Comparison of Double Lumen Tube Placement Techniques
NCT02495259 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 19
Last updated 2018-07-27
Summary
The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required.
Conditions
- Airway Morbidity
- Intubation Complication
- Tracheal Intubation Morbidity
- Anesthesia Intubation Complication
- Failed or Difficult Intubation, Sequela
Interventions
- DEVICE
-
ZU-bend stylet
Laryngoscopy and intubation after induction of anesthesia will be done using the GlideScope and the ZU-bend stylet. The ZU-bend is a specific shaping technique of the intubating stylet that is closely related to the GlideScope blade curvature. Zu-bend stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
- DEVICE
-
GlideScope
Laryngoscopy and intubation after induction of anesthesia will be done using the the GlideScope technique. The GlideScope is a video laryngoscope that provides a real-time view of the airway and tube placement during intubation. GlideScope is removed after DLT is in the trachea, and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
- DEVICE
-
GlideRite stylet
Laryngoscopy and intubation after induction of anesthesia will be done with the GlideScope using the GlideRite stylet. The GlideRite stylet is specifically designed to work with the GlideScope and provides the necessary rigidity and curvature to an otherwise flexible tube. GlideRite stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
- DEVICE
-
Macintosh blade
Direct laryngoscopy and intubation after induction of anesthesia will be done with the Macintosh blade and a regular double-lumen endobronchial tube (DLT) stylet. The Macintosh blade is used to facilitate visualization of the larynx during double or single lumen endobronchial tube placement. After intubation the Macintosh laryngoscope is removed and the confirmation of the successful placement of the double-lumen endobronchial tube in done in the standard fashion.
- DEVICE
-
Regular Double-lumen endobronchial tube (DLT) Stylet
Direct laryngoscopy and intubation after induction of anesthesia will be done with a regular double-lumen endobronchial tube (DLT) stylet and the Macintosh blade. The DLT stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, Macintosh laryngoscope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
Sponsors & Collaborators
-
Emory University
lead OTHER
Principal Investigators
-
Igor Zhukov, MD · Emory University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- HEALTH_SERVICES_RESEARCH
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-07-31
- Primary Completion
- 2017-07-27
- Completion
- 2017-07-27
Countries
- United States
Study Locations
More Related Trials
-
GlideScope Groove Versus Macintosh Blade for Double-Lumen Endotracheal Tube Intubation
NCT01488695 ·Status: WITHDRAWN ·Phase: NA
-
Comparison of GlideScope-Specific Rigid Stylet to Standard Malleable Stylet for GlideScope Intubation by Novice Operators
NCT00884754 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Glidescope and Macintosh Laryngoscope for Double Lumen Endotracheal Tube Intubation
NCT01404780 ·Status: COMPLETED ·Phase: NA
-
Videolaryngoscopes for Double Lumen Tube Intubations in Simulated Easy and Difficult Airway
NCT02640196 ·Status: COMPLETED ·Phase: NA
-
GlideScope Versus Direct Laryngoscope for Emergency Intubation
NCT01235065 ·Status: COMPLETED ·Phase: NA
-
Videolaryngoscopes for Double Lumen Tube Intubations
NCT02305667 ·Status: COMPLETED ·Phase: NA
-
The Comparison of Glidescope® and the Direct Laryngoscopy in the Insertion of the Double Lumen Endotracheal Tube
NCT01424605 ·Status: COMPLETED ·Phase: NA
-
A Clinical Comparison of Two New Bronchial Blockers vs. Double Lumen Tubes in One Lung Ventilation
NCT02983149 ·Status: COMPLETED ·Phase: NA
-
Fiberoptic Bronchoscope of Double Lumen Tube and Single Lumen Tube in Patients With Semi-regid Neck Collar.
NCT03392766 ·Status: COMPLETED ·Phase: NA
-
The Effects of Flexible Intubating Stylet in the Accurate Placement of Double-lumen Endobronchial Tube
NCT02364622 ·Status: COMPLETED ·Phase: NA
-
GlideScope® vs GlideScope® + aScope® for Managing Difficult Airways.
NCT02627755 ·Status: UNKNOWN ·Phase: NA
-
Comparison of iLTS-D® and ILMA® for Intubation With Fiberoptic Control
NCT02922595 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Requirement of External Laryngeal Manipulation in Double Lumen Tube Insertion With McGrath Laryngoscope vs Macintosh Laryngoscope. A Randomized Control Trial
NCT06525779 ·Status: COMPLETED ·Phase: NA
-
Comparison of Video Laryngoscopy With Rigid Stylet vs Video Laryngoscopy With the TCI Articulating Introducer for Endotracheal Intubation in Simulated Difficult Airways
NCT06115694 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Laryngoscope Versus CMAC for Endotracheal Intubation in Patients Undergoing Emergent Airway Management
NCT01710891 ·Status: COMPLETED ·Phase: PHASE4
-
Examining the Ease of Intubation Using the Parker Flex-Tip® or a Standard Endotracheal Tube
NCT01263873 ·Status: COMPLETED ·Phase: NA
-
Insertion Time Over Fiberoptic Bronchoscope of Double Lumen Tube and Single Lumen Tube
NCT03173443 ·Status: COMPLETED ·Phase: NA
-
Endotrol-tracheal Tube Assisted Endotracheal Intubation During Video Laryngoscopy
NCT01099969 ·Status: COMPLETED ·Phase: NA
-
Does the Use of the GlideRite® Endotracheal Tube in Combination With the I-gel® Improve Intubation Success Rate?
NCT01265862 ·Status: COMPLETED ·Phase: NA
-
Comparison of Intubation Conditions of the Articulating Stylet and Intubating Stylet Guided Videolaryngoscopy
NCT02805569 ·Status: COMPLETED ·Phase: NA
-
Comparison of 3 Direct Laryngoscopes for Tracheal Intubation in Patients Undergoing Lumbar Spine Surgery
NCT02955511 ·Status: TERMINATED ·Phase: NA
-
Measurement of Forces Applied Using a Macintosh Direct Laryngoscope Compared to GlideScope Video Laryngoscope
NCT01814176 ·Status: COMPLETED ·Phase: NA
-
Comparison of Endotracheal Intubation Over the Aintree Via the I-gel and Laryngeal Mask Airway Supreme
NCT02476565 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Video and Macintosh Laryngoscope in Patients Who May be Difficult to Intubate
NCT00178555 ·Status: COMPLETED ·Phase: PHASE4
-
A Comparison of Tracheal Intubation Using the Totaltrack vs the Macintosh Laryngoscope in Routine Airway Management
NCT02395445 ·Status: COMPLETED ·Phase: NA