Affixing Polypropylene Mesh Using Barbed Suture (Quill™ Srs) During Laparoscopic Sacrocolpopexy Randomized Controlled Trial (Quill Lsc)
NCT01551992 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 32
Last updated 2014-09-16
Summary
1.0 STUDY OBJECTIVE 1.1 PRIMARY OBJECTIVE - To compare two methods of polypropylene mesh attachment during laparoscopic sacrocolpopexy (LSC): running technique using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).
1.2 SECONDARY OBJECTIVE - To compare laparoscopic sacrocolpopexy anatomic failure rates at 6 months post-operative follow-up using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA). The investigators will also assess mesh erosion rates, costs, and surgeon satisfaction rates.
2.0 HYPOTHESIS 2.1 Primary: 2.1.a. Attachment of mesh using the running technique with self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) will be faster than the standard fixation interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).
2.2 Secondary: 2.2.a. Attachment of mesh using the running technique with self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) will be less costly than the standard fixation interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).
2.2.b. Failure rates and mesh erosion rates for each technique will be equally low.
2.2.c. Surgeons will prefer the barbed running technique over the interrupted technique based on subjective surgeon satisfaction questionnaires.
Conditions
- Prolapse
Interventions
- PROCEDURE
-
Quill suture vs. Interrupted suture
To compare two methods of polypropylene mesh attachment during laparoscopic sacrocolpopexy (LSC): running technique using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).
Sponsors & Collaborators
-
Kaiser Permanente
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- FEMALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2010-11-30
- Primary Completion
- 2014-07-31
- Completion
- 2014-07-31
Countries
- United States
Study Locations
More Related Trials
-
Comparison of Sacrospinous Ligament Fixation and Uterosacral Ligament Suspension for Apical Prolapse Surgery: A Randomized Clinical Trial
NCT05668130 ·Status: UNKNOWN ·Phase: NA
-
SurgiWrapTM to Reduce Soft Tissue Attachment & Incidence Early Post-Operative Bowel Obstruction in Colorectal Surgery
NCT00531739 ·Status: COMPLETED ·Phase: PHASE4
-
Continuous Locked Non-barbed Suture for Mesh Fixation During Laparoscopic Sacral Colpopexy for Severe Pelvic Organ Prolapse
NCT03427606 ·Status: UNKNOWN ·Phase: NA
-
Outcomes of Anterior Colporrhaphy Versus Graft Reinforced Anterior Prolapse Repair
NCT00535301 ·Status: COMPLETED ·Phase: PHASE4
-
Different Types of Suture for Sacral Colpopexy
NCT03582410 ·Status: COMPLETED ·Phase: NA
-
Permanent Versus Absorbable Colpopexy Trial
NCT02277925 ·Status: COMPLETED ·Phase: NA
-
INSORB Versus Subcuticular Sutures at Cesarean Section
NCT01687972 ·Status: TERMINATED ·Phase: PHASE1
-
Sutures Versus Glue in Laparoscopic Port Site Closure.
NCT03843866 ·Status: UNKNOWN ·Phase: NA
-
A Randomized Controlled Trial of Permanent vs Absorbable Suture for Uterosacral Ligament Suspension
NCT02888093 ·Status: COMPLETED ·Phase: NA
-
Barbed Suture Versus Non-Barbed Suture for Posterior Colporrhaphy
NCT04658784 ·Status: COMPLETED ·Phase: NA
-
Composite Outcomes of Mesh vs Suture Techniques for Prolapse Repair: A Randomized Controlled Multicentre Trial
NCT02965313 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Barbed-suture Efficiency Study for Sacrocolpopexy
NCT05760794 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Study to Compare Suture Material in Closure of Uterine Incision in Cesarian Section
NCT02517710 ·Status: COMPLETED ·Phase: NA
-
Trial Comparing Barbed and Non-barbed Suture for Uterine Incision Closure at Cesarean Section
NCT02962011 ·Status: COMPLETED ·Phase: PHASE3
-
Closing Uterine Incision During C-section Using Barbed Suture (Stratafix) or Vicryl Suture.
NCT03159871 ·Status: COMPLETED ·Phase: NA
-
Anchorsure Versus Capio for Sacrospinous Ligament Fixation
NCT03565640 ·Status: COMPLETED ·Phase: NA
-
Use of 2-octylcyanoacrylate (Dermabond) Versus 5-0 Fast Absorbing Gut During Cutaneous Wound Closure
NCT02547077 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Bioresorbable Sheet to Prevent Intra-Abdominal Adhesions in Colorectal Surgeries
NCT00902148 ·Status: COMPLETED ·Phase: PHASE4
-
Intrauterine Stent Placement Following Hysteroscopic Septum Resection
NCT07032506 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Absorbable Staples Versus Conventional Skin Closure in Women Undergoing Cesarean Delivery
NCT07167199 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
PMCF-study Using Novosyn® Quick Suture Material for Skin Closure
NCT02680886 ·Status: COMPLETED
-
Suture Versus Glue (Dermabond) Closure During Cesarean Delivery
NCT02831946 ·Status: UNKNOWN ·Phase: PHASE4
-
Patient Reported Experiences and Outcomes Associated with Standard C-Section Wound Closure Versus STRATAFIX/DERMABOND PRINEO Wound Closure (CS-PREO)
NCT06614829 ·Status: RECRUITING ·Phase: NA
-
Efficacy of IFABONDTM Synthetic Glue for Fixation of Implanted Material in Laparoscopic Sacrocolpopexy: a Prospective Multicenter Study
NCT02011373 ·Status: COMPLETED ·Phase: NA
-
ZipLine Incision Approximation Verses Suture:ZIPS3 Physician Preference Study
NCT03201536 ·Status: WITHDRAWN ·Phase: NA