Clinical Performance and Stability of Different Types of Implant Supported Overdenture
NCT05972538 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 6
Last updated 2023-08-02
Summary
A Total number of 36 implants were installed in 6 patients having mandibular single denture.
The patients were divided into two groups according to the definitive prosthesis.
Group I received ball and socket retained mandibular implant overdenture while Group II received cement retained implant supported fixed bridges.
Conditions
- Complete Edentulism
Interventions
- DEVICE
-
Osstell ( Osstell AB, Goteborg, Sweden).
Implant stability were assessed on 15, 30,60 and 90 days of prosthesis delivery
- DEVICE
-
periodontal probe (Vivacare, TPS, Vivadent, Schaan, Lichtenstein
Clinical evaluation included assessment of pocket depth, plaque index and bleeding on probing) around the implant abutments on 15, 30,60 and 90 days of prosthesis delivery
- OTHER
-
questionnaire for patient satisfaction
A questionnaire was used to evaluate patient satisfaction on 90 days at the end of follow up period.
Sponsors & Collaborators
-
National Research Centre, Egypt
lead OTHER
Principal Investigators
-
Asmaa N. Elboraey, Asso, Prof · National Research Centre, Egypt
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Max Age
- 60 Years
- Sex
- MALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-04-01
- Primary Completion
- 2023-07-01
- Completion
- 2023-07-05
Countries
- Egypt
Study Locations
More Related Trials
-
Prosthetic Maintenance of Two Implant-Retained Overdentures Reinforced With PEKK Versus Co-Cr Frameworks
NCT06219811 ·Status: COMPLETED ·Phase: NA
-
Implant Stability Changes Using Underdrilling Versus Osseodensification Protocols for Posterior Dental Implants
NCT06989684 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparative Evaluation of Masticatory Efficiency of Implant Supported Overdenture
NCT05877092 ·Status: COMPLETED ·Phase: NA
-
Effect of Implant Position on Clinical Outcomes
NCT06166316 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Digital Versus Conventional Techniques for Construction of Mandibular Implant Retained Overdenture
NCT06139003 ·Status: COMPLETED ·Phase: NA
-
Mandibular Overdentures Retained by Conventional or Mini Implants
NCT01411683 ·Status: COMPLETED ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Occlusion and Disocclusion Time in Immediately Loaded Overdentures Supported by Two Splinted Versus Non Splinted Interforaminal Implants
NCT06376019 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction and Retention in Implant Supported Telescopic Overdenture With Different Copings
NCT04032223 ·Status: UNKNOWN ·Phase: NA
-
Effect of Two Different Digital Construction Techniques of Implant-assisted Overdentures
NCT06720389 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Effect of Osseodensefication Technique Versus Conventional Implant Drilling Technique in Implant Supported Mandibular Overdenture
NCT06590753 ·Status: RECRUITING ·Phase: NA
-
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815 ·Status: COMPLETED ·Phase: NA
-
Effect of Digital Versus Static Jaw Relation Record on Crestal Bone Changes Around Implants Supporting Maxillary Single Overdenture
NCT06965517 ·Status: COMPLETED ·Phase: NA
-
Prosthetic and Biological Complications of Implant Supported Prostheses
NCT05297253 ·Status: COMPLETED
-
Mandibular Implant Overdenture With OT Cap Bar vs Bar Attachment
NCT07067190 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Milled in Versus Round Bar for Mini-implant Retained Mandibular Overdentures
NCT06185283 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction and OHRQoL In Removable Versus Fixed Implant Prostheses
NCT04694209 ·Status: COMPLETED ·Phase: NA
-
Occlusal Forces and Muscle Activity in Fixed Versus Removable Mandibular Implant Supported Overdenture
NCT05949151 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction With Different Numbers of Implants
NCT05882617 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction , Prosthetic Complications and Clinical Outcomes of PEEK Composite Versus Titanium Zirconium
NCT06111391 ·Status: COMPLETED ·Phase: NA
-
Digital Versus Conventional Full-arch Implant Impression in Maxillary Screw- Retained Implant Prosthesis
NCT05709236 ·Status: COMPLETED ·Phase: NA
-
Effect of Mini Implants Supported Over Dentures Versus Conventional Implant After Bone Expansion
NCT03326453 ·Status: UNKNOWN ·Phase: NA
-
Patient Satisfaction and Oral Health-Related Quality of Life of Quadrilateral Versus Bilateral Linear Bar Designs for Four Implant Implant-Assisted Complete Mandibular Overdenture Regarding Peri-Implant Crestal Bone Loss
NCT06673173 ·Status: COMPLETED ·Phase: NA
-
Mandibular Overdentures Retained by Four Locator Attachments Versus Four-Implant Bar Attachments
NCT07093853 ·Status: RECRUITING
-
Comparative Study of Mandibular Dentures Immediately Loaded on Implants or Mini-implants
NCT03866031 ·Status: COMPLETED ·Phase: NA