Maintenance Assessment For Implant Fixed Complete Dentures With Implant Overdentures. A RCT
NCT05815589 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 44
Last updated 2023-04-18
Summary
There are two types of complications in implant prosthesis: biologic and prosthetic . Biologic complications refer to disorders in implant function that disturb the supporting peri-implant tissues resulting in mucositis or periimplantitis in severe conditions, the technical complications refer to subjecting the implant, implant parts and /or the superstructures to a damage ,such as screw loosening ,attachment wear, fracture to part of the prosthesis or some of its teeth. Prosthetic complications after the insertion of the final prosthesis may or may not lead to implant loss but lead to an increase demand for repair and maintenance.
This study aimed to assess whether the telescopic overdenture as a removable prosthesis would necessitate maintaince at frequency similar to that with screw retained hybrid overdenture as a fixed prosthesis.
Conditions
- Complications Implants
Interventions
- OTHER
-
screw retained prosthesis group
hybrid prosthesis screwed on four mandibular intra-foraminal implants
Sponsors & Collaborators
-
Cairo University
lead OTHER
Principal Investigators
-
Doaa Elkady phd · lecturer
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 50 Years
- Max Age
- 70 Years
- Sex
- MALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2019-02-12
- Primary Completion
- 2021-04-10
- Completion
- 2022-11-30
Countries
- Egypt
Study Locations
More Related Trials
-
Prosthetic Complications of Screw Retained Restoration
NCT03674554 ·Status: UNKNOWN ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Denture Retention of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients
NCT07290322 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Clinical and Radiographic Evaluation of Implants in Protective Occlusion
NCT07256379 ·Status: COMPLETED ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Single-retainer Lithium Di-silicate Versus Zirconia Resin Bonded Bridge for Replacement of an Anterior Missing Tooth.
NCT05861921 ·Status: COMPLETED ·Phase: NA
-
Passive Fit of CAD/CAM Screw-retained Metal Frameworks Versus Screwmented Ones
NCT04372901 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Locator Versus TITACH Attachment for Mandibular Overdentures.
NCT06228859 ·Status: RECRUITING ·Phase: NA
-
A Study Comparing Two Different Denture Base Materials in Implant Retained Overdentures
NCT07271641 ·Status: COMPLETED ·Phase: NA
-
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
NCT05999760 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Biological Drilling Osteotomy Protocol Versus Conventional Drilling Osteotomy Protocol
NCT06992557 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of the Dimensional Alveolar Bone Changes in Immediate Post Extraction Implant Placement
NCT06515509 ·Status: COMPLETED ·Phase: NA
-
The Evaluation of Facial Bone Changes After Early Implant Placement Protocols "Clinically and Radiographically".
NCT06165913 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Two-piece Versus Single-piece Patient-specific Titanium Subperiosteal Implants
NCT03242330 ·Status: UNKNOWN ·Phase: NA
-
Performance of CAD/CAM Milled and 3D-printed Full-arch Implant-supported Provisionals Restorations
NCT05958043 ·Status: COMPLETED ·Phase: NA
-
Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT
NCT04982510 ·Status: COMPLETED ·Phase: NA
-
Occlusion and Disocclusion Time in Immediately Loaded Overdentures Supported by Two Splinted Versus Non Splinted Interforaminal Implants
NCT06376019 ·Status: COMPLETED ·Phase: NA
-
Conventional Versus Digital 3D Printed Complete Removable Dentures
NCT05845099 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Effect of Osseodensefication Technique Versus Conventional Implant Drilling Technique in Implant Supported Mandibular Overdenture
NCT06590753 ·Status: RECRUITING ·Phase: NA
-
Comparative Evaluation Between One-piece and Two-piece Implants Supporting Mandibular Screw-retained All-On-Four Full-arch Prosthesis on Peri-implant Bone Changes.
NCT06790524 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of the Abutment Type Following Oral Implants in Terms of the Surrounding Bone Height
NCT05350293 ·Status: COMPLETED ·Phase: NA
-
Effect of Implant Position on Clinical Outcomes
NCT06166316 ·Status: COMPLETED ·Phase: NA
-
Conventional Versus Neutral-Zone CAD/CAM Dentures Restoring Mandibular Resorbed Ridges
NCT05895292 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Single Implant Retained Partial Over-denture and Conventional Partial Denture
NCT03324789 ·Status: UNKNOWN ·Phase: NA
-
Patient Satisfaction & Retention of Milled, 3D Printed and Conventional Complete Dentures
NCT03281603 ·Status: COMPLETED ·Phase: NA