Trueness and Dimensional Deviation of 3D Printed Nanocomposite Maxillary Denture Base Resin (In Vivo Study)
NCT06959576 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 24
Last updated 2025-05-06
Summary
Purpose: To evaluate the effect of adding nano ZrO2 and nano TiO2 nanoparticles on trueness and dimensional deviation of maxillary 3D printed denture base resin on completely edentulous patients.
Materials and Methods: This study was carried out on 24 completely edentulous patients. The patients were divided randomly into three equal groups; Group I: Patients received 3D printed maxillary complete denture without additives, Group II: Patients received 3D printed maxillary complete denture reinforced by Nano ZrO2 (0.4%) by Wt and Group III: Patients received 3D printed maxillary complete denture reinforced by Nano TiO2 (0.4%) by Wt. Trueness was evaluated by scanning the denture using an extraoral scanner after the printing process, before insertion. Dimensional deviation was evaluated by scanning the denture using an extraoral scanner at the time of insertion and after 6 months, 12 months, and 18 months. The trueness and dimensional deviation values were analyzed using repeated measure ANOVA, followed by multiple comparison Turkey test.
Conditions
- Denture Hyperplasia
Interventions
- OTHER
-
nanoparticles
Nanoparticles improve the dimensional stability of 3D printed denture base resin, so preventing instability of the denture over time
Sponsors & Collaborators
-
Tanta University
lead OTHER
Principal Investigators
-
Houda Amin Rashad, prof · Tanta University
-
Eman Mohamed Shakal, prof · Tanta University
Study Design
- Allocation
- NA
- Purpose
- SCREENING
- Masking
- NONE
- Model
- SEQUENTIAL
Eligibility
- Min Age
- 50 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-02-15
- Primary Completion
- 2025-01-30
- Completion
- 2025-02-12
Countries
- Egypt
Study Locations
More Related Trials
-
Accuracy of 3D Printed Maxillary Complete Dentures
NCT03613896 ·Status: UNKNOWN ·Phase: NA
-
Comparative Study Between Injection Molding and Additive Manufacturing Complete Denture
NCT06520280 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812 ·Status: RECRUITING ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Measurement of the Biting Force of Rabid Heat Cured Acrylic Resin Versus Modified Conventional Acrylic
NCT03006757 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Digital 3D Printed Temporary Removable Partial Denture.
NCT06106243 ·Status: RECRUITING ·Phase: NA
-
Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT
NCT04982510 ·Status: COMPLETED ·Phase: NA
-
Comparison of Conventional Versus 3-D Printed Complete Denture Regarding Retention, Accuracy, Elctromyographic Activity and Patient Satisfaction.
NCT05834530 ·Status: COMPLETED ·Phase: NA
-
Assessment of Customized 3D Zirconium Versus Titanium Mesh for Anterior Maxillary Ridge Augmentation With Delayed Implant Placement
NCT06933030 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Conventional Versus 3D Printing Duplication Techniques of Complete Denture
NCT06588140 ·Status: COMPLETED ·Phase: NA
-
Digital Versus Conventional Full-arch Implant Impression in Maxillary Screw- Retained Implant Prosthesis
NCT05709236 ·Status: COMPLETED ·Phase: NA
-
Assessment of Wear and Muscular Efficiency of 3D Printed Versus Conventional Denture Teeth: A Cross-Over In Vivo Study
NCT07035574 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Short Implant Versus Crestal Standard Length Implant to Retain Class 1 Removable Partial Denture.
NCT06666595 ·Status: RECRUITING ·Phase: NA
-
Evaluation Of Marginal Bone Height Changes And Biting Force In Screw Retained Implant Prostheses Using Reinforced Resin Vs Monolithic Zirconium
NCT07007572 ·Status: RECRUITING ·Phase: PHASE2
-
Bioactive Microstructured Anti Microbial Precoated Surface Implant Versus Non-coated Surface Implant in Type 2 Diabetic Patients in the Mandible
NCT06528327 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Masticatory Performance and Patient Satisfaction for Conventional and 3D Printed Implant Overdentures
NCT06148727 ·Status: COMPLETED ·Phase: NA
-
To Evaluate the Complete Mandibular Dentures Produced Via 3D Printing in Comparison to Those Constructed From Metal-reinforced Acrylic Resin Regarding Their Retention
NCT07061860 ·Status: COMPLETED ·Phase: NA
-
Influence of Digitalized Impression on Single Peri-implant Soft Tissue Profile
NCT06702969 ·Status: COMPLETED ·Phase: NA
-
Conventional Versus Digital 3D Printed Complete Removable Dentures
NCT05845099 ·Status: COMPLETED ·Phase: NA
-
3D-printed Implant Overdentures
NCT04569929 ·Status: COMPLETED ·Phase: NA
-
Ultrasonic Scaler VS Erythritol for Peri-implant Maintenance of Loaded Implants With Crowns Made by Different Materials
NCT06496594 ·Status: COMPLETED ·Phase: NA
-
Biomechanical Effects of Digitally Constructed Subperiosteal Implants
NCT06362057 ·Status: RECRUITING
-
Three Dimensional Printed Versus Conventional Heat Cured Acrylic Complete Denture
NCT05585008 ·Status: COMPLETED ·Phase: NA
-
Bio-implant Root Analogue Versus Conventional Screw-type Implant for Management of Pier Abutment in Mandibular Distal Extension Cases
NCT07284680 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Abutment Macro Design and Peri-implant Tissues
NCT02546713 ·Status: COMPLETED ·Phase: NA