EIT During FCV in the Intensive Care Unit
NCT05644418 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10
Last updated 2024-01-12
Summary
The goal of this clinical trial is to study the effects of Flow Controlled Ventilation (FCV) following conventional mechanical ventilation (Pressure or Volume Controlled Ventilation) in postcardiac surgery ICU-patients to allow for future power calculations and to obtain experience with FCV.
The main questions it aims to answer are:
* What is the effect of FCV on the lung volume measured by Electrical Impedance Tomography (EIT)?
* What is the effect of FCV on the minute volume?
* What is the effect of FCV on the mechanical power and dissipated energy?
Participants will be ventilated with PCV at baseline and then switched to FCV for 90 minutes while the lung volume, minute volume and mechanical power and dissipated energy levels are measured.
Conditions
- Post-cardiac Surgery
Interventions
- DEVICE
-
Flow Controlled Ventilation (FCV)
FCV is started with the same settings as PCV (PEEP, Ppeak, FiO2) and after 30 minutes FCV is optimized concerning the driving pressure and PEEP using the dynamic compliance. After a total of 60 minutes the flow is adjusted based on the arterial blood gas.
Sponsors & Collaborators
-
Ventinova
collaborator UNKNOWN - lead OTHER
Principal Investigators
-
Henrik Endeman, MD, PhD · Erasmus MC, Rotterdam
Study Design
- Allocation
- NA
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- SEQUENTIAL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-02-22
- Primary Completion
- 2023-05-09
- Completion
- 2023-05-09
Countries
- Netherlands
Study Locations
More Related Trials
-
Electrical Impedance Tomography for Optimization of Positive End-Expiratory Pressure: Acute Respiratory Distress Syndrome
NCT03793842 ·Status: COMPLETED ·Phase: NA
-
Automated Analysis of EIT Data for PEEP Setting
NCT03653806 ·Status: COMPLETED
-
Electric Impedance Tomography Before and After Dilatative Tracheotomy
NCT02161328 ·Status: COMPLETED
-
Quality of Perioperative Invasive Ventilation in PICU
NCT03455413 ·Status: COMPLETED
-
The Clinical Application of EIT in Clinically Ill Patients: a Cross-sectional Study
NCT06954415 ·Status: NOT_YET_RECRUITING
-
Clinical Application of Electrical Impedance Tomography for Individual Adjustment of Ventilator Settings
NCT02703012 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Postoperative Ventilation Distribution With Electrical Impedance Tomography
NCT05389735 ·Status: UNKNOWN
-
Electrical Impedance Tomography Guided Assessment of Optimum PEEP Levels During Mechanical Ventilation in Lateral Decubitus Position
NCT03704038 ·Status: COMPLETED ·Phase: NA
-
Influence of Fluid Challenge on End-Expiratory Lung Impedance in Mechanically Ventilated Patients Monitored With Electrical Impedance Tomography
NCT02992002 ·Status: COMPLETED
-
Eit in ArdS for Tcav Setting (EAST Study)
NCT06408272 ·Status: NOT_YET_RECRUITING
-
EIT Assessment of Overdistension in ARDS Patients in Prone Position
NCT06536543 ·Status: RECRUITING
-
Ventilator-induced Right Ventricular Injury During EIT-based PEEP Titration in Patients With ARDS
NCT05583461 ·Status: COMPLETED ·Phase: NA
-
Non-Invasive Measurements of Changes in Pulmonary Artery Pressure in Intensive Care Unit Patients Using Electrical Impedance Tomography - A Feasibility Study
NCT06544148 ·Status: RECRUITING
-
Monitoring of Regional Lung Ventilation by Chest Electrical Impedance in the Course of Extubation
NCT04180410 ·Status: UNKNOWN ·Phase: NA
-
Effect of Different VV ECMO Flows on Lung Perfusion Monitored by EIT
NCT05778292 ·Status: UNKNOWN
-
Monitorings the Physiological Mechanism of Airway Pressure Release Ventilation in ARDS Patients by EIT
NCT05406427 ·Status: UNKNOWN
-
Ultra-protective Ventilation Monitored by Electrical Impedance Tomography in Patients With Severe Acute Respiratory Distress Syndrome on Veno-venous ECMO
NCT05717218 ·Status: RECRUITING ·Phase: NA
-
Electrical Impedance Tomography in One-Lung Ventilation
NCT03728010 ·Status: UNKNOWN
-
Electrical Impedance Tomography (EIT) and Physiotherapy
NCT01932567 ·Status: UNKNOWN ·Phase: NA
-
Association Between EIT and CT During PEEP Titration in Patients With Acute Respiratory Failure
NCT07175194 ·Status: RECRUITING
-
Electrical Impedance Tomography (EIT) Monitoring in Adults With ALI or ARDS
NCT01272882 ·Status: COMPLETED ·Phase: NA
-
Using Electrical Impedance Tomography to Investigate the Relationship Between Airflow Rate During High-flow Oxygen Therapy and Pressure in Patients With Heart Failure Compared to Non-invasive Ventilation
NCT06107907 ·Status: RECRUITING ·Phase: NA
-
Combining Electrical Impedance Tomography and Thoracic Ultrasound Toinvestigate Dynamic Changes
NCT06958770 ·Status: NOT_YET_RECRUITING
-
Pressure Opening With Electrical Impedance Tomography
NCT05825534 ·Status: UNKNOWN ·Phase: NA
-
Monitoring of Lung Ventilation Through Electrical Impedance Tomography During Pediatric Surgery
NCT06370507 ·Status: NOT_YET_RECRUITING