3D-Printed vs Conventional Fixed Retainers After Orthodontic Treatment
NCT07730476 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 36
Last updated 2026-07-31
Summary
This randomized clinical trial aims to compare the clinical performance of two types of three-dimensionally printed fixed retainers (Cobalt-Chromium and Titanium Grade 5) with the conventional multistranded stainless steel fixed retainer following orthodontic treatment. Thirty-six participants will be randomly allocated into three parallel groups with a 1:1:1 allocation ratio. The primary outcome is post-treatment stability assessed by Little's Irregularity Index and lower arch dimensions. Secondary outcomes include bond failure rate and periodontal parameters over a 12-month follow-up period.
Conditions
- Orthodontic Relapse
- Malocclusion
Interventions
- DEVICE
-
Conventional Multistranded Stainless Steel Fixed Retainer
Conventional 0.0215-inch six-stranded stainless steel bonded fixed retainer.
- DEVICE
-
3D-Printed Cobalt-Chromium Fixed Retainer
Customized 3D-printed cobalt-chromium bonded fixed retainer fabricated from intraoral scans.
- DEVICE
-
3D-Printed Titanium Fixed Retainer
Customized 3D-printed titanium (Ti-6Al-4V) bonded fixed retainer fabricated from intraoral scans.
Sponsors & Collaborators
-
Minia University
lead OTHER
Principal Investigators
-
Salma A daabis, BDS · Minia University
-
Ahmed Sh Hashem, Professor · Minia University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 21 Years
- Max Age
- 35 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2026-08-01
- Primary Completion
- 2027-08-01
- Completion
- 2027-09-01
More Related Trials
-
Microbial Adherence, Surface Roughness, Effectiveness and Impact on Patients Between Conventional and 3D Printed Twin Block Appliances
NCT06944860 ·Status: RECRUITING ·Phase: NA
-
Microbial Colonization in Three Dimensional (3D) Printed Orthodontic Clear Aligners
NCT07143370 ·Status: COMPLETED ·Phase: NA
-
3D-Printed vs Conventional Acrylic Stabilization Splints in Young Adults With Bruxism and Temporomandibular Disorders: A Randomized Trial
NCT07433725 ·Status: RECRUITING ·Phase: NA
-
3D Printed vs. Milled Occlusal Splints in Dentistry
NCT07236294 ·Status: COMPLETED
-
Vacuum-formed Retainer Versus Bonded Retainer to Prevent Relapse After Orthodontic Treatment
NCT03070444 ·Status: COMPLETED ·Phase: NA
-
The Effectiveness of 3 Orthodontic Fixed Retention Schemes on Post-treatment Stability and Gingival Recession
NCT05926934 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Randomized Controlled Clinical Trial Of Oral Health-Related Quality Of Life In Patients Wearing Vacuum Formed Thermoplastic Retainers Constructed On Conventional Stone Models And On 3D Reconstructed Orthodontic Study Model
NCT02866617 ·Status: COMPLETED ·Phase: NA
-
Comparison of 3D Printed Resin Fixed Mandibular Retainer Versus Conventional Fixed Bonded Retainer
NCT07552155 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Effects of Different Storage Conditions on Removable Retainers
NCT05854953 ·Status: UNKNOWN ·Phase: NA
-
Effectiveness of Gold Fixed Retainers Compared to Conventional Stainless Steel Retainers
NCT07280455 ·Status: RECRUITING ·Phase: NA
-
Biological Reaction of Direct 3d Printed Retainers
NCT07098325 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Fixed Mandibular Retainer Using 3D Printed Positioning Tray Versus Direct Bonding Technique
NCT03572179 ·Status: COMPLETED ·Phase: NA
-
Comparison of Retention Characteristics of Immediate vs Delayed Retainer Delivery Using 3D Digital Model Analysis
NCT06292364 ·Status: RECRUITING ·Phase: NA
-
Comparison of Two Miniscrew Anchored Maxillary Protraction Protocols
NCT03712007 ·Status: COMPLETED ·Phase: NA
-
CAD/CAM Fixed Retainers vs. Conventional Multistranded Fixed Retainers in Orthodontic Patients. Comparison of Stability, Retainer Failure Rate, Adverse Effects, Cost-effectiveness, and Patient Satisfaction. A Randomized Controlled Clinical Trial
NCT04389879 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison of Dimensional Accuracy and Color Stability Between Direct 3D-printed and Thermoformed Retainers
NCT07053410 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Analysis of Orthodontic Tooth Movement Using 3D Imaging
NCT03398798 ·Status: COMPLETED ·Phase: NA
-
RCT for the Effectiveness of 3 Orthodontic Retention Schemes on Post-treatment Stability and Gingival Recession
NCT02742493 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Precision Orthodontics: Virtual Treatment Planning for Orthodontic Braces
NCT04002999 ·Status: UNKNOWN ·Phase: NA
-
Clinical Performance of a New Esthetic, Self-ligating Orthodontic Bracket
NCT02959671 ·Status: COMPLETED ·Phase: NA
-
Success Rate of the Miniscrews in the Mandibular Buccal Shelf
NCT05280678 ·Status: COMPLETED ·Phase: NA
-
Orthodontic Treatment in Adolescents With Crowding and Displaced Teeth
NCT05664282 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Treatment Outcome of Elastomeric and Nickel-Titanium Separators in Tooth Separation
NCT07591454 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparing Clinical Application of Innovatedly Made Transpalatal Arch (TPA) From 3D Reconstructed Model and Conventionally Made TPA
NCT03755622 ·Status: UNKNOWN ·Phase: NA
-
Comparison of the Effect of Two Types of Fixed Retainers on the Health of the Gums
NCT01314729 ·Status: UNKNOWN ·Phase: PHASE3