Evaluation of Digital 3D Printed Temporary Removable Partial Denture.
NCT06106243 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 13
Last updated 2023-10-30
Summary
This study aims to compare oral health-related quality of life and retention between digitally- fabricated temporary flexible RDPs and conventionally-fabricated temporary flexible RDPs.
Conditions
- Partial-edentulism
- Temporary Partial Denture
- 3D Printing
- Oral Health Related Quality of Life
Interventions
- PROCEDURE
-
The conventional heat pressing temporary flexible maxillary removable partial denture
An intraoral scan will be made for each patient's maxillary and mandibular jaws in addition to digital bite registration using (Medit i700; Medit corp.) the resultant data will be exported in the form of a Standard Tessellation Language (STL) file. The denture base and the teeth will be designed using computer-aided design software (Partial Cad, Dental CAD software). Each patient will receive two RDPs, fabricated with two different manufacturing techniques. Based on randomization, the patients will start by receiving either partial denture that is fabricated by conventional heat pressing technique of 3D printed castable resin (Cast V1resin) followed by partial denture that is fabricated by 3D printing of printable resin (Flexo denture base, resin) and teeth (permanent crown,resin) or the other way around. In 3D-printed RDP, the artificial teeth will be attached to the fabricated denture bases using printable denture base resin material
- PROCEDURE
-
3D-printed and digitally designed temporary flexible maxillary removable partial denture
3D-printed and digitally designed temporary flexible maxillary removable partial denture
Sponsors & Collaborators
-
Cairo University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 30 Years
- Max Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-06-02
- Primary Completion
- 2024-08-02
- Completion
- 2024-08-30
Countries
- Egypt
Study Locations
More Related Trials
-
3D -Printed Single Implant Overdentures
NCT04366895 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT
NCT04982510 ·Status: COMPLETED ·Phase: NA
-
A Study Comparing Two Different Denture Base Materials in Implant Retained Overdentures
NCT07271641 ·Status: COMPLETED ·Phase: NA
-
Assessment of Wear and Muscular Efficiency of 3D Printed Versus Conventional Denture Teeth: A Cross-Over In Vivo Study
NCT07035574 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Surface Topography and Color Stability of Implant Supported 3D Printed Provisional Restorations
NCT06947070 ·Status: RECRUITING ·Phase: NA
-
Compare CAD/CAM Metallic RPD to Conventional Metallic RPD in Terms of Oral Health Related Quality of Life
NCT06567262 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
3D-printed Implant Overdentures
NCT04569929 ·Status: COMPLETED ·Phase: NA
-
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
NCT05999760 ·Status: COMPLETED ·Phase: NA
-
Retention of Complete Denture Using Rapid Prototyping
NCT03507179 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Patient Satisfaction Between Conventional and Digital Removable Partial Dentures
NCT07228988 ·Status: COMPLETED ·Phase: NA
-
Manually Versus Digitally Fabricated Removable Partial Dentures
NCT01191073 ·Status: COMPLETED ·Phase: NA
-
Comparison of Conventional Versus 3-D Printed Complete Denture Regarding Retention, Accuracy, Elctromyographic Activity and Patient Satisfaction.
NCT05834530 ·Status: COMPLETED ·Phase: NA
-
Digital Evaluation of Accuracy for Removable Partial Denture Frameworks
NCT06412159 ·Status: COMPLETED ·Phase: NA
-
Evaluation Of Marginal Bone Height Changes And Biting Force In Screw Retained Implant Prostheses Using Reinforced Resin Vs Monolithic Zirconium
NCT07007572 ·Status: RECRUITING ·Phase: PHASE2
-
Evaluation of Oral Health-Related Quality of Life In Patients With Conventional Complete Dentures Versus Mini-Implant Retained Overdentures: A Randomized Clinical Trial
NCT07080164 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Patient Satisfaction and Adaptation of Dentures Printed at 0 Versus 45 Degrees
NCT06164366 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Three Dimensional Printed Versus Conventional Heat Cured Acrylic Complete Denture
NCT05585008 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Masticatory Performance and Patient Satisfaction for Conventional and 3D Printed Implant Overdentures
NCT06148727 ·Status: COMPLETED ·Phase: NA
-
Implant Retained Overdenture VERSUS Implant Canine Retained Overdenture.
NCT07046104 ·Status: COMPLETED ·Phase: NA
-
Effect Of Digital Smile Design on Quality Of Life In Complete Denture Wearers
NCT06324292 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Patient Satisfaction & Retention of Milled, 3D Printed and Conventional Complete Dentures
NCT03281603 ·Status: COMPLETED ·Phase: NA
-
Complete Denture Tooth Movement in Digital Light Processing Versus Conventional Fabrication Techniques
NCT04025697 ·Status: UNKNOWN ·Phase: NA
-
3D Printing for the Fabrication of Mandibular Implant Overdentures
NCT06155630 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of Patient Satisfaction and Chewing Efficiency Between Conventional and 3D Printed Complete Dentures.
NCT06103019 ·Status: COMPLETED ·Phase: NA
-
Periodontal Health and Patient Satisfaction of CAD/CAM Fiber-Reinforced vs. PFM Attachments in Distal Extension RPDs
NCT06871020 ·Status: COMPLETED ·Phase: NA