3D-printed Implant Overdentures
NCT04569929 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 14
Last updated 2020-12-16
Summary
A randomized clinical trial (RCT) was designed. Fourteen completely edentulous participants were randomly allocated into two equal groups. All participants received two implants in the inter-foraminal area with ball attachments. Participants in the control group were rehabilitated with conventionally manufactured Polymethyl Methacrylate (PMMA) maxillary complete denture and mandibular implant overdentures while participants in intervention group received digital light processed (DLP)-printed photo-polymerizable PMMA Nextdent maxillary complete denture and mandibular implant overdentures. Follow-up appointments were scheduled at 3,6, and 12 months where data of Oral Health Impact Profile 19(OHIPEDENT19) was used to assess the OHRQoL (oral health related quality of life). In addition, denture retention was measured using digital force gauge device. Data were collected and statistically analyzed.
Conditions
- Edentulous Mouth
Interventions
- OTHER
-
(DLP)-printed photo-polymerizable PMMA Nextdent mandibular implant overdenture
The bite registration records with their corresponding master casts were digitalized using an extra oral desktop 3D scanner (3shape D850) and then stored as standard triangulation language (STL) files (Figure 1). The STL files were then imported to Dental system PREMIUM3 design software (3Shape Dental System 2018) for model analysis, surveying and blocking out, designing full permanent denture bases, and for virtual teeth set-up following the recorded inter-arch space
Sponsors & Collaborators
-
October University for Modern Sciences and Arts
lead OTHER
Principal Investigators
-
Dina Elawady, PHD · MSA
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 60 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2019-01-01
- Primary Completion
- 2020-06-05
- Completion
- 2020-08-10
Countries
- Egypt
Study Locations
More Related Trials
-
Denture Retention of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients
NCT07290322 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
3D Printing for the Fabrication of Mandibular Implant Overdentures
NCT06155630 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
To Evaluate the Complete Mandibular Dentures Produced Via 3D Printing in Comparison to Those Constructed From Metal-reinforced Acrylic Resin Regarding Their Retention
NCT07061860 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Digital 3D Printed Temporary Removable Partial Denture.
NCT06106243 ·Status: RECRUITING ·Phase: NA
-
Assessment of Wear and Muscular Efficiency of 3D Printed Versus Conventional Denture Teeth: A Cross-Over In Vivo Study
NCT07035574 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Conventional Versus 3D Printing Duplication Techniques of Complete Denture
NCT06588140 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT
NCT04982510 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Masticatory Performance and Patient Satisfaction for Conventional and 3D Printed Implant Overdentures
NCT06148727 ·Status: COMPLETED ·Phase: NA
-
Conventional Versus Digital 3D Printed Complete Removable Dentures
NCT05845099 ·Status: COMPLETED ·Phase: NA
-
Comparison of Conventional Versus 3-D Printed Complete Denture Regarding Retention, Accuracy, Elctromyographic Activity and Patient Satisfaction.
NCT05834530 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Digital Versus Conventional Techniques for Construction of Mandibular Implant Retained Overdenture
NCT06139003 ·Status: COMPLETED ·Phase: NA
-
A Study Comparing Two Different Denture Base Materials in Implant Retained Overdentures
NCT07271641 ·Status: COMPLETED ·Phase: NA
-
Digital Versus Conventional Full-arch Implant Impression in Maxillary Screw- Retained Implant Prosthesis
NCT05709236 ·Status: COMPLETED ·Phase: NA
-
The Treatment of Implant-retained Mandibular Overdentures for Edentulous Patients
NCT02846805 ·Status: UNKNOWN ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Complete Denture Tooth Movement in Digital Light Processing Versus Conventional Fabrication Techniques
NCT04025697 ·Status: UNKNOWN ·Phase: NA
-
Comparative Evaluation of Masticatory Efficiency of Implant Supported Overdenture
NCT05877092 ·Status: COMPLETED ·Phase: NA
-
3D Printed Donor Tooth Replica in Autotransplantation of Teeth
NCT04933409 ·Status: UNKNOWN ·Phase: NA
-
A Descriptive, Prospective Clinical Study to Evaluate Full Dentures Fabricated by Additive Manufacturing
NCT03997604 ·Status: WITHDRAWN
-
Clinical Results of Implant-retained Mandibular Overdentures in Edentulous Patients
NCT02850458 ·Status: UNKNOWN
-
Retention of Complete Denture Using Rapid Prototyping
NCT03507179 ·Status: UNKNOWN ·Phase: NA
-
A Smart Digital Workflow Towards High Precision and Through-Put Production for Removable Partial Dentures
NCT06273449 ·Status: RECRUITING ·Phase: NA
-
Patient Satisfaction & Retention of Milled, 3D Printed and Conventional Complete Dentures
NCT03281603 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Abutment Type Following Oral Implants in Terms of the Surrounding Bone Height
NCT05350293 ·Status: COMPLETED ·Phase: NA
-
"Patient Satisfaction with Intra-Oral Vs. Extra-Oral Scanned 3D-Printed Dentures: an in Vivo Study"
NCT06846619 ·Status: RECRUITING ·Phase: NA