Assessment Polyether Ether Ketone (PEEK) Custom Made Plates Versuscustom Made Titanium Plates in Treatment of Mandibular Body Fractures
NCT07729345 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2026-07-27
Summary
The design of the custom made Plates is customized to meet the individual needs of each patient and surgeon. By selecting plate design features, surgeons can customize the plate to create a patient specific solution. The Patient Specific Plates are manufactured to the planned patient anatomy, eliminating the time needed for intraoperative adaption and creating a stronger plate with a lower overall profile.
But Custom made plates were made in many materials such as titanium, Vitalium, PEEK, etc In this study we will compare the PEEK one with the titanium one to know which one is better in all aspects and if the PEEK one can overcome the shortcoming of the titanium one or not.
Conditions
- Mandibular Body Fractures
Interventions
- PROCEDURE
-
computer-assisted Polyether ether ketone (PEEK) custom made plates
computer-assisted Polyether ether ketone (PEEK) custom made plates in mandibular body fractures management
Sponsors & Collaborators
-
Cairo University
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2025-02-01
- Primary Completion
- 2026-07-20
- Completion
- 2026-08-31
Countries
- Egypt
More Related Trials
-
Patient Specific Plates Versus Conventional Miniplates for Treatment of Mandibular Body Fractures
NCT03608891 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Injection Molded PEEK Framework and Cobalt Chromium Framework Removable Partial Dentures Regarding Biting Force
NCT03777423 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Accuracy of Patient-Specific Plate for Reduction and Fixation of Mandibular Angle Fracture
NCT07231042 ·Status: COMPLETED ·Phase: NA
-
A Comparative Study Between Three Different Plating Techniques in Management of Mandibular Parasymphyseal Fractures.
NCT06323122 ·Status: COMPLETED
-
Comparison Between Injection Molded Polyetheretherketone (PEEK) Framework and Cobalt Chromium Framework Removable Partial Dentures Regarding Periodontal Health of Abutment Teeth
NCT03777345 ·Status: UNKNOWN ·Phase: NA
-
Patient Specific 3d Titanium Plate Versus Standard Two Mini Plates in the Fixation of Mandibular Angle Fractures (a Randomized Controlled Clinical Trial)
NCT07390734 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE4
-
Additive Versus Subtractive Manufacturing Techniques of Custom-Made Plates for the Fixation of Interforaminal Mandibular Fractures
NCT07263633 ·Status: COMPLETED ·Phase: NA
-
Patient Centered Outcomes and Marginal Bone Changes in CAD/CAM Metallic and (PEEK) Partial Denture Frameworks
NCT05622448 ·Status: COMPLETED ·Phase: NA
-
Comparative Study of Biting Force of Injection Molded PEEK and Bre.Flex for Removable Partial Dentures.
NCT03038737 ·Status: UNKNOWN ·Phase: NA
-
Muscle Activity Evaluation of Maxillary Bilateral Bounded Partial Denture Fabricated By Bre-Flex Versus Peek
NCT03507153 ·Status: UNKNOWN ·Phase: NA
-
Augmentation of Atrophic Mandibule Using Poly Ether Ether Ketone Mesh
NCT04017117 ·Status: UNKNOWN ·Phase: NA
-
Assessment of Efficacy of Prebent Titanium Mesh Versus Customized Poly-ether Ether Ketone Mesh for Three Dimensional Augmentation in Deficient Maxillary Ridge. a Randomized Controlled Clinical Trial.
NCT07040124 ·Status: COMPLETED ·Phase: NA
-
Oral Health Related Quality of Life in Cad Metallic and Poly Ether Ether Ketone (Peek) Partial Denture Frameworks in Mandibular Kennedy Class I Cases
NCT06789627 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Customized V Plate Versus Conventional Miniplates of Mandibular Angle Fracture
NCT03761524 ·Status: UNKNOWN ·Phase: NA
-
CAD/CAM Angle Fracture Reduction/Plate Guide and Customized 3D Grid Plate Versus Champy's Technique
NCT06392204 ·Status: COMPLETED ·Phase: NA
-
InterFlex Plate Versus Conventional Miniplates in the Management of Anterior Mandibular Fractures.
NCT06740292 ·Status: COMPLETED ·Phase: PHASE4
-
Biting Force in Heat Cured Acrylic Resin Versus CAD/CAM Maxillary Single Denture Bases
NCT02996123 ·Status: UNKNOWN ·Phase: NA
-
Poly Tetra Fluro Ethylene vs Native Collagen Membrane for Gbr in Anterior Maxilla
NCT03839615 ·Status: UNKNOWN ·Phase: NA
-
Retention of CAD Metallic and Poly Ether Ether Ketone (PEEK) Frameworks
NCT05670899 ·Status: UNKNOWN ·Phase: NA
-
Mandibular Overdentures vs All-on-4 With PEEK
NCT07137533 ·Status: RECRUITING
-
Two Years Follow up of Polyetheretherketone (PEEK) Sub-periosteal Implant Retaining Maxillary Fixed Prosthesis
NCT05193110 ·Status: COMPLETED ·Phase: NA
-
Guided Bone Regeneration Using a Mixture of Autogenous and Xenograft Particulate Versus Patient-Specific Sticky Bone for Horizontal Anterior Maxillary Defect
NCT07113886 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Z-shaped Bone Plates in Management of Mandibular Fractures
NCT07184762 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparative Trial of Custom-Made Titanium Plates Versus 3D Lambda Plates for Mandibular Subcondylar Fractures
NCT07231055 ·Status: COMPLETED ·Phase: NA
-
Retention of Peek and Bre.Flex Materials Maxillary Bilateral Bounded Removable Partial Dentures
NCT03025568 ·Status: UNKNOWN ·Phase: NA