Comparison of the Glidescope and Macintosh Laryngoscope for Double Lumen Endotracheal Tube Intubation
NCT01404780 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 70
Last updated 2013-02-22
Summary
Patients undergoing chest surgery often require insertion of a breathing tube (double lumen tube) after they are unconscious. The double lumen tube enables the anaesthetist to ventilate (assist breathing) one lung at a time. The other lung is partially deflated to enable enough space for the surgeon to perform the procedure. The breathing tube is inserted with a laryngoscope (blade with a light at the end) so the vocal cords can be seen. This is standard medical practise. Two laryngoscopes are commonly used at Toronto General Hospital to insert the tube. The Macintosh laryngoscope has been is use for over 50 years and the Glidescope for over 10 years. Both devices have been extensively researched for single lumen tubes insertion and found to be very safe and effective. Research is limited to say which of the two laryngoscope is the most effective for double lumen tubes.
Conditions
Interventions
- DEVICE
-
GlideScope (GVL)
The Glidescope (GVL) has not been extensively studied for double lumen tube intubation. The GVL may be particularly useful for patients with difficult airways as it has a camera attached to the blade.
- DEVICE
-
Macintosh Direct Laryngoscope (MDL)
Current standard of care at UHN for 50 years
Sponsors & Collaborators
-
University Health Network, Toronto
lead OTHER
Principal Investigators
-
Adriaan Van Rensburg, MD · University Health Network, Toronto General Hospital
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-06-30
- Primary Completion
- 2012-08-31
- Completion
- 2013-02-28
Countries
- Canada
Study Locations
More Related Trials
-
A Clinical Comparison of Two New Bronchial Blockers vs. Double Lumen Tubes in One Lung Ventilation
NCT02983149 ·Status: COMPLETED ·Phase: NA
-
Application of Visual Laryngeal Mask Airway Combined With Endotracheal Intubation in General Anesthesia
NCT04719767 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Simultaneous Endotracheal Tube Insertion With GlideScope Use
NCT02787629 ·Status: COMPLETED ·Phase: NA
-
Comparison of Early Endotracheal Tube Insertion With GlideScope Use
NCT01564082 ·Status: COMPLETED ·Phase: NA
-
Measurement of Forces Applied Using a Macintosh Direct Laryngoscope Compared to GlideScope Video Laryngoscope
NCT00992628 ·Status: COMPLETED ·Phase: NA
-
GlideScope Versus Direct Laryngoscope for Emergency Intubation
NCT01235065 ·Status: COMPLETED ·Phase: NA
-
Optimal Laryngoscopic View to Enable GlideScope-assisted Tracheal Intubation
NCT02144207 ·Status: COMPLETED ·Phase: NA
-
Videolaryngoscopes for Double Lumen Tube Intubations in Simulated Easy and Difficult Airway
NCT02640196 ·Status: COMPLETED ·Phase: NA
-
GlideScope®Video Laryngoscope for Difficult Intubation: Implication of the Size of Blade
NCT01616771 ·Status: COMPLETED ·Phase: NA
-
Does the Use of the GlideRite® Endotracheal Tube in Combination With the I-gel® Improve Intubation Success Rate?
NCT01265862 ·Status: COMPLETED ·Phase: NA
-
Laryngoscope Prototype Tested Against the Traditional Macintosh Blade
NCT00378170 ·Status: UNKNOWN ·Phase: NA
-
Comparison of the Macintosh, King Vision®, Glidescope® and AirTraq® Laryngoscopes in Routine Airway Management
NCT01914523 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
A Comparison of Video Laryngoscopes and the Direct Laryngoscope in Simulated Normal and Difficult Infant Airway.
NCT03230422 ·Status: COMPLETED ·Phase: NA
-
Comparison of Double Lumen Tube Placement Techniques
NCT02495259 ·Status: TERMINATED ·Phase: NA
-
Double-lumen Tube Intubation Technique to Reduce Laryngeal Injuries
NCT01441362 ·Status: COMPLETED ·Phase: NA
-
The Comparison of Glidescope® and the Direct Laryngoscopy in the Insertion of the Double Lumen Endotracheal Tube
NCT01424605 ·Status: COMPLETED ·Phase: NA
-
GlideScope® vs GlideScope® + aScope® for Managing Difficult Airways.
NCT02627755 ·Status: UNKNOWN ·Phase: NA
-
Comparison of GlideScope-Specific Rigid Stylet to Standard Malleable Stylet for GlideScope Intubation by Novice Operators
NCT00884754 ·Status: COMPLETED ·Phase: NA
-
Glidescope Videolaryngoscope and Macintosh Laryngoscope in Children
NCT03326882 ·Status: COMPLETED ·Phase: NA
-
Comparison Study in Adult Surgical Patients of 5 Airway Devices
NCT00602979 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Video and Macintosh Laryngoscope in Patients Who May be Difficult to Intubate
NCT00178555 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of GlideScope Specific Stylet to Malleable Stylet for GlideScope Intubation
NCT00434720 ·Status: COMPLETED ·Phase: NA
-
McGrath Mac Videolaryngoscope Versus Macintosh Laryngoscope for Orotracheal Intubation in Critical Care Unit
NCT02413723 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Types of Videolaryngoscope and Direct Laryngoscope in Expected Non-difficult Airway Patients
NCT04185675 ·Status: UNKNOWN ·Phase: NA
-
Comparison Of Videolaryngoscopes In Double Lumen Tube
NCT03826706 ·Status: UNKNOWN ·Phase: NA