Evaluation of Composite Veneers Fabricated by 3D Printing and Milling Technologies
NCT07756333 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 14
Last updated 2026-08-12
Summary
The clinical study aimed to evaluate the clinical performance, color stability, and wear of indirect composite veneers produced using 3D printing and milling technologies.
Conditions
- Dental Restoration, Permanent
- Dental Restoration Wear
Interventions
- OTHER
-
Group I (n=28): were restored with VarseoSmile TriniQ, Bego
A total of fifty-six anterior indirect veneers will be fabricated using 3D printing and milling technologies. The veneers will be divided into two groups according to the technique of fabrication. Group I: 28 veneers will be done using 3D printing technology (VarseoSmile TriniQ, Bego), and group II: 28 veneers will be done using milling technology (Cerasmart 270, GC). Veneer restorations will be fabricated checked, and cemented, then will be evaluated using the modified FDI criteria at baseline, three months, six months, and one year. Moreover, color stability and surface wear of the restorations will be evaluated in each follow-up session.
- OTHER
-
Group II (n=28): were restored with Cerasmart 270, GC
A total of fifty-six anterior indirect veneers will be fabricated using 3D printing and milling technologies. The veneers will be divided into two groups according to the technique of fabrication. Group I: 28 veneers will be done using 3D printing technology (VarseoSmile TriniQ, Bego), and group II: 28 veneers will be done using milling technology (Cerasmart 270, GC). Veneer restorations will be fabricated checked, and cemented, then will be evaluated using the modified FDI criteria at baseline, three months, six months, and one year. Moreover, color stability and surface wear of the restorations will be evaluated in each follow-up session.
Sponsors & Collaborators
-
youssef alaa
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 45 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-05-01
- Primary Completion
- 2026-08-05
- Completion
- 2026-08-05
Countries
- Egypt
Study Locations
More Related Trials
-
Clinical Evaluation of Bioactive Resin Composites Versus Caries Control Technique in Management of Class I Carious Cavities in High Caries Risk Patients: a Randomized Clinical Trial
NCT06797843 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Evaluation of Prefabricated Versus 3D-Printed Composite Resin Veneers: in Vivo Study
NCT07691658 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Clinical Evaluation of 3D-Printed Versus Semi-Direct Composite Resin Restorations
NCT07676929 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
3-D Printed Resin Composite Versus Milled Resin Composite and Hybrid Ceramic Onlays: 2-Year Clinical Performance, Microtensile Bond Strength, Marginal and Internal Adaptation
NCT07633717 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Effect of Different Types of Resin Cements on the Color Stability of Two Different Types of Ceramic Veneers
NCT06368869 ·Status: COMPLETED ·Phase: NA
-
Effect of Different Cavity Designs on the Clinical Performance of 3D- Printed Resin Composite Partial-Coverage Restorations in Vital Molars
NCT07667946 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Performance and Fit of 3D-Printed Versus Milled Endocrowns: An 18-Month Trial
NCT07708077 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Custom-Made Zirconia Crowns and 3D-Printed Resin Crowns Versus Ready-Made Zirconia Crowns in Primary Molars
NCT06581510 ·Status: RECRUITING ·Phase: NA
-
Clinical Assessment of Indirect Restoration Fabricated From Nano Hybrid Composite Blocks Versus Ceramic Blocks in Badly Broken Teeth One Year Follow up
NCT04563624 ·Status: UNKNOWN ·Phase: PHASE1
-
Direct Resin Composite Restoration of Primary Anterior Teeth Using Custom 3D Printed Templates
NCT06478004 ·Status: COMPLETED ·Phase: NA
-
Two-Year Clinical Performance of Self-Cured Resin Composite in Comparison to Light-Cured Bioactive Resin Composite in Restoring Occlusal Cavities of Posterior Teeth.
NCT07480070 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Using Self-adhering Flowable Resin Composite in Repairing Old Defective Resin Composite Restorations Over 18 Months Follow up. (A Randomized Clinical Trial)
NCT06260644 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Aesthetic Performance of Two Injectable Resin Composites in Class V Cavities: A Randomized Clinical Trial
NCT06950762 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Bioactive Giomer Material Versus Nanohybrid Resin Composite in Deep Marginal Elevation
NCT06497231 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical and Radiographic Evaluation of Indirect Pulp Capping Using Platelet Rich Fibrin Versus Mineral Trioxide Aggregate in Deep Carious Molars: a Randomized Controlled Trial
NCT06889363 ·Status: NOT_YET_RECRUITING ·Phase: PHASE2
-
Resin Modified Glass Ionomer Versus Self-Adhesive Resin Composite Restorative Systems
NCT06543680 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Bioflex and Zirconia Crowns Versus Stainless Steel Crowns on Primary Molars: Randomized Controlled Clinical Trial
NCT07156838 ·Status: COMPLETED ·Phase: NA
-
Esthetic Outcome of 3D Printed Hybrid Ceramics as Final Restorations for Single Screw Retained Implant.
NCT07154602 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Evaluation of Indirect Tooth-Colored Onlays With Cervical Margin Relocation
NCT07157410 ·Status: RECRUITING ·Phase: NA
-
Clinical Performance of Two Different Resin-Matrix Ceramic Restorations
NCT07265609 ·Status: COMPLETED ·Phase: NA
-
This Study is Conducted to Evaluate the Clinical Performance of Indirect Overlay Restorations With Different Cavity Preparation Designs in Endodontically Treated Molars.
NCT07614451 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Evaluation of 3D Printed Versus CAD/CAM Milled Onlays
NCT06774560 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Evaluation of Wear Resistance and Bioactivity of Self Cured Bioactive Resin Composite
NCT07262086 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Clinical Evaluation of Bioactive Restorative vs. RMGI in Class V: A Randomized Control Trial
NCT03771196 ·Status: UNKNOWN ·Phase: NA
-
Wear Measurement of Opposing Enamel to Milled Resin Matrix Ceramic Versus Bulk Fill Resin Composite After 2 Years
NCT06807125 ·Status: COMPLETED ·Phase: NA