Changes in Pulpal Blood Flow Between Conventional and Self-ligating Fixed Orthodontic Brackets During Leveling and Alignment Stage
NCT03780764 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 22
Last updated 2018-12-20
Summary
\- Evaluate and compare initial changes in PBF between conventional and self-ligating fixed orthodontic brackets during leveling and alignment stage using 0.016" Nickle titanium (NiTi) and 0.016X0.022" NiTi archwires at different time intervals (20min, 24h, 72h, 1 week and 1 month) of initial arch wire placement.
Conditions
- Orthodontic Appliances
Interventions
- OTHER
-
A Pre-adjusted edgewise brackets: 3M Gemini Unitek, 0.022" Roth prescription brackets
A pre-adjusted edgewise fixed appliance (3M Gemini Unitek, 0.022" Roth prescription brackets) on one side of lower arch. The standardized bonding technique was applied according to the manufacturer's instructions. Teeth alignment was initiated using round 0.016" NiTi arch wire until 0.016X0.022" NiTi was reached. The NiTi arch wires were placed into brackets slots and tied with elastomers (figure of 8).
- OTHER
-
Self- ligating brackets: Unitek™ Gemini SL Self-Ligating Brackets, 0.022" Roth prescription brackets
Self-ligating brackets (Unitek™ Gemini SL Self-Ligating Brackets, 0.022" Roth prescription brackets) on the other side of lower arch. The standardized bonding technique was applied according to the manufacturer's instructions. Teeth alignment was initiated using round 0.016" NiTi arch wire until 0.016X0.022" NiTi was reached. The NiTi arch wires were placed into brackets slots and held in place by bracket's gate in the self-ligating brackets side.
Sponsors & Collaborators
-
Jordan University of Science and Technology
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 16 Years
- Max Age
- 22 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-06-01
- Primary Completion
- 2017-12-31
- Completion
- 2018-05-01
Countries
- Jordan
Study Locations
More Related Trials
-
The Effect of OrthoPulse™ Photobiomodulation on Tooth Movement and Treatment Time When Used With Invisalign Treatment
NCT02954133 ·Status: UNKNOWN ·Phase: NA
-
Impact of Injectable Platelet Rich Fibrin Versus Low-intensity Pulsed Ultrasound on Different Orthodontic Tooth Movements During Clear Aligner Therapy
NCT06276985 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Influence of Four Orthodontic Bracket Prescriptions in Arch Width and Torque
NCT04043013 ·Status: COMPLETED ·Phase: NA
-
The Effect of OrthoPulse™ on the Rate of Orthodontic Tooth Movement
NCT02267811 ·Status: COMPLETED ·Phase: NA
-
Predictability of Orthodontic Tooth Movement With Invisalign Aligners
NCT05356780 ·Status: COMPLETED
-
Analysis of Orthodontic Tooth Movement Using 3D Imaging
NCT03398798 ·Status: COMPLETED ·Phase: NA
-
Evaluating the Effect of Injectable Platelet-rich Fibrin on Accelerating Orthodontic Tooth Movement
NCT06302296 ·Status: RECRUITING ·Phase: NA
-
3D-Printed Vs Thermoformed Retainers: Comparison of Post-Treatment Stability, Changes in Mechanical Properties and Patients' OHRQoL
NCT05968625 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Subjective Experiences Between Patients Receiving Clear Aligners or Fixed Appliances
NCT03656471 ·Status: COMPLETED
-
Comparison of Precision in Brackets Position in Two Indirect Bonding Materials
NCT05483114 ·Status: UNKNOWN ·Phase: NA
-
Comparing Clinical Application of Innovatedly Made Transpalatal Arch (TPA) From 3D Reconstructed Model and Conventionally Made TPA
NCT03755622 ·Status: UNKNOWN ·Phase: NA
-
Microbial and Periodontal Changes Associated With Conventional Versus Self Ligating Brackets
NCT02436525 ·Status: UNKNOWN ·Phase: NA
-
The Effects of Extraoral Photobiomodulation on the Rate of Orthodontic Alignment
NCT02267824 ·Status: COMPLETED ·Phase: NA
-
Incidence of White Spot Lesions Around Ceramic Brackets Compared With Metal Brackets
NCT05764187 ·Status: COMPLETED ·Phase: NA
-
Periodontal Ligament Stress Level and Tooth Movement
NCT00099814 ·Status: COMPLETED ·Phase: PHASE1
-
Comparison of the Clinical Efficacy of the Lingual Brackets and Labial Brackets in the Leveling Phase
NCT04357067 ·Status: COMPLETED ·Phase: NA
-
Transfer Accuracy of 3D-printed Indirect Bonding Trays
NCT04683874 ·Status: COMPLETED ·Phase: NA
-
The Effect of OrthoPulse Photobiomodulation on the Rate of Tooth Movement During Alignment With Fixed Appliances
NCT03202355 ·Status: TERMINATED ·Phase: NA
-
Difference Between Pressing and Vacuum Techniques in Fabrication of Orthodontic Aligners in Cases With Spacing: A Cross-sectional Study
NCT06231875 ·Status: RECRUITING
-
3D Printed vs. Milled Occlusal Splints in Dentistry
NCT07236294 ·Status: NOT_YET_RECRUITING
-
The Effectiveness of 3 Orthodontic Fixed Retention Schemes on Post-treatment Stability and Gingival Recession
NCT05926934 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of the Efficacy of Injectable Platelet-rich Plasma in Tooth Movement Acceleration With Clear Aligner
NCT07103551 ·Status: NOT_YET_RECRUITING ·Phase: PHASE3
-
Variation in Rate of Orthodontic Tooth Movement in Response to Platelet Rich Plasma Therapy
NCT04016727 ·Status: UNKNOWN ·Phase: PHASE4
-
Efficiency, Efficacy, Periodontal & Occlusal Outcomes for Aligners Versus Fixed Orthodontic Appliances in Crowded Incisor Treatment
NCT06731465 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Comparison of the Effect of Two Types of Fixed Retainers on the Health of the Gums
NCT01314729 ·Status: UNKNOWN ·Phase: PHASE3