Bone Metabolism in Patients Treated With 3d Printed Aligners Versus Thermoformed Aligners
NCT07617571 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2026-06-01
Summary
Background: Orthodontic forces induce tissue reactions by triggering perturbations from orthodontic appliances, which lead to the modelling and remodelling of alveolar bone. Despite the growing popularity of 3D-printed aligners, no studies have compared their effects on bone metabolism in comparison with thermoformed aligners. Aim: This study aims to assess bone metabolism in patients undergoing treatment with 3D-printed aligners versus thermoformed aligners.
Conditions
- Bone Metabolism
- Orthodontic Aligners
Interventions
- OTHER
-
Directly printed aligners using Tera Harz TA28 resin
Aligners will be digitally designed using the latest version of ArchForm software for segmentation of dental arches, virtual tooth movement planning and generation of sequential treatment stages, the finalized setups will be exported as STL files.
- OTHER
-
PETG thermoplastic sheets
Aligners were digitally designed using the latest version of ArchForm software .The 3D-printed resin models which were used as a mold for aligner thermoforming, were fabricated by Anycubic Photon Mono M5s (12K resolution) (Anycubic, China) 3D printing machine.
Sponsors & Collaborators
-
Alexandria University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 25 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-06-01
- Primary Completion
- 2026-06-30
- Completion
- 2026-07-01
Countries
- Egypt
Study Locations
More Related Trials
-
Bone Level Changes Using Clear Aligners Compared to Fixed Appliances in Non-Extraction Treatment of Adults
NCT07716007 ·Status: COMPLETED ·Phase: NA
-
AMOUNT OF INTRAORAL OCCLUSAL ADJUSTMENTS IN OCCLUSAL SPLINTS FABRICATED USING FULLY DIGITAL VERSUS COMBINED DIGITAL WORKFLOW IN TMD PATIENTS
NCT06752200 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Performance of Direct-Printed Versus Thermoformed Aligners
NCT07637227 ·Status: RECRUITING ·Phase: NA
-
Crown Movement in Cases Treated With Direct Printed Aligners
NCT07273435 ·Status: RECRUITING ·Phase: NA
-
Shape Memory Orthodontic Aligners
NCT07431333 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Dentoalveolar Changes of Clear Aligners Versus Fixed Orthodontic Appliances on Skeletal Class I Non-extraction Patients With Dental Crowding
NCT07090746 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Indirect Bonding Accuracy of 3D Printed Digital Transfer Trays
NCT06167278 ·Status: RECRUITING ·Phase: NA
-
Biological Reaction of Direct 3d Printed Retainers
NCT07098325 ·Status: RECRUITING ·Phase: NA
-
3D-Printed Vs Thermoformed Retainers: Comparison of Post-Treatment Stability, Changes in Mechanical Properties and Patients' OHRQoL
NCT05968625 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Segmented Versus Full Arch Three Dimensionally Printed Transfer Tray for Orthodontic Indirect Bonding
NCT03564717 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of 3DPrinted Windowed Bracket- Positioning Guide Compared To Thermoformed Indirect Bonding Tray
NCT03585881 ·Status: UNKNOWN ·Phase: NA
-
Smile Arc Assessment in Orthodontic Patients Following Smile Arc Protection VS MBT Placement Guide Bonding Strategies
NCT05277506 ·Status: UNKNOWN ·Phase: NA
-
Comparison of One-Step and Two-Step Light Curing of Bonding Agents and Composite in Orthodontics
NCT07491796 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Three-Dimensional Printed Orthodontic Molar Distalizer
NCT07191158 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Efficiency for Three Different Aligning Archwires During Initial Orthodontic Leveling
NCT04387578 ·Status: COMPLETED ·Phase: NA
-
Validation of AI-Based Cephalometric Analysis in Orthodontics
NCT07315152 ·Status: NOT_YET_RECRUITING
-
Evaluation of Smile Esthetics in Orthodontically Treated Patients With Bimaxillary-dentoalveolar Protrusion
NCT03074370 ·Status: UNKNOWN
-
Evaluation of 3D Printed Modified Twin Block for Correction of Skeletal Class II Malocclusion in Growing Females
NCT04028661 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Effectiveness of Different Esthetic Orthodontic Appliances
NCT06803433 ·Status: COMPLETED ·Phase: NA
-
Prefabricated Versus 3D-Printing Myofunctional Appliances
NCT04810286 ·Status: UNKNOWN ·Phase: NA
-
Skeletal and Dentoalveolar Effects of Functional Clear Aligner Therapy in Growing Patient With Skeletal Class III Malocclusion
NCT07703007 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
3D Printed vs. Milled Occlusal Splints in Dentistry
NCT07236294 ·Status: COMPLETED
-
Development of Biofunctional 3D-Printed Orthodontic Aligners With Antimicrobial and Remineralizing Properties
NCT07603427 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Precision Orthodontics: Virtual Treatment Planning for Orthodontic Braces
NCT04002999 ·Status: UNKNOWN ·Phase: NA
-
Dentofacial Effects Of Two Non-Compliance Appliances In The Treatment Of Growing Skeletal Class III Patients
NCT04825951 ·Status: COMPLETED ·Phase: NA