Marginal Biofilm Distribution and Periodontal Response to Supragingival and Juxtagingival Aligner Designs
NCT07642037 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2026-07-16
Summary
* This prospective, longitudinal, within-person (split-mouth) clinical study evaluates the influence of two clear aligner trimming-line designs on marginal soft-tissue biofilm distribution and periodontal tissue response over a six-month period.
* Two trimming-line designs are compared. The supragingival design has a straight, horizontal edge that extends approximately 2 mm onto the marginal gingiva, resting in direct contact with the gingival surface but not entering the gingival sulcus. The juxtagingival design follows the scalloped contour of the gingival margin and terminates at the free gingival margin, without covering the gingiva and without entering the sulcus.
* Each participant receives both designs simultaneously, one per dental arch, and therefore serves as their own control. The assignment of each design to an arch is determined by the treating clinician according to the orthodontic treatment indications and is not randomized.
* The primary outcome is the percentage of sites with bleeding on probing per arch at six months. Secondary outcomes are bleeding on probing at three months, mean probing depth, maximum probing depth, and the Turesky-Quigley-Hein plaque index, with three exploratory photographic soft-tissue variables describing marginal gingival plaque presence, vestibular interdental papilla plaque presence, and the marginal demarcation pattern. Clinical and photographic assessments are performed at baseline (before aligner delivery), at three months, and at six months.
* All aligners are fabricated from a tri-layer clear aligner material (CA Pro, SCHEU-DENTAL GmbH, Iserlohn, Germany) by a single orthodontic laboratory.
Conditions
- Periodontal Diseases
- Dental Plaque
- Gingivitis
Interventions
- DEVICE
-
Supragingival aligner trimming-line
Clear aligner trimmed with a supragingival straight-cut margin extending approximately 2 mm onto the marginal gingiva, in direct contact with the gingiva but not entering the sulcus. Fabricated from CA Pro tri-layer thermoplastic material (SCHEU-DENTAL GmbH, Iserlohn, Germany; CE-marked) by Orto Performance Orthodontic Laboratory, Cluj-Napoca, Romania. The intervention under study is the trimming-line design, not the aligner material; material and thickness are identical to the comparator.
- DEVICE
-
Juxtagingival festooned aligner trimming-line
Clear aligner trimmed with a juxtagingival festooned margin following the scalloped gingival contour, terminating at the free gingival margin without covering the gingiva or entering the sulcus. Fabricated from CA Pro tri-layer thermoplastic material (SCHEU-DENTAL GmbH, Iserlohn, Germany; CE-marked) by Orto Performance Orthodontic Laboratory, Cluj-Napoca, Romania. The intervention under study is the trimming-line design, not the aligner material; material and thickness are identical to the comparator.
Sponsors & Collaborators
-
Orto Performance Orthodontic Laboratory, Cluj-Napoca, Romania (aligner fabrication)
collaborator UNKNOWN -
George Emil Palade University of Medicine, Pharmacy, Sciences and Technology of Targu Mures
lead OTHER
Principal Investigators
-
LUMINITA LAZAR, PhD, Professor · George Emil Palade University of Medicine, Pharmacy, Sciences, and Technology of Targu Mures, 38 Gheorghe Marinescu Street, 540139 Targu Mures, Romania
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- BASIC_SCIENCE
- Masking
- SINGLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2025-03-01
- Primary Completion
- 2026-07-15
- Completion
- 2026-07-15
Countries
- Romania
Study Locations
More Related Trials
-
Microbial Colonization in Three Dimensional (3D) Printed Orthodontic Clear Aligners
NCT07143370 ·Status: COMPLETED ·Phase: NA
-
Comparison of Oral Hygiene & Root Resorption During Orthodontic Treatment
NCT02745626 ·Status: COMPLETED ·Phase: NA
-
Bacterial Diversity Study Using 16S rRNA Sequencing of Periodontal Samples From Patients With Orthodontic Retainers
NCT07718061 ·Status: RECRUITING ·Phase: NA
-
Tooth Discoloration and Chairside Handling Time (Bonding-Debonding) in Flowable Versus Packable Composites for Clear Aligner Bonded Attachments: A Randomized Clinical Trial
NCT07234149 ·Status: RECRUITING ·Phase: NA
-
A Study to Compare Nighttime Aligners to Daytime Aligners
NCT06539676 ·Status: TERMINATED ·Phase: NA
-
Discomfort Perceived by a Cohort of Patients Treated With Aligners and Attachments Placed According to Two Different Protocols
NCT06218641 ·Status: WITHDRAWN ·Phase: NA
-
A Prospective Multicenter Clinical Investigation Evaluating the Accuracy of the Trimline Design When Treated With SureSmile® Aligners.
NCT07290790 ·Status: RECRUITING ·Phase: NA
-
Clinical Evaluation of Customized Attachment Composites in Clear Aligner Therapy
NCT07261735 ·Status: RECRUITING
-
Efficacy of Orthodontic Tooth Movement Using Beveled and Conventional Attachments in Aligners
NCT06873932 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
This Study Will Examine Shortened Treatment Wear Time for Patients With Mixed Dentition Using AirFlex Aligner, Sequential Dental Aligners.
NCT07220317 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Split-Mouth Comparison of Invisalign Attachments
NCT07215598 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Clinical Performance of Direct-Printed Versus Thermoformed Aligners
NCT07637227 ·Status: RECRUITING ·Phase: NA
-
Comparison of Single-Layer and Triple-Layer TPU MaxFlex Aligners After Intraoral Use
NCT07566533 ·Status: COMPLETED ·Phase: NA
-
Comparison of Plaque Removal Efficacy of Different Toothbrushes in Clear Aligner Patients
NCT07383636 ·Status: COMPLETED ·Phase: NA
-
Microbiological and Epithelial Evaluation Related to the Use of Orthodontic Thermoplastic Device
NCT02427763 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Pain and Discomfort With Anterior Versus Posterior Builds-up
NCT04105127 ·Status: UNKNOWN ·Phase: NA
-
Predictability of Orthodontic Tooth Movement With Invisalign Aligners
NCT05356780 ·Status: COMPLETED
-
3D-Printed vs Conventional Fixed Retainers After Orthodontic Treatment
NCT07730476 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Effects of Extraoral Photobiomodulation on the Rate of Orthodontic Alignment
NCT02267824 ·Status: COMPLETED ·Phase: NA
-
Development of Biofunctional 3D-Printed Orthodontic Aligners With Antimicrobial and Remineralizing Properties
NCT07603427 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
3D Printed vs. Milled Occlusal Splints in Dentistry
NCT07236294 ·Status: COMPLETED
-
Inflammation in Clear Aligners With and Without Attachments
NCT07506993 ·Status: RECRUITING
-
Mechanical Plaque Control and Gingivitis Reduction in Fixed Appliance Patients
NCT00681135 ·Status: COMPLETED ·Phase: NA
-
Patient-Specific Occlusal Splints Using MODJAW Kinematics
NCT07364552 ·Status: COMPLETED ·Phase: NA
-
Timing of Orthodontic Therapy and Regenerative Periodontal Surgery in Advanced Periodontitis Patients With Pathologic Tooth Migration
NCT02761668 ·Status: COMPLETED ·Phase: NA