Comparison of GlideScope Specific Stylet to Malleable Stylet for GlideScope Intubation
NCT00434720 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 70
Last updated 2008-10-16
Summary
The GlideScope video laryngoscope (Verathon) is an intubating device that uses a high-resolution camera embedded into a plastic laryngoscope blade. An LED provides illumination. The GlideScope often provides a good laryngoscopic view, but passing the endotracheal tube (ETT) through the vocal cords is sometimes difficult. Because of the 60 degree anterior curvature of the GlideScope's blade, ETT's must have stylets inserted so that the ETT distal tip can be positioned anteriorly. Various authors have recommended different angles of the ETT to optimally place it into the trachea. Previous study demonstrated that 90 degree sharp bend was both faster and subjectively easier in a heterogeneous group of intubators. With the introduction of a rigid GlideScope Specific Stylet by the manufacturer, the question arises as to the the best configuration of stylet for the ETT. Therefore, this prospective, randomized, single-blinded trial is proposed.
The null hypothesis is that there will be no difference between the GlideScope Specific Stylet and the standard malleable stylet.
Conditions
- Intubation, Endotracheal
Interventions
- DEVICE
-
GlideScope Specific Stylet
Sponsors & Collaborators
-
London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
lead OTHER
Principal Investigators
-
Timothy P Turkstra, M. Eng, MD · University of Western Ontario, London Health Sciences Center
Study Design
- Allocation
- RANDOMIZED
- Purpose
- HEALTH_SERVICES_RESEARCH
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2007-01-31
- Primary Completion
- 2007-05-31
- Completion
- 2007-05-31
Countries
- Canada
Study Locations
More Related Trials
-
GlideScope Groove vs. Standard GlideScope: A Non-inferiority Study
NCT01489605 ·Status: WITHDRAWN ·Phase: NA
-
Comparison of Early Endotracheal Tube Insertion With GlideScope Use
NCT01564082 ·Status: COMPLETED ·Phase: NA
-
Comparison of Lighted Stylet and GlideScope for Double-lumen Endobronchial Intubation
NCT03514745 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Conventional GlideScope to Single-Use GlideScope Cobalt for Orotracheal Intubation
NCT00459797 ·Status: COMPLETED ·Phase: NA
-
Measurement of Forces Applied Using a Macintosh Direct Laryngoscope Compared to GlideScope Video Laryngoscope
NCT01814176 ·Status: COMPLETED ·Phase: NA
-
Comparison of Simultaneous Endotracheal Tube Insertion With GlideScope Use
NCT02787629 ·Status: COMPLETED ·Phase: NA
-
Optimal Laryngoscopic View to Enable GlideScope-assisted Tracheal Intubation
NCT02144207 ·Status: COMPLETED ·Phase: NA
-
The Videolaryngoscopy Versus Direct Laringoscopy for Residents Intubation Study
NCT06842082 ·Status: COMPLETED ·Phase: NA
-
Learning and Performance of Glidescope® Videolaryngoscope Intubation
NCT01790646 ·Status: UNKNOWN
-
Safety and Efficacy of Endotracheal Intubation Using Glidescope Video-Laryngoscope
NCT01683526 ·Status: COMPLETED ·Phase: NA
-
Comparison of Intubation Conditions Between the Gliderite and the S-Guide
NCT02519647 ·Status: COMPLETED ·Phase: NA
-
McGrath Mac Videolaryngoscope Versus Macintosh Laryngoscope for Orotracheal Intubation in Critical Care Unit
NCT02413723 ·Status: COMPLETED ·Phase: NA
-
Intubation Success Rate_Rigid Video Stylet Vs Video Laryngoscope
NCT02769221 ·Status: UNKNOWN ·Phase: NA
-
Comparative Evaluation of the McGrath Videolaryngoscope and the Direct Laryngoscopy for Tracheal Intubation in the Prehospital Setting
NCT04930419 ·Status: UNKNOWN ·Phase: PHASE3
-
Use of a Low-cost Video Laryngoscope on Manikin
NCT06176677 ·Status: COMPLETED
-
Prehospital Tracheal Intubation Technique Using Initial Direct Laryngoscopy During Videolaryngoscopy
NCT06918717 ·Status: COMPLETED ·Phase: NA
-
Videolaryngoscope Versus Fiberoptic Bronchoscope for the Awake Intubation
NCT02169232 ·Status: UNKNOWN ·Phase: NA
-
GlideScope Groove Versus Macintosh Blade for Double-Lumen Endotracheal Tube Intubation
NCT01488695 ·Status: WITHDRAWN ·Phase: NA
-
A Comparison Between Two Video Laryngoscopes,in Successfully Intubating Pediatric Mannequins w/wo Difficult Airways
NCT02198742 ·Status: COMPLETED ·Phase: PHASE1
-
Comparison of the Macintosh, King Vision®, Glidescope® and AirTraq® Laryngoscopes in Routine Airway Management
NCT01914523 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Comparison of the Glidescope and Macintosh Laryngoscope for Double Lumen Endotracheal Tube Intubation
NCT01404780 ·Status: COMPLETED ·Phase: NA
-
The Comparison of the Success Rate of the Endotracheal Intubation Between the Stylet and the Frova With Acute Angled Videolaryngoscope
NCT03962374 ·Status: UNKNOWN ·Phase: NA
-
Videolaryngoscope vs Classic Laryngoscope in Teaching Neonatal Endotracheal Intubation: a Randomized Controlled Trial.
NCT01394783 ·Status: COMPLETED ·Phase: PHASE4
-
GlideScope®Video Laryngoscope for Difficult Intubation: Implication of the Size of Blade
NCT01616771 ·Status: COMPLETED ·Phase: NA
-
Glossopharyngeal Nerve Blockade for Awake Videolaryngoscope Assisted Endotracheal Intubation in the Morbidly Obese
NCT01791439 ·Status: UNKNOWN ·Phase: NA