Bone Changes Assessment in Screw-Retained Maxillary Complete Denture With Electric Welded Framework Versus Cast One

NCT04548258 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 12

Last updated 2020-10-06

No results posted yet for this study

Summary

comparing bony changes around implants that will be joined by ametal framework either with electric weiling or with the conventional casting metal

Conditions

  • Bone Resorption

Interventions

DEVICE

electric intraoral weilding

weilding metal framework to the implants in completely edentulous maxilla using electric weilding device intraorally

DEVICE

casting

casting metal framework

Sponsors & Collaborators

  • Cairo University

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
45 Years
Max Age
65 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2020-10-31
Primary Completion
2021-10-31
Completion
2021-11-30

Countries

  • Egypt

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.