Maintenance and Tissues Conditions of Fixed Screw-Retained Implant Prosthesis Versus Implant-Retained Ball Overdentures
NCT04708132 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 54
Last updated 2021-01-13
Summary
The aim of this study was to compare the prosthetic maintenance requirements between implant-retained ball overdentures versus fixed screw- retained implant prosthesis. Clinical and radiographic changes in peri-implant tissue with using PGE2 as a PICF biomarker were also evaluated. Selected patients had been divided into two groups:
1. Group (I): twenty seven patients had received implant-Supported ball over dentures.
2. Group (II): twenty-seven patients had received screw retained restorations Interventions and study procedures
Surgical and prosthetic procedures:
Surgical Procedures A radiopaque radiographic stent was formed and was positioned in the patient's mouth during cone beam scanning. Four implants were planned with two virtual replicas, in the place of the lateral incisor and the second premolar.
The stent was fabricated. After the healing period of four months finished, the patients were recalled and the super structure was fabricated according to the type of restoration Follow-up During the 12 months follow-up period, prosthodontic complications were recorded and calculated.
Postoperative care Along with a conventional oral hygiene assessment and functional checkup, follow up visits were scheduled every 6 months and up to 12 months total follow up period.
Clinical soft tissue measurements which include plaque index (PI), gingival index (GI), and PPD were measured at the mid-facial, mid-lingual, mid-mesial, and mid-distal aspects of each fixture using a graduated plastic probe to the nearest 0.5 mm. These clinical measurements were recorded after prosthesis delivery, 6 and 12 months postoperatively. The peri-implant marginal bone loss (MBL) was assessed radiographically after prosthesis delivery, 6 and 12 months postoperatively.
• Collection of peri-implant crevicular fluid (PICF) samples: PICF was collected.
Conditions
- Prosthesis and Implant Dentistry
Interventions
- PROCEDURE
-
Screw retained restoration
Hybrid prosthesis
- PROCEDURE
-
implant-retained ball overdentures
Removable prosthesis
Sponsors & Collaborators
-
Kafrelsheikh University
lead OTHER
Principal Investigators
-
Nourhan Ragheb, PhD · Kafrelsheikh University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2019-01-01
- Primary Completion
- 2020-11-01
- Completion
- 2020-11-01
Countries
- Egypt
Study Locations
More Related Trials
-
Evaluation of Oral Health-Related Quality of Life In Patients With Conventional Complete Dentures Versus Mini-Implant Retained Overdentures: A Randomized Clinical Trial
NCT07080164 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
PEEK Retentive Elements Versus Conventional
NCT05079048 ·Status: COMPLETED ·Phase: NA
-
Denture Retention of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients
NCT07290322 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Role of a New Prosthodontics Device in Hard and Soft Tissue Changes After Subcrestal Implant Placement
NCT06182670 ·Status: COMPLETED ·Phase: NA
-
Maintenance Assessment For Implant Fixed Complete Dentures With Implant Overdentures. A RCT
NCT05815589 ·Status: COMPLETED ·Phase: NA
-
Comparative Evaluation Between One-piece and Two-piece Implants Supporting Mandibular Screw-retained All-On-Four Full-arch Prosthesis on Peri-implant Bone Changes.
NCT06790524 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Oral Health Related Quality of Life and Peri-implant Condition in Single Implant Overdenture
NCT02861313 ·Status: COMPLETED ·Phase: NA
-
Treatment of Peri-implant Bone Dehiscence Using Autogenous Tooth Plate
NCT06313216 ·Status: COMPLETED ·Phase: NA
-
Dental Implant Stability Placed in Healed Bony Sites Using Oversized Drilling Versus Conventional Drilling Protocol
NCT06917638 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Implant Retained Overdenture VERSUS Implant Canine Retained Overdenture.
NCT07046104 ·Status: COMPLETED ·Phase: NA
-
PeriImplant Soft Tissue and Marginal Bone Loss of Single Implant Mandibular Overdenture
NCT02881905 ·Status: UNKNOWN ·Phase: NA
-
Evaluation Of Marginal Bone Height Changes And Biting Force In Screw Retained Implant Prostheses Using Reinforced Resin Vs Monolithic Zirconium
NCT07007572 ·Status: RECRUITING ·Phase: PHASE2
-
Effect of PEEK and Co-Cr Framework Reinforcement on Marginal Bone Loss Around Implants Supporting a Fixed All-on-four Prosthesis in Completely Edentulous Mandibles. A Randomized Controlled Clinial Trial
NCT06591611 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
(PEEK) Housing Verses Metallic Housing of Ball and Socket Attachment on Retention of Mandibular Overdenture
NCT02950662 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Digital 3D Printed Temporary Removable Partial Denture.
NCT06106243 ·Status: RECRUITING ·Phase: NA
-
Surface Topography and Color Stability of Implant Supported 3D Printed Provisional Restorations
NCT06947070 ·Status: RECRUITING ·Phase: NA
-
Clinical Performance and Stability of Different Types of Implant Supported Overdenture
NCT05972538 ·Status: COMPLETED ·Phase: NA
-
Survival Rate of 2 Implant-supported Short-span Fixed Partial Dentures
NCT06447792 ·Status: RECRUITING
-
Direct Versus Indirect Pick up of the Locator Retentive Caps:(Within-patient Study)
NCT05289752 ·Status: COMPLETED ·Phase: NA
-
Effect of Fixed and Removable Space Maintainer on Some Salivary Parameters: An In-Vivo Study
NCT06147609 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Passive Fit of CAD/CAM Screw-retained Metal Frameworks Versus Screwmented Ones
NCT04372901 ·Status: UNKNOWN ·Phase: NA
-
Different Attachment Systems in Mandibular Single Implant Overdenture
NCT07120256 ·Status: COMPLETED ·Phase: NA
-
Influence of Implants and Locators for Improved Retention
NCT02551146 ·Status: TERMINATED ·Phase: NA
-
The Effect of Platform-Matching Versus Platform-Switching Dental Implants on Peri-implant Hard and Soft Tissue Healing
NCT02536716 ·Status: COMPLETED ·Phase: NA