A Technique for Border Molding in Complete Dentures Using Light-Cured
NCT04853459 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2022-03-08
Summary
Since the teeth loss leads to disability \& impairment, and teeth restoration lead to improvement in the life quality throughout the oral health improvement.
The acceptable function of a complete denture on great extent depends on impression technique which includes the maximum coverage of denture supporting areas and making a combination of managing movable soft tissues along with different kinds of impression materials and techniques for accurate reproduction of oral foundation.
Border molding considered to be as an important step in the in complete denture fabrication, since the retention of complete dentures depend on several factors, as the biological, physical and mechanical, these factors could be achieved by mean of an accurate border molding followed by an accurate final impression.
The border molding technique is the shaping of the border areas of a custom impression tray by manual or functional manipulation of the tissue adjacent to the borders in order to duplicate the size and contour of the vestibule resulting in maintains of the peripheral seal during function. This property causes the border molding process to require twenty-four insertions, namely eight in the maxilla and sixteen in the mandible causing long working time and discomfort in patients.
Hence, the material used for this technique should provide optimum working time, have adequate body, and permit the correction of border moulding by additions.
However additions if made to a single step border moulded material would again introduce all the disadvantages that are associated with sectional moulding Single-step border molding is considerably more straightforward than sectional border molding owing to the reduced number of tray insertions.
This technique is usually used with elastomeric impression materials, which may not provide sufficient time to mold and record the peripheral tissues of the denture bearing area.
The present technique uses light polymerizing tray material for molding tray borders, offering extended working time.
This is advantageous for operators with less experience, such as dental school students.
Furthermore, correction of border molding is possible with the addition of new material.
The technique uses materials that are readily available,and no special armamentarium is required.
Conditions
- Edentulous Mouth
Interventions
- PROCEDURE
-
Border modeling..Measurement
By using light cure to make border modeling in complete denture.
Sponsors & Collaborators
-
Hama University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 45 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-09-15
- Primary Completion
- 2021-12-01
- Completion
- 2022-01-01
Countries
- Syria
Study Locations
More Related Trials
-
Bone Changes Assessment in Screw-Retained Maxillary Complete Denture With Electric Welded Framework Versus Cast One
NCT04548258 ·Status: UNKNOWN ·Phase: NA
-
Assessing the Influence of Implant Scanning Techniques on the Accuracy of Maxillary Complete-Arch Digital Scans for Implant Overdentures: A Comparative Clinical Study
NCT07295899 ·Status: NOT_YET_RECRUITING
-
Evaluation of Open-face Maxillary Complete Denture for Patients With Prominent Premaxilla
NCT06209814 ·Status: COMPLETED ·Phase: NA
-
Study of Wear in Composite Resin and Reinforced Acrylic Denture Teeth Used in Complete Denture Construction for Completely Edentulous Patients
NCT04839640 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction and Microbial Changes in Complete Dentures.
NCT03043456 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of the Abutment Type Following Oral Implants in Terms of the Surrounding Bone Height
NCT05350293 ·Status: COMPLETED ·Phase: NA
-
To Evaluate the Complete Mandibular Dentures Produced Via 3D Printing in Comparison to Those Constructed From Metal-reinforced Acrylic Resin Regarding Their Retention
NCT07061860 ·Status: COMPLETED ·Phase: NA
-
Three Dimensional Printed Versus Conventional Heat Cured Acrylic Complete Denture
NCT05585008 ·Status: COMPLETED ·Phase: NA
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
NCT05999760 ·Status: COMPLETED ·Phase: NA
-
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework Versus Cast One, Patient Satisfaction Assessment.
NCT04539210 ·Status: UNKNOWN ·Phase: NA
-
Trueness of Full Arch Scans and Generated Digital Implant Models
NCT06281002 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Conventionally vs. Digitally Fabricated Complete Dentures: Clinical Treatment Outcome Differences
NCT02521935 ·Status: WITHDRAWN ·Phase: NA
-
Patient Satisfaction and Adaptation of Dentures Printed at 0 Versus 45 Degrees
NCT06164366 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Bone-Implant Contact Surface Influence on Dental Implant Stability
NCT06178796 ·Status: COMPLETED ·Phase: NA
-
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812 ·Status: RECRUITING ·Phase: NA
-
Using Digital Technology Versus Conventional Relining Procedure for Correction of Loose Maxillary Complete Denture
NCT06366321 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Tooth Modified Scan Bodies as a Novel Technique
NCT06177782 ·Status: COMPLETED ·Phase: NA
-
Digital Versus Conventional Altered Cast Techniques For Constructing Mandibular Distal Extension Removable Partial Dentures Using Digitally Fabricated Frameworks: Alveolar Bone Height Changes
NCT05899712 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Digital Implant Impression
NCT04627649 ·Status: UNKNOWN
-
Denture Retention of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients
NCT07290322 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Digital Evaluation of Accuracy for Removable Partial Denture Frameworks
NCT06412159 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Three Hard Relining Materials in Complete Dentures
NCT02203279 ·Status: COMPLETED ·Phase: NA
-
Assessment of the Accuracy of Surgical Guide Designed From Dental Model Optical Scan Versus Impression Inversion With Markers Techniques in Computer Guided Implantology. Randomized Clinical Trial.
NCT03367949 ·Status: UNKNOWN ·Phase: NA