The Effects of Flexible Intubating Stylet in the Accurate Placement of Double-lumen Endobronchial Tube
NCT02364622 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 120
Last updated 2015-02-18
Summary
The purpose of this study is to determine whether using the flexible Trachway(R) intubating stylet could facilitate and promote the accurate placement of double-lumen endobronchial tube.
Conditions
- Intubation Complication
- Intubation, Difficult
Interventions
- DEVICE
-
Tranditional fiberoptic bronchoscopy
The accurate placement of left-sided DLT into the left main bronchus was facilitated by tranditional fiberoptic bronchoscopy.
- DEVICE
-
Modified fiberoptic bronchoscopy
The accurate placement of left-sided DLT into the left main bronchus was facilitated by modified fiberoptic bronchoscopy
- DEVICE
-
Flexible Trachway intubating stylet
The accurate placement of left-sided DLT into the left main bronchus was faciliated by using flexible Trachway intubating stylet.
Sponsors & Collaborators
-
Kaohsiung Medical University Chung-Ho Memorial Hospital
lead OTHER
Principal Investigators
-
Hung-Te Hsu, MD · Department of Anesthesia, Kaohsiung Medical University Chung-Ho Memorial Hospital
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2013-10-31
- Primary Completion
- 2014-12-31
- Completion
- 2014-12-31
Countries
- Taiwan
More Related Trials
-
Stylet Shape in Simulated Endotracheal Intubation by Medical Students
NCT06525662 ·Status: RECRUITING ·Phase: NA
-
The Pretreatment of a Left-sided Double-lumen Tube to Prevent Its Misplacement to the Right Mainstem Bronchus
NCT01818128 ·Status: COMPLETED ·Phase: NA
-
Comparison of Different Bending Mode for Double-lumen Endotracheal Tube Intubation
NCT01605591 ·Status: COMPLETED ·Phase: NA
-
The Effectiveness of Foley Airway Stylet Tool on Proseal LMA Insertion
NCT02048657 ·Status: COMPLETED ·Phase: NA
-
Technique Using Trachway to Safely Navigate Endotracheal Tube Through Nasal Cavity
NCT03097913 ·Status: COMPLETED
-
The Comparison of Glidescope® and the Direct Laryngoscopy in the Insertion of the Double Lumen Endotracheal Tube
NCT01424605 ·Status: COMPLETED ·Phase: NA
-
Comparison of Different Tools to Facilitate Nasotracheal Tube Placement Under Video-laryngoscope Use
NCT03086798 ·Status: COMPLETED ·Phase: NA
-
Identification of Morphological Characteristics to Predict Difficult Endotracheal Intubation Using a Flexible Fiberscope
NCT02769819 ·Status: COMPLETED ·Phase: NA
-
Double Lumen Tube Positioning With Bonfils Fiberoptic Stylet: Prospective Observational Study in 30 Adult Patients
NCT03982745 ·Status: UNKNOWN
-
The Effectiveness of Using Bougie or Cooled Nasogastric Tube to Facilitate Nasotracheal Intubation
NCT04087837 ·Status: COMPLETED ·Phase: NA
-
Insertion Time Over Fiberoptic Bronchoscope of Double Lumen Tube and Single Lumen Tube
NCT03173443 ·Status: COMPLETED ·Phase: NA
-
Placement of the Double-Lumen Tube Without Fiberoptic Bronchoscope Assistance
NCT02943928 ·Status: COMPLETED ·Phase: NA
-
Fingers Hook Technique to Facilitate Nasotracheal Intubation
NCT03086668 ·Status: COMPLETED ·Phase: NA
-
Comparison of Double Lumen Tube Placement Techniques
NCT02495259 ·Status: TERMINATED ·Phase: NA
-
Standard Versus Flexible Tip Bougie for Videolaryngoscopy
NCT04973176 ·Status: COMPLETED ·Phase: NA
-
Flexible Tip Bougie vs Tube With Stylet for Intubation With Videolaryngoscopy.
NCT05429125 ·Status: RECRUITING ·Phase: NA
-
Comparison of Double-lumen Tube Intubation Between Fiberoptic Bronchoscopy and Video Laryngoscope
NCT07241208 ·Status: RECRUITING ·Phase: NA
-
Comparison of GlideScope-Specific Rigid Stylet to Standard Malleable Stylet for GlideScope Intubation by Novice Operators
NCT00884754 ·Status: COMPLETED ·Phase: NA
-
A Predictive Model for Difficult Intubation
NCT02944305 ·Status: COMPLETED
-
"Neutral Head Position" and "Head-lift Position" for Orotracheal Intubation With "Trachway" Intubating Stylet in Adults
NCT02578992 ·Status: COMPLETED ·Phase: NA
-
Analysis of Breath Sound During Thoracic Surgery
NCT05250635 ·Status: UNKNOWN
-
Endotracheal Tube (ETT) 180: Stylet-loaded Endotracheal Tube Rotation Before Insertion
NCT06231342 ·Status: RECRUITING ·Phase: NA
-
Examining the Ease of Intubation Using the Parker Flex-Tip® or a Standard Endotracheal Tube
NCT01263873 ·Status: COMPLETED ·Phase: NA
-
Assessment of a Novel Tracheostomy Tie
NCT02820181 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Bending Angles for Nasotracheal Intubation With a Malleable Vedio Stylet
NCT04459481 ·Status: COMPLETED ·Phase: NA