Affixing Polypropylene Mesh Using Barbed Suture (Quill™ SRS) During Robotic Assisted Laparoscopic Sacrocolpopexy

NCT01608568 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 32

Last updated 2012-06-01

No results posted yet for this study

Summary

1.0 STUDY OBJECTIVE 1.1 PRIMARY OBJECTIVE - To compare two methods of polypropylene mesh attachment during robotic assisted laparoscopic sacrocolpopexy (RALSC): running technique using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).

1.2 SECONDARY OBJECTIVE - To compare robotic assisted laparoscopic sacrocolpopexy anatomic failure rates at 6 months post-operative follow-up using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA). The investigators will also assess mesh erosion rates, costs, and surgeon satisfaction rates.

2.0 HYPOTHESIS 2.1 Primary: 2.1.a. Attachment of mesh using the running technique with self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) will be faster than the standard fixation interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).

2.2 Secondary: 2.2.a. Attachment of mesh using the running technique with self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) will be less costly than the standard fixation interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).

2.2.b. Failure rates and mesh erosion rates for each technique will be equally low.

2.2.c. Surgeons will prefer the barbed running technique over the interrupted technique based on subjective surgeon satisfaction questionnaires.

Conditions

  • Prolapse

Interventions

DEVICE

Device is the type of suture used: Quill suture vs. Interrupted suture

To compare two methods of polypropylene mesh attachment during robotic assisted laparoscopic sacrocolpopexy (RALSC): running technique using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).

Sponsors & Collaborators

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
FEMALE
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2010-11-30
Primary Completion
2012-08-31
Completion
2013-08-31

Countries

  • United States

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.