Statement of problem: 3D printed denture base resin is needed to reinforce Purpose: To evaluate the effects of adding nano-ZrO2 and nano-TiO2 on microbial colonization and patient satisfaction with 3D-printed maxillary complete dentures.
Materials and Methods: Twenty-four patients who needed complete dentures were randomly distributed into three equal groups. Group I: Patients used maxillary complete dentures 3D printed without additives. Group II: Patients used maxillary complete dentures 3D after reinforcement by Nano-ZrO2 (0.4%) by Wt. Group III: Patients used maxillary complete dentures 3D printed after reinforcement by Nano-TiO2 (0.4%) by Wt. For microbial evaluation, a cotton swab was taken from the mucosa and the intaglio surface of maxillary dentures, and microbial colonization was evaluated by calculating the number of colony-forming units of S. aureus on mannitol salt agar plates and C. albicans on Sabouraud's dextrose agar plates after 48 hours of incubation at insertion, 6 months, 12 months and 18 months. Patient satisfaction was evaluated 15 days after insertion and at 6, 12, and 18 months. The values of microbial colonization and patient satisfaction were analyzed via repeated-measures ANOVA followed by Tukey's multiple comparison test.
Conditions
- Denture Stomatitis
Interventions
- COMBINATION_PRODUCT
-
antimicrobial agent
Adding nanoparticles to 3Dprinted denture base resin improve the properties of the material
Sponsors & Collaborators
-
Tanta University
lead OTHER
Principal Investigators
-
Houda MA Rashad, professor · Tanta University
Study Design
- Allocation
- NA
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- SEQUENTIAL
Eligibility
- Min Age
- 50 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-02-10
- Primary Completion
- 2024-07-20
- Completion
- 2024-08-10
Countries
- Egypt
Study Locations
More Related Trials
-
Evaluation Of Marginal Bone Height Changes And Biting Force In Screw Retained Implant Prostheses Using Reinforced Resin Vs Monolithic Zirconium
NCT07007572 ·Status: RECRUITING ·Phase: PHASE2
-
Retention of Metal Reinforced Polyamide Denture Base and Heat Cured Acrylic Resin Denture Base in Complete Mandibular Denture
NCT03385746 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT
NCT04982510 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3D Printed Maxillary Complete Dentures
NCT03613896 ·Status: UNKNOWN ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Measurement of the Biting Force of Rabid Heat Cured Acrylic Resin Versus Modified Conventional Acrylic
NCT03006757 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Digital 3D Printed Temporary Removable Partial Denture.
NCT06106243 ·Status: RECRUITING ·Phase: NA
-
3D -Printed Single Implant Overdentures
NCT04366895 ·Status: COMPLETED ·Phase: NA
-
Digital Versus Conventional Full-arch Implant Impression in Maxillary Screw- Retained Implant Prosthesis
NCT05709236 ·Status: COMPLETED ·Phase: NA
-
Modified Periosteal Inhibition with Simultaneous Implant Placement in Aesthetic Zone
NCT06519773 ·Status: RECRUITING ·Phase: PHASE1/PHASE2
-
Microbial Adhesion to Metallic Versus Non Metallic Surfaces of Bounded Removable Partial Denture
NCT03008317 ·Status: UNKNOWN ·Phase: NA
-
Abutment Macro Design and Peri-implant Tissues
NCT02546713 ·Status: COMPLETED ·Phase: NA
-
Retention of Maxillary Complete Dentures Modified With Titanium Dioxide Nanoparticles: A Randomized Crossover Clinical Trial.
NCT04991064 ·Status: COMPLETED ·Phase: NA
-
Performance and Safety Use of the Nanostructured Titanium Dental Implant "KONTACT N"
NCT03582657 ·Status: COMPLETED
-
Three Years Radiographic Evaluation of Different Implant Retained Complete Over Denture Attachments (In Vivo Study)
NCT06962358 ·Status: COMPLETED
-
Dentures Biofilm and Artificial Biofilm Substitute
NCT04247438 ·Status: COMPLETED ·Phase: NA
-
Effect of Temporization on the Peri-implant Soft Tissue of Immediate Implants: Randomized Controlled Clinical Trial
NCT03970811 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Chewing Efficiency of Conventional Complete Denture in Comparison to Reinforced Poly Amide Denture
NCT03391063 ·Status: UNKNOWN ·Phase: NA
-
Conventional Versus 3D Printing Duplication Techniques of Complete Denture
NCT06588140 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction and Microbial Changes in Complete Dentures.
NCT03043456 ·Status: UNKNOWN ·Phase: NA
-
Immediate Implant With Different Filling Materials
NCT05878392 ·Status: COMPLETED ·Phase: NA
-
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812 ·Status: RECRUITING ·Phase: NA
-
Complete Denture Tooth Movement in Digital Light Processing Versus Conventional Fabrication Techniques
NCT04025697 ·Status: UNKNOWN ·Phase: NA
-
Conventional Versus Digital 3D Printed Complete Removable Dentures
NCT05845099 ·Status: COMPLETED ·Phase: NA
-
Comparative Study Between Injection Molding and Additive Manufacturing Complete Denture
NCT06520280 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA