Effect of Small Double-lumen Tube on the Intubation Time of Thoracoscopic Pulmonectomy in Asian Women
NCT07097584 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 180
Last updated 2026-04-23
Summary
The purpose of this experiment is to verify whether selecting a double-lumen tube one size smaller based on the traditional personalized method can shorten the intubation time without increasing ventilation complications when performing tracheal intubation for thoracic surgery in Asian women.Patients receive double-lumen tubes of a size selected based on the traditional personalized method or one size smaller than that chosen by the traditional method during tracheal intubation. The primary outcome is the time duration required to complete Double-lumen tube intubation and positioning.
Conditions
- Women
- Asian
- Thoracic Surgery With One-lung Ventilation
Interventions
- DEVICE
-
Selecting the size of a Left Double-lumen endobronchialtube one size smaller than the traditional method
During tracheal intubation,choose a Left Double-lumen Endobronchial Tubethat is one size smaller than the traditional method.In this study, all patients planned to be enrolled are female. In experimental group the relationship between height and size is roughly as follows: For patients with a height between 152 - 165 cm, a 32Fr (French) tube is often selected. For patients with a height between 165 - 177 cm, a 35Fr tube is often selected. For patients with a height of more than 177 cm, a 37Fr tube is often selected.
- DEVICE
-
Selecting the size of a Left Double-lumen endobronchialtube according to traditional methods
During tracheal intubation,choose the regular Left Double-lumen endobronchial tube according to the traditional method. The selection of double-lumen tube sizes using traditional methods relies on two factors: height and gender. In this study, all patients planned to be enrolled are female, so the traditional corresponding relationship is roughly as follows: For patients with a height of less than 152 cm, a 32Fr (French) tube is often selected. For patients with a height between 152 - 165 cm, a 35Fr tube is often selected. For patients with a height between 165 - 177 cm, a 37Fr tube is often selected. For patients with a height of more than 177 cm, a 39Fr tube is often selected.
Sponsors & Collaborators
-
Zhejiang Cancer Hospital
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- FEMALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-07-15
- Primary Completion
- 2025-12-22
- Completion
- 2026-01-23
Countries
- China
Study Locations
More Related Trials
-
Comparison of Double Lumen Tube Location Verification Techniques in Single Lung Ventilation
NCT07107893 ·Status: COMPLETED
-
A Clinical Comparison of Two New Bronchial Blockers vs. Double Lumen Tubes in One Lung Ventilation
NCT02983149 ·Status: COMPLETED ·Phase: NA
-
Application of Bronchial Blocker in Minimally Invasive Cardiac Surgery
NCT03505242 ·Status: UNKNOWN ·Phase: NA
-
Effects of Tracheal Tube Size on Pulmonary Aspiration
NCT01058928 ·Status: UNKNOWN
-
Randomised Controlled Trial of Intubation, Comparing Pentax AWS Against Macintosh Laryngoscope.
NCT01029756 ·Status: UNKNOWN ·Phase: NA
-
Bougies as Aid for Endotracheal Intubation Via Video Laryngoscopy During Continuous Chest Compressions
NCT05689125 ·Status: COMPLETED ·Phase: NA
-
Modified Angled Tube vs. Conventional Angled Tube in Double-lumen Endotracheal Tube Intubation
NCT02190032 ·Status: COMPLETED ·Phase: NA
-
The Efficacy of Trachway (R) Intubating Stylet in the Insertion of the Double Lumen Endobronchial Tube
NCT01517204 ·Status: COMPLETED ·Phase: NA
-
Investigation of a 3 oz Water Protocol on Patients With Tracheostomies
NCT06120790 ·Status: RECRUITING
-
Insertion Time Over Fiberoptic Bronchoscope of Double Lumen Tube and Single Lumen Tube
NCT03173443 ·Status: COMPLETED ·Phase: NA
-
A Comparison the Intubation of a Left Sided Double Lumen Tube and Uniblocker
NCT03392922 ·Status: COMPLETED ·Phase: NA
-
Stylet Shape in Simulated Endotracheal Intubation by Medical Students
NCT06525662 ·Status: RECRUITING ·Phase: NA
-
Nonintubated Versus Intubated Anesthesia in Video-assisted Thoracic Surgery
NCT04253795 ·Status: SUSPENDED ·Phase: NA
-
Flexible Reinforced Laryngeal Mask Airway Versus Endotracheal Tube for Childhood Adenotonsillectomy
NCT06356298 ·Status: COMPLETED ·Phase: PHASE2
-
Left Double Lumen Tube Selection
NCT06457763 ·Status: COMPLETED ·Phase: NA
-
3D-printed Reconstruction Automated Matching System Predicts Size of Double-lumen Tube: a Prospective Double-blinded Randomized Controlled Trial
NCT05899270 ·Status: UNKNOWN ·Phase: NA
-
Analysis of Breath Sound During Thoracic Surgery
NCT05250635 ·Status: UNKNOWN
-
Speaking Valve Combined With Airway Pressure Predicts Upper Airway Patency in Adult Tracheotomized Patients
NCT06521320 ·Status: COMPLETED ·Phase: NA
-
Evaluation on the Proper Size of the Nasotracheal Tube and Depth in Nasotracheal Intubation: a Preliminary Study
NCT02876913 ·Status: COMPLETED
-
THRIVE and Non-intubated Thoracic Surgery
NCT03275428 ·Status: UNKNOWN
-
Endobronchial Intubation of Double-lumen Tube: Conventional Method vs Fiberoptic Bronchoscope Guide Method
NCT03368599 ·Status: COMPLETED ·Phase: NA
-
Ventilation Efficacy of Size 3 or Size 4 I-gel in Female Patient Weighing 50 to 60 Kilograms
NCT03528590 ·Status: UNKNOWN ·Phase: NA
-
The Effect of The Use of a Videolaryngoscope and/or Stylet on Intubation Time in Obese Patients
NCT05026671 ·Status: COMPLETED ·Phase: NA
-
Retrograde Light Target Tracheal Intubation Technique:Clinical Comparison With Direct Pharyngoscopic Tracheal Intubation
NCT01116999 ·Status: COMPLETED ·Phase: NA
-
Which is the Best Bedside Test to Detect Endobronchial Intubation?
NCT01232166 ·Status: COMPLETED ·Phase: NA