Using Electrical Bioimpedance Assessments to Estimate Perioperative Total Body Water and Postoperative Fluid Need
NCT02200055 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 86
Last updated 2018-08-28
Summary
Being able to accurately monitor patient bodily fluid levels during and after surgery is very important, as there are a number of complications that can arise if a patient's fluid levels become unbalanced, such as swelling within or pressure on various bodily organ systems. There are several different ways that physicians can monitor a patient's fluid balance during and after surgery, such as measuring the amount of urine output or the use of central venous catheters which measure the pressure in the veins entering the heart. Most of these techniques are invasive since they require tubes to be inserted into the body. A potential alternative would be to use a noninvasive technique such as electrical bioimpedance (BIA).
Bioimpedance assessments work by using small electrical currents that can accurately predict both the water surrounding the outside of cells in the body, as well as the total amount of water in the entire body. Electrical bioimpedance assessments have been used to estimate patient swelling following surgery (edema), to measure the volume of blood the heart is pumping out, as well as to calculate body fat percentages.
The goal of this study is to relate this technology to fluid shifts within the body that occur as a result of surgery, in particular, major intra-abdominal surgeries. By using bioimpedance during and after surgery, the investigators will compare the data collected with that calculated by using traditional measures of body fluid status, such as urine output and intraoperative blood loss. During the study, the bioimpedance monitors will not replace the standard bodily fluid monitors and will not interfere with their readings. Additionally, the electrical current produced by the bioimpedance monitors is too small for patients to feel and will not interfere with medical devices such as pacemakers.
Conditions
- Intestinal Cancer
- Diverticulitis
- Pancreatic Cancer
- Gastroesophageal Reflux Disease
Interventions
- DEVICE
-
Bodystat Quadscan 4000
Each patient involved in the study will be evaluated with a bioimpedance monitor to assess total body water, estimated body water, and intravascular body water volume preoperatively, postoperatively, and daily during the postoperative recovery period. Bioimpedance Assessment
Sponsors & Collaborators
-
United States Naval Medical Center, Portsmouth
lead FED
Principal Investigators
-
Christopher Oxner, MD · United States Naval Medical Center, Portsmouth
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-05-31
- Primary Completion
- 2015-07-31
- Completion
- 2015-07-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Effects of PEEP on Heart and Lungs in Obese Subjects
NCT02523352 ·Status: UNKNOWN ·Phase: NA
-
Thoracic Fluid Assessment by Contrast-enhanced Magnetic Resonance Imaging and Bioimpedance
NCT02364193 ·Status: COMPLETED ·Phase: NA
-
Extracellular Water in Covid 19 Pneumonia
NCT04416009 ·Status: UNKNOWN
-
Body Composition Monitoring for Determination of the Fluid Status in Volunteers Undergoing Intravenous Fluid Therapy
NCT02296294 ·Status: COMPLETED ·Phase: NA
-
Using Electrical Impedance Tomography to Investigate the Relationship Between Airflow Rate During High-flow Oxygen Therapy and Pressure in Patients With Heart Failure Compared to Non-invasive Ventilation
NCT06107907 ·Status: RECRUITING ·Phase: NA
-
Positional Effects on Lung Ventilation and Perfusion in Obesity
NCT07341113 ·Status: COMPLETED
-
Muscle and Subcutaneous Tissue Variation by Ultrasound and Impedance Linked to Fluid Balance in ICU Patients
NCT06697470 ·Status: RECRUITING
-
A Study of Body Fat Distribution and Airway Mechanics in Healthy Adults
NCT07019831 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Electrical Impedance Tomography for Quantification of Pulmonary Edema in Acute Respiratory Distress Syndrome Patients
NCT02870894 ·Status: UNKNOWN
-
Change In Diaphragmatic Thickness Predicts Extubation Success
NCT02656199 ·Status: TERMINATED
-
Combining Electrical Impedance Tomography and Thoracic Ultrasound Toinvestigate Dynamic Changes
NCT06958770 ·Status: NOT_YET_RECRUITING
-
Contributing Factors to Local Bioimpedance Spectroscopy
NCT06003205 ·Status: COMPLETED ·Phase: NA
-
Influence of Fluid Challenge on End-Expiratory Lung Impedance in Mechanically Ventilated Patients Monitored With Electrical Impedance Tomography
NCT02992002 ·Status: COMPLETED
-
Machine Learning and 3D Image-Based Modeling for Real-Time Body Weight and Body Composition Estimation During Emergency Medical Care. Study 3
NCT06645548 ·Status: WITHDRAWN ·Phase: NA
-
Bioimpedance Analysis in Septic Intensive Care Unit (ICU) Patients
NCT01379404 ·Status: COMPLETED
-
Evaluation of the Diaphragm Performance During Weaning From Mechanical Ventilation
NCT06203353 ·Status: RECRUITING
-
Influence of Different PEEP Levels and Tidal Volumes on Regional Lung Function
NCT03326414 ·Status: UNKNOWN ·Phase: NA
-
Adiposity Distribution in Acute Respiratory Failure
NCT07019987 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Capnography in the Post-Anesthesia Care Unit (PACU)
NCT03076047 ·Status: UNKNOWN
-
EIT During FCV in the Intensive Care Unit
NCT05644418 ·Status: COMPLETED ·Phase: NA
-
Machine Learning and 3D Image-Based Modeling for Real-Time Body Weight and Body Composition Estimation During Emergency Medical Care: Study 2
NCT06646133 ·Status: WITHDRAWN
-
Thoracic Fluid Content by Electrical Cardiometry Versus Lung Ultrasound in Mechanically Ventilated Patients
NCT05272982 ·Status: COMPLETED
-
A 3D Tablet Sensor Approach to the Measurement of a Lymphedema
NCT04821440 ·Status: COMPLETED ·Phase: NA
-
Using Ultrasound to Study Respiratory Muscle Function in Critically Ill Patients
NCT03139695 ·Status: COMPLETED
-
Blood Loss Measurement Using Electrical Impedance Tomography
NCT05287334 ·Status: UNKNOWN ·Phase: NA