Evaluation of Different Sizes of Left-Sided Double-Lumen Tubes for Thoracic Surgery in a Tertiary Level Teaching Hospital
NCT07373171 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60
Last updated 2026-01-28
Summary
Double lumen tubes (DLT) have become standard of care for one lung ventilation in thoracic and esophageal surgeries. Selection of accurate size of DLT is important to achieve proper one lung ventilation, prevent trauma to airway, easy intubation, prevention of displacement of DLT and adequate oxygenation intraoperatively. There are no definitive guidelines to select the correct size of DLT. The aim of this study is to observe if there is any difference in the number of intubation attempts, intraoperative oxygenation and postoperative sore throat while using 35 Fr DLT size and other DLT size. The research will be conducted between Ashoj 1st 2082 to Chaitra 30 2082 at Manmohan Cardiothoracic Vascular and Transplant Center(MCVTC). Fifty patients aged more than eighteen years undergoing thoracic surgery requiring One Lung Ventilation(OLV) with left sided DLT will be selected for the study. Participants will be randomly assigned to 35 Fr DLT size group or DLT size group according to the height. Patients in both the groups will be given the samepreoperative care, intraoperative care and postoperative care. Besides patient's demography, diagnosis and operative procedure; number of intubation attempts, modified Cromack-Lehane(CL) grade, size of DLT, intraoperative oxygen saturation SpO₂ and postoperative sore throat on day of surgery and first postoperative day will be recorded. Statistical analysis will be done using t- test for independent variable, confidence interval for outcome of sore throat, significance of difference for number of male and female; rates, risk ratio and odds ratio will be calculated using 2x2 contingency table. P ≤ 0.05 will be considered statistically significant. Our expected outcome is 35 Fr DLT are easier to intubate, does not affect intraoperative oxygenation and decrease the incidence of postoperative sore throat.
Conditions
- Lung Adenocarcinoma
- Lung Abscess
Interventions
- DEVICE
-
Intubation of patients undergoing thoracic surgery with left sided double lumen tube
During the intervention Integrity of the tracheal and bronchial cuffs will be checked first. Lubrication of the outside of the 35 Fr DLT will be done using 2.5% lidocaine jelly and intubating stylet will be inserted (can be preshaped to aid placement of the DLT). Direct laryngoscopy will be done to visualize the glottis. DLT will be advanced till the endobronchial cuff is passed beyond the vocal cords and then the stylet is removed. DLT will be rotated 90 anticlockwise and the tracheal cuff is inserted beyond the glottis until resistance is encountered.
Sponsors & Collaborators
-
Tribhuvan University, Nepal
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-01-31
- Primary Completion
- 2026-03-31
- Completion
- 2026-08-31
Countries
- Nepal
Study Locations
More Related Trials
-
Fiberoptic Bronchoscope of Double Lumen Tube and Single Lumen Tube in Patients With Semi-regid Neck Collar.
NCT03392766 ·Status: COMPLETED ·Phase: NA
-
Left Double Lumen Tube Selection
NCT06457763 ·Status: COMPLETED ·Phase: NA
-
Analysis of Breath Sound During Thoracic Surgery
NCT05250635 ·Status: UNKNOWN
-
Compare a New Method and Formula as a Guide for the Intubation of a Left-sided Double-lumen Tube
NCT03545737 ·Status: COMPLETED
-
Comparison of Double Lumen Tube Location Verification Techniques in Single Lung Ventilation
NCT07107893 ·Status: COMPLETED
-
Endobronchial Intubation of Double-lumen Tube: Conventional Method vs Fiberoptic Bronchoscope Guide Method
NCT03368599 ·Status: COMPLETED ·Phase: NA
-
Clinical Application of Right Visual Double Lumen Tube in Thoracoscopic Surgery for Adult Patients
NCT07362797 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Comparison of Glidescope® and the Direct Laryngoscopy in the Insertion of the Double Lumen Endotracheal Tube
NCT01424605 ·Status: COMPLETED ·Phase: NA
-
Double-lumen Tubes (DLT) - Health Economic Study
NCT03817879 ·Status: COMPLETED ·Phase: NA
-
Repositioning Method for Left-sided Double Lumen Tubes
NCT01371773 ·Status: COMPLETED ·Phase: NA
-
C-MAC Video Laryngoscope for Double-Lumen Intubation
NCT07284251 ·Status: COMPLETED ·Phase: NA
-
Comparison of Different Bending Mode for Double-lumen Endotracheal Tube Intubation
NCT01605591 ·Status: COMPLETED ·Phase: NA
-
Macintosh Versus GlideScope Versus C-MAC for Double Lumen Endotracheal Intubation
NCT05091281 ·Status: COMPLETED ·Phase: NA
-
Comparisons of Novel Double-lumen Endobronchial Tube for Blind Lung Isolation Technique With Conventional Double-lumen Endobronchial Tube in Patients Undergoing One-lung Ventilation
NCT03782090 ·Status: COMPLETED ·Phase: NA
-
Comparison of Fiberoptic Bronchoscopic Intubation Between Silicone and Polyvinylchloride Double Lumen Tube.
NCT03889847 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Glidescope and Macintosh Laryngoscope for Double Lumen Endotracheal Tube Intubation
NCT01404780 ·Status: COMPLETED ·Phase: NA
-
Double-Lumen Tube With or Without a Carinal Hook
NCT00969683 ·Status: COMPLETED ·Phase: NA
-
The Effects of Flexible Intubating Stylet in the Accurate Placement of Double-lumen Endobronchial Tube
NCT02364622 ·Status: COMPLETED ·Phase: NA
-
Application of Bronchial Blocker in Minimally Invasive Cardiac Surgery
NCT03505242 ·Status: UNKNOWN ·Phase: NA
-
New Formula for Selection of Proper Size of Endotracheal Tube (ETT) in Children: Ultrasonographic Examination
NCT01227161 ·Status: COMPLETED
-
Influence of Tracheal-bronchial Anatomy Changes on Multi-detector Computed Tomography Scan of the Chest Upon Placement of Left-Sided Double Lumen Endotracheal Tube
NCT03838653 ·Status: COMPLETED
-
The Efficacy of Trachway (R) Intubating Stylet in the Insertion of the Double Lumen Endobronchial Tube
NCT01517204 ·Status: COMPLETED ·Phase: NA
-
Ultrasound for Double Lumen Endotracheal Tube
NCT02556853 ·Status: TERMINATED ·Phase: NA
-
The Pretreatment of a Left-sided Double-lumen Tube to Prevent Its Misplacement to the Right Mainstem Bronchus
NCT01818128 ·Status: COMPLETED ·Phase: NA
-
Bronchial Blocker for One-lung Ventilation in Cardiac Surgery
NCT02729610 ·Status: UNKNOWN ·Phase: PHASE4