Optimal Laryngoscopic View to Enable GlideScope-assisted Tracheal Intubation
NCT02144207 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 160
Last updated 2017-01-31
Summary
Some surgical procedures require general anesthesia (i.e., the patient is 'asleep'). When under general anesthesia, these patients' airways must be managed to ensure continuous flow of oxygen to the lungs, and in most cases, delivery of anesthetic gases to the lungs. Most often for airway management under general anesthesia, a plastic breathing tube is placed though the voicebox ("larynx") into the windpipe ("trachea"), a process known as "tracheal intubation". To safely intubate, the larynx must first be exposed. In many cases, this is achieved by using a device known as a direct laryngoscope, which is like a curved, lighted tongue depressor. It is used to gently move the tongue out of the way, to expose the larynx. When the larynx is easily seen, passing the breathing tube is usually also easy. Unfortunately, in 2-5% of cases, it is difficult or impossible to view the larynx using the direct laryngoscope. This then creates difficulty with tube passage. A number of options exist to deal with this situation, including, within the last 10 years, a class of device called "video laryngoscopes". These devices use a small video chip located towards the end of the blade, which, by providing transmission of an image of the larynx 'around the corner' to a screen outside the patient, enable a view to be obtained (when no such view could be obtained with direct laryngoscope). With the larynx now indirectly visualized, tube passage can proceed. However, it's not that easy. When using these 'around the corner' videolaryngoscopes, tube passage can be more difficult, as the tube must be guided around a 90 degree bend from the mouth to the trachea, which sits at right angles to the mouth. Less difficulty occurs with tube passage when the direct laryngoscope is used because the blade compresses the tongue out of the way, creating a straight line from teeth to the larynx and windpipe beyond.
The GlideScope is one example of video laryngoscope, and has been in use here at CDHA for 10 years. It has been extensively studied over the ten years, with more than 300 studies appearing in the literature. The investigators know from these studies that it is very effective at delivering a view of the larynx when direct laryngoscopy has failed to do so. However, getting the tube to and through the larynx into the trachea, even with a good view, can be problematic. Furthermore, it is the impression of some clinicians that when a close-up, full view of the larynx is obtained (as is optimal for direct laryngoscopy) with the GlideScope, tube passage appears to be a little more difficult than seems to be the case when only a partial view of the larynx is obtained, from a little further away. The investigators don't know why this may be so, but may relate to one or more of a number of reasons, including (when too close) angling the larynx into an unfavorable angle, or (when further away) more favorably reducing the angle between mouth and larynx and trachea. However, no guidance on this question appears in the peer-reviewed medical literature, and no studies have been done. There is some suggestion in non peer-reviewed internet sites on airway management that a partial view may be better, but again, this has not been scientifically studied or validated one way or another.
As mentioned, the GlideScope has been in regular use in CDHA for many years. Most often, it is used when difficulty with tracheal intubation is anticipated or has already been encountered in the anesthetized patient, although some airway experts suggest that within the near future, all intubations will occur with some sort of video laryngoscope.
It is important to research the present question as in contemporary practice many anesthesiologists, faced with a patient in whom they are anticipating difficult direct laryngoscopy proceed with putting the patient to sleep, relying on the video laryngoscope to enable them to intubate. With a patient now anesthetized and not breathing, if they then have trouble intubating the patient in spite of getting a view of the larynx, harm could occur to the patient from a failed intubation situation. Furthermore, there are now a number of studies documenting that patient morbidity can increase with multiple intubation attempts.
Conditions
- Time it Takes to Successfully Intubate the Patient With the GlideScope
- Time to Intubate Between the Two Views
Interventions
- DEVICE
-
Glidescope
Sponsors & Collaborators
-
Nova Scotia Health Authority
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2014-09-30
- Primary Completion
- 2015-06-30
- Completion
- 2015-12-31
Countries
- Canada
Study Locations
More Related Trials
-
Glottic Visualization & Ease of Intubation With Different Laryngoscope Blades
NCT01352299 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Glidescope and Macintosh Laryngoscope for Double Lumen Endotracheal Tube Intubation
NCT01404780 ·Status: COMPLETED ·Phase: NA
-
Effectiveness and Safety of the Levitan Scope for Laryngoscopy and Tracheal Intubation With a Simulated Difficult Airway
NCT01491984 ·Status: COMPLETED ·Phase: PHASE4
-
Videolaryngoscopes for Double Lumen Tube Intubations
NCT02305667 ·Status: COMPLETED ·Phase: NA
-
Comparison of GlideScope Specific Stylet to Malleable Stylet for GlideScope Intubation
NCT00434720 ·Status: COMPLETED ·Phase: NA
-
Measurement of Forces Applied Using a Macintosh Direct Laryngoscope Compared to GlideScope Video Laryngoscope
NCT01814176 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Macintosh, King Vision®, Glidescope® and AirTraq® Laryngoscopes in Routine Airway Management
NCT01914523 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
GlideScope Video Laryngoscope Versus Fiberoptic Intubation
NCT01091948 ·Status: COMPLETED ·Phase: NA
-
Tracheal Intubation of Morbidly Obese Patients. GlideScope Versus Direct Laryngoscopy
NCT00917033 ·Status: COMPLETED ·Phase: PHASE4
-
GlideScope Groove vs. Standard GlideScope: A Non-inferiority Study
NCT01489605 ·Status: WITHDRAWN ·Phase: NA
-
Application of Visual Laryngeal Mask Airway Combined With Endotracheal Intubation in General Anesthesia
NCT04719767 ·Status: UNKNOWN ·Phase: NA
-
Comparison of GlideScope-Specific Rigid Stylet to Standard Malleable Stylet for GlideScope Intubation by Novice Operators
NCT00884754 ·Status: COMPLETED ·Phase: NA
-
GlideScope Groove Versus Macintosh Blade for Double-Lumen Endotracheal Tube Intubation
NCT01488695 ·Status: WITHDRAWN ·Phase: NA
-
Intubation of a Pediatric Manikin in Difficult Airway by Novice Personnel: A Comparison of Glidescope and Airtraq
NCT02290249 ·Status: COMPLETED ·Phase: PHASE4
-
Learning and Performance of Glidescope® Videolaryngoscope Intubation
NCT01790646 ·Status: UNKNOWN
-
Incidence of Sore Throat With Traditional Intubation Blades or Glidescope Blade
NCT02033564 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Two GlideScope Intubation Techniques
NCT01865643 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Video Laryngoscopy in Patients With Head and Neck Pathology
NCT03265938 ·Status: COMPLETED
-
Videolaryngoscope Versus Fiberoptic Bronchoscope for the Awake Intubation
NCT02169232 ·Status: UNKNOWN ·Phase: NA
-
Indirect Laryngoscopy for Nasal Intubation
NCT00910156 ·Status: COMPLETED ·Phase: PHASE4
-
Laryngoscope Prototype Tested Against the Traditional Macintosh Blade
NCT00378170 ·Status: UNKNOWN ·Phase: NA
-
Comparison Study in Adult Surgical Patients of 5 Airway Devices
NCT00602979 ·Status: COMPLETED ·Phase: NA
-
Awake Endotracheal Intubation in Cervical Injury
NCT05619965 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Lighted Stylet and GlideScope for Double-lumen Endobronchial Intubation
NCT03514745 ·Status: UNKNOWN ·Phase: NA
-
GlideScope®Video Laryngoscope for Difficult Intubation: Implication of the Size of Blade
NCT01616771 ·Status: COMPLETED ·Phase: NA