3D Printing Orientation and Film Thickness for Maxillary Complete Dentures

NCT07740278 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 15

Last updated 2026-07-31

No results posted yet for this study

Summary

This randomized crossover clinical trial aims to evaluate the effect of different three-dimensional (3D) printing orientations and layer thicknesses on the trueness, dimensional accuracy, and patient satisfaction of maxillary complete dentures in completely edentulous patients. Each participant will receive two maxillary 3D-printed complete dentures fabricated using the same printing orientation (0°, 45°, or 90°) with two different layer thicknesses (50 μm and 100 μm) in a crossover sequence. The study will compare the influence of these printing parameters on denture accuracy and patient-reported outcomes to identify the optimal 3D printing settings for complete denture fabrication.

Conditions

  • Complete Edentulism
  • Maxillary Complete Denture Rehabilitation
  • Prosthodontics
  • 3d Printing
  • Digital Denture

Interventions

DEVICE

0° 3D-Printed Maxillary Complete Denture

Participants will receive maxillary complete dentures fabricated using a 0° three-dimensional (3D) printing orientation. Each participant will receive two dentures printed with 50 μm and 100 μm layer thicknesses in a crossover sequence. This intervention is intended to evaluate the effect of the 0° build orientation on denture trueness, dimensional deviation, and patient satisfaction.

DEVICE

45° 3D-Printed Maxillary Complete Denture

Participants will receive maxillary complete dentures fabricated using a 45° three-dimensional (3D) printing orientation. Each participant will receive two dentures printed with 50 μm and 100 μm layer thicknesses in a crossover sequence. This intervention is intended to evaluate the effect of the 45° build orientation on denture trueness, dimensional deviation, and patient satisfaction.

DEVICE

90° 3D-Printed Maxillary Complete Denture

Participants will receive maxillary complete dentures fabricated using a 90° three-dimensional (3D) printing orientation. Each participant will receive two dentures printed with 50 μm and 100 μm layer thicknesses in a crossover sequence. This intervention is intended to evaluate the effect of the 90° build orientation on denture trueness, dimensional deviation, and patient satisfaction.

Sponsors & Collaborators

  • Tanta University

    lead OTHER

Principal Investigators

  • noha Mamdouh Hamed elkafoury, BDS, MSc · Faculty of Dentistry, Tanta University, Egypt

Study Design

Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
NONE
Model
CROSSOVER

Eligibility

Min Age
50 Years
Max Age
70 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2026-08-08
Primary Completion
2027-02-01
Completion
2027-03-01

Countries

  • Egypt

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT07740278 on ClinicalTrials.gov