Evaluation of Fixed Mandibular Retainer Using 3D Printed Positioning Tray Versus Direct Bonding Technique
NCT03572179 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2021-09-05
Summary
Although there are many studies in the literature concerning methods of bonding of mandibular retainers whether directly or indirectly, there is a very limited evidence regarding their chair side time and bond failure. Also there are scarce data on fixed mandibular retainers bonded using 3D printed positioning tray.Thus, conducting a well-designed randomized clinical trial evaluating the chair side time and bond failure of 3d printed positioning tray and direct bonding method of fixed mandibular retainer.Null hypothesis is thatThe time needed for direct indirect bonding using 3D digital positioning tray of a mandibular fixed retainer is shorter than the time needed for direct bonding, and there is no difference in failures between the 2 bonding methods
Conditions
- Orthodontic Appliance Complication
Interventions
- DEVICE
-
3d printed positioning tray
3d printed positioning tray for lingual fixed retainer placement in treatment group
Sponsors & Collaborators
-
Raghda Alaa
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2019-03-01
- Primary Completion
- 2019-03-01
- Completion
- 2020-03-28
Countries
- Egypt
Study Locations
More Related Trials
-
Comparison Between Digital 3D Printed Transfer Tray Versus Thermoformed Transfer Tray for Indirect Bonding
NCT03363607 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of 3DPrinted Windowed Bracket- Positioning Guide Compared To Thermoformed Indirect Bonding Tray
NCT03585881 ·Status: UNKNOWN ·Phase: NA
-
AMOUNT OF INTRAORAL OCCLUSAL ADJUSTMENTS IN OCCLUSAL SPLINTS FABRICATED USING FULLY DIGITAL VERSUS COMBINED DIGITAL WORKFLOW IN TMD PATIENTS
NCT06752200 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Treatment of Skeletal Class III Malocclusion Using Orthodontic Removable Traction Appliance
NCT03172442 ·Status: COMPLETED ·Phase: NA
-
Retentive Capacity of Bonded Retainer Vs Vacuum-formed and Combined Bonded-vacuum Retainers
NCT06476574 ·Status: RECRUITING ·Phase: NA
-
Comparison of the Effect of Two Types of Fixed Retainers on the Health of the Gums
NCT01314729 ·Status: UNKNOWN ·Phase: PHASE3
-
Evaluation of the Effects of Flat and Modified Inclined Fixed Anterior Bite Planes on Mandibular Position in Growing Females With Skeletal Class 2 Malocclusion Due to Mandibular Deficiency and Deep Bite
NCT03308175 ·Status: UNKNOWN ·Phase: NA
-
3D Printed vs. Milled Occlusal Splints in Dentistry
NCT07236294 ·Status: NOT_YET_RECRUITING
-
3D-Printed Vs Thermoformed Retainers: Comparison of Post-Treatment Stability, Changes in Mechanical Properties and Patients' OHRQoL
NCT05968625 ·Status: UNKNOWN ·Phase: NA
-
Treatment of Class III Malocclusion Using Modified Fixed Mandibular Retractor Appliance
NCT03354442 ·Status: COMPLETED ·Phase: NA
-
Vacuum-formed Retainer Versus Bonded Retainer to Prevent Relapse After Orthodontic Treatment
NCT03070444 ·Status: COMPLETED ·Phase: NA
-
Chairside Time and Accuracy of Indirect Bonding of Orthodontic Attachments Using Double Versus Single Transfer Tray
NCT03362034 ·Status: UNKNOWN ·Phase: NA
-
Mandibular First Molar Distalization
NCT04229797 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of Digital Mandibular Repositioning in Occlusal Reconstruction for Patients With Disc Displacement
NCT07345104 ·Status: COMPLETED ·Phase: NA
-
Comparative Evaluation Of Two Bone-Anchored Maxillary Molar Distalization Appliances: Direct Versus Indirect Anchorage
NCT06507319 ·Status: RECRUITING ·Phase: NA
-
The Effect of Different Force Magnitudes on Maxillary Posterior Segment Intrusion
NCT02901678 ·Status: COMPLETED ·Phase: NA
-
Indirect Bonding Accuracy of 3D Printed Digital Transfer Trays
NCT06167278 ·Status: RECRUITING ·Phase: NA
-
Transfer Accuracy of 3D-printed Indirect Bonding Trays
NCT04683874 ·Status: COMPLETED ·Phase: NA
-
Occlusal Stabilization Splints Equilibrated by Different Techniques and Their Effect on TMD
NCT04661670 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Bracket Bonding Variables Using 3D Printed Bonding Guide Versus Digital Indirect Bonding
NCT05193708 ·Status: COMPLETED ·Phase: NA
-
RCT for the Effectiveness of 3 Orthodontic Retention Schemes on Post-treatment Stability and Gingival Recession
NCT02742493 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Comparative Study Using Two 3D Printed Occlusal Splints for Patients With Tempromandibular Disorder
NCT04455672 ·Status: UNKNOWN ·Phase: NA
-
Posterior Segment Intrusion Using Miniplates
NCT02674191 ·Status: UNKNOWN ·Phase: NA
-
Chairside Time and Bond Failure of Non Custom Versus Custom Base Orthodontic Attachments During Indirect Bonding
NCT03365232 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Conventional Versus 3D-Designed and Printed Stabilization Splints for Treatment of TMD Patients: A Randomized Clinical Trial.
NCT06781138 ·Status: COMPLETED ·Phase: NA