The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required.

Conditions

  • Airway Morbidity
  • Intubation Complication
  • Tracheal Intubation Morbidity
  • Anesthesia Intubation Complication
  • Failed or Difficult Intubation, Sequela

Interventions

DEVICE

ZU-bend stylet

Laryngoscopy and intubation after induction of anesthesia will be done using the GlideScope and the ZU-bend stylet. The ZU-bend is a specific shaping technique of the intubating stylet that is closely related to the GlideScope blade curvature. Zu-bend stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.

DEVICE

GlideScope

Laryngoscopy and intubation after induction of anesthesia will be done using the the GlideScope technique. The GlideScope is a video laryngoscope that provides a real-time view of the airway and tube placement during intubation. GlideScope is removed after DLT is in the trachea, and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.

DEVICE

GlideRite stylet

Laryngoscopy and intubation after induction of anesthesia will be done with the GlideScope using the GlideRite stylet. The GlideRite stylet is specifically designed to work with the GlideScope and provides the necessary rigidity and curvature to an otherwise flexible tube. GlideRite stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.

DEVICE

Macintosh blade

Direct laryngoscopy and intubation after induction of anesthesia will be done with the Macintosh blade and a regular double-lumen endobronchial tube (DLT) stylet. The Macintosh blade is used to facilitate visualization of the larynx during double or single lumen endobronchial tube placement. After intubation the Macintosh laryngoscope is removed and the confirmation of the successful placement of the double-lumen endobronchial tube in done in the standard fashion.

DEVICE

Regular Double-lumen endobronchial tube (DLT) Stylet

Direct laryngoscopy and intubation after induction of anesthesia will be done with a regular double-lumen endobronchial tube (DLT) stylet and the Macintosh blade. The DLT stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, Macintosh laryngoscope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.

Sponsors & Collaborators

  • Emory University

    lead OTHER

Principal Investigators

  • Igor Zhukov, MD · Emory University

Study Design

Allocation
RANDOMIZED
Purpose
HEALTH_SERVICES_RESEARCH
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2015-07-31
Primary Completion
2017-07-27
Completion
2017-07-27