Selecting the Best Ventilator Hyperinflation Settings
NCT03327610 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2017-10-31
Summary
Ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, there are no recommendations on the best ventilator settings to perform the technique. Thus, the aim of this study was to compare six modes of VHI, concerning physiological markers of efficacy and safety criteria, in order to support the optimal VHI settings selection for mechanically ventilated patients. In a randomized, controlled and crossover study, 30 mechanically ventilated patients underwent 6 modes of ventilator hyperinflation. The maximum expansion (tidal volume), expiratory flow bias criteria (inspiratory and expiratory flow patterns), overdistension (alveolar pressure), asynchronies and hemodynamic variables (mean arterial pressure and heart rate) were assessed during the interventions.
Conditions
- Respiratory Failure
- Respiration Disorders
Interventions
- OTHER
-
VC-CMV20
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV). The inspiratory flow was set at 20Lpm and the tidal volume was increased in steps of 200mL until the peak airway pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.
- OTHER
-
VC-CMV50
Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV). The inspiratory flow was set at 50Lpm and the tidal volume was increased in steps of 200mL until the peak airway pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.
- OTHER
-
PC-CMV1
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1). The inspiratory time was set at 1 second and the pressure control was increased until a peak pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.
- OTHER
-
PC-CMV3
Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1). The inspiratory time was set at 3 seconds and the pressure control was increased until a peak pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.
- OTHER
-
PSV10
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV). The cycling off was set at 10% of peak inspiratory flow and the pressure support was increased until a peak pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.
- OTHER
-
PSV25
Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV). The cycling off was set at 25% of peak inspiratory flow and the pressure support was increased until a peak pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.
Sponsors & Collaborators
-
Universidade Federal do Rio de Janeiro
collaborator OTHER -
Centro Universitário Augusto Motta
lead OTHER
Principal Investigators
-
FERNANDO S GUIMARAES, PhD · Centro Universitário Augusto Motta
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2016-07-31
- Primary Completion
- 2017-08-31
- Completion
- 2017-08-31
More Related Trials
-
VSV Versus PSV as a Weaning Mode of Mechanically Ventilated Chronic Obstructive Pulmonary Disease Patients
NCT03278795 ·Status: UNKNOWN ·Phase: NA
-
Hemodynamic Responses to Ventilator Hyperinflation Technique
NCT02739841 ·Status: COMPLETED ·Phase: NA
-
Effects of Ventilator Hyperinflation Versus Vibrocompression in Mechanically Ventilated Patients
NCT06791798 ·Status: RECRUITING ·Phase: NA
-
A Prospective Observational Cohort Study of Awake Prone Position Ventilation Strategy in Patients With Acute Respiratory Failure
NCT05570903 ·Status: UNKNOWN
-
Respiratory Mechanics and Patient-ventilator Asynchrony Index in Patients With Invasive Mechanical Ventilation
NCT02687802 ·Status: COMPLETED
-
Effects of Positional Therapy on Pulmonary Physiology in Patients Undergoing Mechanical Ventilation.
NCT04471090 ·Status: COMPLETED
-
Respiratory Mechanics and Gas Exchange Characteristics in Patient With SARS-CoV-2
NCT04486729 ·Status: UNKNOWN
-
A Validation Study of a New System for Measuring the End Expiratory Lung Volume During Mechanical Ventilation
NCT00405002 ·Status: COMPLETED
-
Association Between P0.1 and Extubation Failure in Adult Patients with Acute Hypoxemic Respiratory Failure. a Multicenter Prospective Cohort Study
NCT06662201 ·Status: ACTIVE_NOT_RECRUITING
-
Physiological Effects and Safety of Continuous High-frequency Oscillatory Ventilation in Mechanical Ventilation Patients
NCT06662630 ·Status: RECRUITING ·Phase: NA
-
Effectiveness of Low Volume and Low Pressure in Severe Hypoxemic Patients
NCT06513299 ·Status: ACTIVE_NOT_RECRUITING
-
Clinical Validation of Continuous and Non-invasive Monitoring of Effective Pulmonary Volume.
NCT04045262 ·Status: COMPLETED
-
Volume-targeted Versus Pressure-limited Noninvasive Ventilation in Patients With Acute Hypercapnic Respiratory Failure
NCT02538263 ·Status: COMPLETED ·Phase: NA
-
Oxygen Supplementation and Ventilator Hyperinflation in the Endotracheal Suction (OSVHES)
NCT02440919 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Clinical and Functional Outcomes of Critically Ill Patients With COVID-19
NCT05024500 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Ventilatory Responses to VHI in Atelectasis Patients
NCT02768350 ·Status: COMPLETED ·Phase: NA
-
Changes in Lung Aeration and Inspiratory Effort With and Without Awake Prone
NCT05719103 ·Status: RECRUITING ·Phase: NA
-
Expiratory Time Constant in Mechanically Ventilated Patients
NCT05827640 ·Status: COMPLETED
-
Efects of Noninvasive Mechanical Ventilation and Conventional Mechanical Ventilation in Patients With Severe Comunity Pneumonia
NCT00523497 ·Status: TERMINATED ·Phase: NA
-
Protective Manual Hyperinflation in Acute Mechanically Ventilated Trauma Patients
NCT01366274 ·Status: UNKNOWN ·Phase: NA
-
Different PEEP Settings of COVID-19 Induced ARDS
NCT04359251 ·Status: COMPLETED ·Phase: NA
-
Generating Evidence in ECMO Ventilation Strategies
NCT05708365 ·Status: COMPLETED ·Phase: NA
-
Inflammation and Distribution of Pulmonary Ventilation Before and After Tracheal Intubation in ARDS Patients
NCT03513809 ·Status: UNKNOWN
-
Body Lateralization and Its Effects on Respiratory Drive, Ventilation, and Pulmonary Aeration in Critically Ill Patients
NCT07323472 ·Status: RECRUITING ·Phase: NA
-
Low Versus High PEEP in Noninvasive Ventilation for Hypoxemic Respiratory Failure
NCT05193786 ·Status: COMPLETED ·Phase: NA