Effect of Dietary Sodium Intake on Vascular Endothelium

NCT01550315 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 27

Last updated 2022-01-05

Study results available
· View outcomes & findings →

Summary

The investigators will test the hypothesis that markers of vascular endothelial dysfunction will be exaggerated acutely with an extreme high sodium diet compared to an extreme low-sodium diet. The investigators will compare patients with postural orthostatic tachycardia (POTS) to healthy control subjects.

Conditions

  • Postural Tachycardia Syndrome (POTS)

Interventions

PROCEDURE

Pulsitile Arterial Tonometry (PAT) Protocol

* A blood pressure cuff will be placed on one upper arm (study arm; non-dominant), while the contralateral arm will serve as a control (control arm). * RH-PAT probes will be placed on one finger (finger II, III, or IV) of each hand (same finger on both hands). The fingers on either side of the one with the probe will be separated using soft sponge rings. * Continuous recording of pulsatile blood volume responses from both hands will be initiated. * After a 10-min equilibration period, the blood pressure cuff on the study arm will be inflated to 60 mm Hg above systolic pressure for 5 min. The cuff will then be deflated to induce reactive hyperemia, PAT recording will be stopped.

DEVICE

Calf Blood Flow in Reactive Hyperemia (CBF-RH)

Calf blood flow (CBF) will be determined using venous occlusion plethysmography and calibrated mercury strain-gauges during reactive hyperemia after a 5 min of ischemia of the distal limb. Strain-gauges will be applied to the widest part of the non-dominant calf (\~10 cm below patella). Participants will remain quietly supine for 10 min with legs elevated on foam pads above the right atrium to achieve stable baseline measurements of CBF. The venous occlusion cuff is inflated for 4 seconds at 8 seconds intervals, while monitoring the change in resistance in the system, pressure inside the measuring cuff, and 5-10 determinations are performed

DEVICE

Evaluation of Forearm-Mediated Dilation

The arm will be kept extended and immobilized at heart level. Brachial artery diameter will be measured using a high resolution ultrasonography using a linear array probe with a 5 to 17 MHz frequency range. The brachial artery will be imaged in longitudinal sections, 5-10 cm proximal to placement of an occlusion cuff in the dominant forearm just below the antecubital fossa. The probe will be held with a stereotaxic holder with micrometer movement capabilities.

Sponsors & Collaborators

  • National Institutes of Health (NIH)

    collaborator NIH
  • National Heart, Lung, and Blood Institute (NHLBI)

    collaborator NIH
  • Vanderbilt University Medical Center

    lead OTHER

Principal Investigators

  • Satish R Raj, MD MSCI · Vanderbilt University

Study Design

Allocation
NON_RANDOMIZED
Purpose
BASIC_SCIENCE
Masking
NONE
Model
CROSSOVER

Eligibility

Min Age
18 Years
Max Age
60 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2012-04-30
Primary Completion
2020-12-31
Completion
2021-09-30

Countries

  • United States

Study Locations