Utilized Scan Body Technique For Triple Function
NCT05948254 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 15
Last updated 2023-07-17
Summary
A triple function scan Body were done on healed dental implant, thus simplifying the workflow for full arch cases and reducing the number of visits to only 3 visits. In this technique, scan bodies were utilized for implant position scanning, facial scan alignment and as stoppers for jaw relation capturing as scan bodies were used as stoppers for jaw relation registration.
Conditions
- Digital Technology
- Dental Implant
- Occlusion
Interventions
- PROCEDURE
-
Triple function scan body
The scan bodies were used to scan the implant position, Jaw registration and facial scan alignment, First of all scan bodies were selected according to vertical dimension of occlusion, then the emergence profile together with the selected scan body were scanned,All scan bodies were then removed from the patient mouth except one or even two that were scanned in the jaw scan step, this scan body was utilized as a stopper, the patient was asked to bite until the scan body came in contact with the lower or upper teeth in case of edentulous upper or lower arch respectively, scan body in place (in the same orientation of the previous jaw scan ) provided that at least the tip of the scan body appeared when the patient is asked to smile which would be used as a common area so that the intra oral scanner can relate the jaw scan to the lips and face.
Sponsors & Collaborators
-
Assiut University
collaborator OTHER -
Ain Shams University
lead OTHER
Principal Investigators
-
Doaa Adel-Khattab, PhD · Associate Professor Faculty of Dentistry, Ain Shams University
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 22 Years
- Max Age
- 45 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-05-11
- Primary Completion
- 2023-04-24
- Completion
- 2023-05-31
Countries
- Egypt
Study Locations
More Related Trials
-
Assessing the Influence of Implant Scanning Techniques on the Accuracy of Maxillary Complete-Arch Digital Scans for Implant Overdentures: A Comparative Clinical Study
NCT07295899 ·Status: NOT_YET_RECRUITING
-
Accuracy of Guided Implant Placement Using Double Versus Triple Scan Protocol in Completely Edentulous Patients
NCT03321162 ·Status: UNKNOWN
-
Three-dimensional Accuracy of Direct Digital Scanning for All on Four Implants in Comparison to a Custom-made Verification Jig in Fully Edentulous Patients
NCT07106177 ·Status: COMPLETED ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06067334 ·Status: COMPLETED ·Phase: NA
-
Digital Intraoral Scanning With and Without Prefabricated Landmarks Versus Conventional Impression Technique
NCT06592066 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Comparative Accuracy of Conventional Scan Bodies, Intra-oral Photogrammetry, and Calibrated Scan Flags in Full-Arch Implant Scanning
NCT07200440 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparing Scanning Accuracy of Full-Arch Maxillary Implants: Extraoral vs. Intraoral Techniques
NCT06669065 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Facial Scanning for Lip Support Assessment in Full Arch Implant Rehabilitations
NCT04753866 ·Status: COMPLETED ·Phase: NA
-
Intraoral Scanning Accuracy in the Edentulous Mandible
NCT05032170 ·Status: COMPLETED
-
Occlusion and Disocclusion Time in Immediately Loaded Overdentures Supported by Two Splinted Versus Non Splinted Interforaminal Implants
NCT06376019 ·Status: COMPLETED ·Phase: NA
-
Effect of Geometric Modifications of Implant Scan Bodies
NCT06040385 ·Status: COMPLETED ·Phase: NA
-
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration
NCT06332482 ·Status: COMPLETED ·Phase: NA
-
Effect of Digital Versus Static Jaw Relation Record on Crestal Bone Changes Around Implants Supporting Maxillary Single Overdenture
NCT06965517 ·Status: COMPLETED ·Phase: NA
-
Fully Versus Partially Guided Implants Placement: Measurement of Accuracy of Implant Position and Passivity of Superstructures.
NCT07174791 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Clinical Assessment Of Inlay Retained Bridge Designs (Tub Shaped And Inlay Shaped) In Missing Posterior Teeth Cases.
NCT03715842 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of Digital Implant Impression
NCT04627649 ·Status: UNKNOWN
-
Full-Digital Workflow in Single-Tooth Implant Rehabilitation
NCT05011604 ·Status: COMPLETED ·Phase: NA
-
Anterior Mandibular Region for Immediate Implant Placement
NCT06527950 ·Status: ACTIVE_NOT_RECRUITING
-
Accuracy of Conventional and Digital Impression Techniques Used for Maxillary Hybrid Prosthesis
NCT05321589 ·Status: COMPLETED ·Phase: NA
-
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815 ·Status: COMPLETED ·Phase: NA
-
Ultrasound Investigation of Tongue Movement for Implant Overdenture
NCT06705114 ·Status: COMPLETED ·Phase: NA
-
Biomechanical Informational Effect of Innovative Double or Triple Dental Abutment-implant: Case-series
NCT06127576 ·Status: COMPLETED
-
All on Four Versus All on Three Implant Treatment Concepts
NCT05912127 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the All-on-three Concept in Mandible.
NCT06929689 ·Status: COMPLETED ·Phase: NA