainer Lithium Di-silicate Versus Zirconia Resin Bonded Bridge for Replacement of an Anterior Missing Tooth.
NCT05861921 ·Status: COMPLETED ·Phase: NA
-
Comparison of Short Implant Assisted Mandibular Overdenture Designs
NCT04582162 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Effect of Osseodensefication Technique Versus Conventional Implant Drilling Technique in Implant Supported Mandibular Overdenture
NCT06590753 ·Status: RECRUITING ·Phase: NA
-
Patient Satisfaction and Dimensional Accuracy of Bre Flex and Peek for Removable Partial Dentures
NCT03025555 ·Status: UNKNOWN ·Phase: NA