Effect of Fixed and Removable Space Maintainer on Some Salivary Parameters: An In-Vivo Study
NCT06147609 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40
Last updated 2024-01-08
Summary
The aim of this study is to evaluate and compare the effect of lower lingual holding arch space maintainer versus removable partial denture space maintainer on some salivary parameters (salivary flow rate, pH, viscosity and buffering capacity).
Conditions
- Premature Loss of Primary Teeth
Interventions
- DEVICE
-
lower lingual holding arch space maintainer
lower lingual holding arch space maintainer is an orthodontic device which connects two molars lower dental arch. it has an archwire, adapted to the lingual side of the lower anterior teeth, that soldered to the bands on first permanent molar
- DEVICE
-
Removable partial denture space maintainer
Removable Partial Denture consists of a pink or gum-colored plastic base to which the new, artificial, replacement teeth are attached to. a metal framework holds the denture in place inside the mouth
Sponsors & Collaborators
-
Suez Canal University
lead OTHER
Principal Investigators
-
Yousra S Mohamed, PhD · Lecturer
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 7 Years
- Max Age
- 10 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-01-31
- Primary Completion
- 2024-12-31
- Completion
- 2024-12-31
Countries
- Egypt
Study Locations
More Related Trials
-
"Evaluation of Clinical Performance and Success Rate of CAD/CAM Versus Conventional Band and Loop Space Maintainer"
NCT05134714 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Role of a New Prosthodontics Device in Hard and Soft Tissue Changes After Subcrestal Implant Placement
NCT06182670 ·Status: COMPLETED ·Phase: NA
-
To Evaluate the Complete Mandibular Dentures Produced Via 3D Printing in Comparison to Those Constructed From Metal-reinforced Acrylic Resin Regarding Their Retention
NCT07061860 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Open-face Maxillary Complete Denture for Patients With Prominent Premaxilla
NCT06209814 ·Status: COMPLETED ·Phase: NA
-
Occlusion and Disocclusion Time in Immediately Loaded Overdentures Supported by Two Splinted Versus Non Splinted Interforaminal Implants
NCT06376019 ·Status: COMPLETED ·Phase: NA
-
Effect of Implant Position on Clinical Outcomes
NCT06166316 ·Status: COMPLETED ·Phase: NA
-
PEEK Retentive Elements Versus Conventional
NCT05079048 ·Status: COMPLETED ·Phase: NA
-
Implant Retained Overdenture VERSUS Implant Canine Retained Overdenture.
NCT07046104 ·Status: COMPLETED ·Phase: NA
-
Radiographic and Clinical Evaluation In Bar
NCT06401200 ·Status: COMPLETED ·Phase: NA
-
Evaluation of PEEK Versus Titanium Bar Attachments With Implant Assisted Mandibular Complete Overdenture Fabricated by CAD/CAM Technology
NCT07262307 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of Oral Health-Related Quality of Life In Patients With Conventional Complete Dentures Versus Mini-Implant Retained Overdentures: A Randomized Clinical Trial
NCT07080164 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparative Evaluation of Masticatory Efficiency of Implant Supported Overdenture
NCT05877092 ·Status: COMPLETED ·Phase: NA
-
Oral Health Related Quality of Life and Peri-implant Condition in Single Implant Overdenture
NCT02861313 ·Status: COMPLETED ·Phase: NA
-
A Study Comparing Two Different Denture Base Materials in Implant Retained Overdentures
NCT07271641 ·Status: COMPLETED ·Phase: NA
-
Single-retainer Lithium Di-silicate Versus Zirconia Resin Bonded Bridge for Replacement of an Anterior Missing Tooth.
NCT05861921 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Masticatory Performance and Patient Satisfaction for Conventional and 3D Printed Implant Overdentures
NCT06148727 ·Status: COMPLETED ·Phase: NA
-
Comparing Impression Techniques for Maxillary Complete Denture Retention
NCT06497621 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
3D Integration of Facial , Intraoral Scanning and CBCT on Patient Satisfaction and Occlusion of Temporary, Permanent Implant Supported Prosthesis
NCT06846372 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparing Cobalt-Chromium Versus PEEK Secondary Telescopic Crowns on Implant Retained Mandibular Overdenture.
NCT06637930 ·Status: COMPLETED ·Phase: NA
-
PeriImplant Soft Tissue and Marginal Bone Loss of Single Implant Mandibular Overdenture
NCT02881905 ·Status: UNKNOWN ·Phase: NA
-
Edentulous Maxilla Opposed by 2-implant Mandibular Overdenture?
NCT06050213 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of Fully Guided Versus Half Guided Implant
NCT06542562 ·Status: COMPLETED ·Phase: NA
-
3D-printed Crowns Versus Prefabricated Stainless-Steel Crowns for Intermediate Restoration of Compromised First Permanent Molars
NCT06047925 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Minimally Invasive Treatment of Worn Dentition With Innovative CAD-CAM Composites
NCT02828696 ·Status: UNKNOWN ·Phase: NA