Impact of Local Tissue Inflammation on Intramyocardial Conduction Pathways Post Percutaneous Valve : Evaluation by Positron Emission Tomography on Exploratory Cohort
NCT05308888 · Status: UNKNOWN · Phase: PHASE2 · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2022-04-04
Summary
Aortic valve stenosis is the most common valve disease leading to surgical or percutaneous intervention in Europe and North America. Percutaneous aortic valve replacement (TAVI) is currently recommended for the management of patients with symptomatic aortic stenosis and with high; very high operative risk of aortic valve replacement surgery or intermediate operative risk of aortic valve replacement surgery after a benefit-risk assessment by a heart team and operative contraindication to conventional aortic valve replacement surgery. These indications are supported by the 2017 European Cardiology guidelines.
This technique of percutaneous arterial valve implantation is most often performed via the femoral route, under local anesthesia, with placement of a prosthetic biological valve in the aortic position, impacting it into the patient's native aortic valve.
TAVI has been shown to be superior to medical treatment in patients with a aortic valve stenosis at very high operative risk of conventional aortic valve replacement surgery. However, the occurrence of atrioventricular conduction disorders (de novo left bundle branch block (LBBB) or complete AVB) remains the most frequent complication after TAVI. Therefore, the rate of pacemaker (PM) implantation after TAVI remains high, ranging from 2% to 51%, with an average rate of 13%.
Pacemaker implantation has several deleterious effects (increased hospitalization time, desynchronization of the left ventricle by permanent right ventricular pacing, exposure of the patient to procedural complications of pacemaker placement, and possible increase in the final cost to society of the initial hospitalization.
Not all patients who received a pacemaker post TAVI implantation use their PM. The rate of Pacemaker dependency and therefore of patients who actually use their pacemaker is approximately 33-36% at 1 year after percutaneous valve implantation.
In view of all the potentially deleterious consequences of post TAVI pacemaker implantation, it is therefore necessary to know which patients really justify pacemaker implantation after percutaneous valve implantation.
The purpose of this study is to investigate diagnostic imaging criteria that may be predictive of the occurrence of intramyocardial conduction disorders post TAVI implantation. Although some patients present only transient conductive disturbances, the impact of tissue inflammation of the intramyocardial conduction pathways after TAVI remains to be understood.
Conditions
- Aortic Valve Stenosis
Interventions
- DIAGNOSTIC_TEST
-
18F-FDG PET-CT
The 18F-FDG PET-CT will be performed in the nuclear medicine department of the CHU of Brest. For this exam, the administration of 2-3 MBq/kg of 18F-FDG (\[18F\]F-fluorodeoxyglucose) will be performed to the patient in a single intravenous injection.
Sponsors & Collaborators
-
University Hospital, Brest
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-05-01
- Primary Completion
- 2023-05-01
- Completion
- 2024-05-01
Countries
- France
Study Locations
More Related Trials
-
CHART Study of Coronary CT Angiography in Coronary Artery Disease
NCT05380622 ·Status: RECRUITING
-
Non-Contrast Magnetic Resonance Angiography Assessment of Patients Referred for Transcatheter Aortic Valve Implantation
NCT02007967 ·Status: TERMINATED
-
Relationship Between Thoracic Aortic Structure Assessed B PET/CT Scan and Arterial Stiffness in Elderly Patients
NCT01963221 ·Status: COMPLETED ·Phase: NA
-
Use of Cardiac-MRI to Predict Results for People With Severe Aortic Stenosis
NCT01905852 ·Status: WITHDRAWN
-
Valvular Aortic Stenosis: Study of Myocardiac Fibrosis by Magnetic Resonance Imagery
NCT02551588 ·Status: COMPLETED
-
Biomechanical Analysis of Arterial Tissue From Patient Suffering From Peripheral Artery Disease in the Lower Limb
NCT03985150 ·Status: COMPLETED
-
Biomarkers and Mechanisms of Disease Progression and Outcome of Aortic Stenosis in Humans
NCT05851209 ·Status: NOT_YET_RECRUITING
-
Vascular Inflammation Imaging Using Somatostatin Receptor Positron Emission Tomography
NCT02021188 ·Status: COMPLETED
-
Angiogenesis and Fibrosis in Aortic Stenosis
NCT01837160 ·Status: COMPLETED
-
Cardiac MRI for Severe Aortic Stenosis
NCT01638156 ·Status: COMPLETED
-
Magnetic Resonance Adenosine Perfusion Imaging as Gatekeeper of Invasive Coronary Intervention
NCT02580851 ·Status: COMPLETED ·Phase: NA
-
Development and Validation of a Fast, Semi-Automated Hybrid Imaging Platform to Assess Coronary Atherosclerotic Plaque Morphology, Endothelial Shear Stress and Arterial Inflammation: A Proof of Principle Study (VALID-PET-CT)
NCT04205110 ·Status: COMPLETED
-
Contribution of PET/CT With Gallium 68 Citrate (68Ga-PET/CT) for the Diagnosis of Prosthetic Valve Infective Endocarditis
NCT05446376 ·Status: RECRUITING ·Phase: PHASE2
-
Validation of CMR Against Invasive Haemodynamics in Patients With HFpEF
NCT03251183 ·Status: COMPLETED
-
Comparison of Cardiac Imaging Techniques for Diagnosing Coronary Artery Disease
NCT01521468 ·Status: COMPLETED
-
Evaluate the Effectiveness and Cost of Stress Cardiac Magnetic Resonance Imaging (MRI) for Non-invasive Evaluation of Lesions Discovered on Computed Tomography Angiography (CCTA)
NCT00538460 ·Status: TERMINATED
-
Serial Coronary CTA-based Plaque Progression Detection for Management of Coronary Heart Disease
NCT06843005 ·Status: RECRUITING ·Phase: NA
-
IMAGE-Endocarditis: Resonance Magnetic Imaging at the Acute Phase of Endocarditis
NCT00144885 ·Status: COMPLETED ·Phase: NA
-
Study of Cardiac Lesions Angiogenesis by 68Ga-NODAGA-RGD Cardiac PET
NCT03809689 ·Status: TERMINATED ·Phase: NA
-
Understanding the Mechanisms of Diastolic Dysfunction
NCT03340233 ·Status: WITHDRAWN ·Phase: NA
-
Evaluation of PCD-CT Based Image Parameters in the Assessment and Quantification of Coronary Artery Disease
NCT05877768 ·Status: NOT_YET_RECRUITING
-
In Vivo Evaluation of Growth and Risk of Rupture of Dilated Ascending Aorta Using 4D Cardiac Magnetic Resonance
NCT03172390 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Fractional Flow Reserve CT (FFRCT)Scan for the Study of Coronary Vaso-motion
NCT02809157 ·Status: UNKNOWN
-
18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis
NCT04073875 ·Status: COMPLETED
-
The Prognostic Role of the Right Ventricle in Patients With Heart Failure or Congenital Heart Disease
NCT03969394 ·Status: UNKNOWN ·Phase: NA