Accuracy Validation of Belun Oxygen Saturation Pulse Oximeter FDA Submission Study
NCT03439306 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 11
Last updated 2018-02-20
Summary
The purpose of this study is to evaluate the oxygen saturation accuracy performance of Belun Ring Oximeter placed on the index fingers during non-motion conditions
Conditions
Interventions
- DEVICE
-
Pulse Oximeter
The Pulse Oximeter are placed on the left and right Index fingers of each subject of the healthy adult volunteer group to evaluate the SpO2 accuracy performance.
Sponsors & Collaborators
-
Clinimark, LLC
collaborator OTHER -
Belun Technology Company Limited
lead OTHER
Principal Investigators
-
Arthur Ruiz Cabrera, M.D. · Clinimark, LLC
Eligibility
- Min Age
- 18 Years
- Max Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-03-15
- Primary Completion
- 2017-03-17
- Completion
- 2017-03-17
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Hypoxia Blood Validation in Multiple Pulse Oximeters
NCT00881829 ·Status: UNKNOWN
-
SpO2 Accuracy Comparison of Medline ReNewal Sensors to Arterial Blood CO-Oximetry
NCT03565679 ·Status: COMPLETED ·Phase: NA
-
Accuracy Validation of a Pulse Oximetry Monitor
NCT02506010 ·Status: WITHDRAWN
-
Pulse Oximeter Accuracy During Stable Hypoxia Plateaus
NCT06460246 ·Status: COMPLETED ·Phase: NA
-
The Sunrise SpO2 and Pulse Rate Accuracy Validation Study
NCT05386836 ·Status: COMPLETED ·Phase: NA
-
Finger Pulse Oximeters in Hosptial Setting
NCT06994663 ·Status: COMPLETED
-
Oxitone Sp02 Hypoxia Test Versus Reference Pulse Oximetry
NCT02870179 ·Status: COMPLETED
-
SpO2 Accuracy Low Saturation Validation of the OxySoftN Sensor
NCT04811963 ·Status: COMPLETED
-
Induced Hypoxia Study for Validation of SpO2 Accuracy
NCT00788983 ·Status: COMPLETED
-
RDS MultiSense® SpO2 Calibration
NCT05466942 ·Status: COMPLETED ·Phase: NA
-
N600X Low Saturation Accuracy Validation
NCT05532670 ·Status: COMPLETED
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT04324385 ·Status: COMPLETED
-
Respiratory Rate Accuracy - Healthy Adults
NCT03223870 ·Status: COMPLETED
-
SpO2 Accuracy Validation of the OxySoft Sensor Via Reference CO-Oximetry Motion Study
NCT04559763 ·Status: COMPLETED
-
Accuracy of SpO2 for Noninvasive Pulse Oximeter Sensor (LNCS ADTX)
NCT03125018 ·Status: COMPLETED ·Phase: NA
-
SpO2 Accuracy of Noninvasive Disposable Pulse Oximeter Sensor
NCT05245526 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters During Profound Hypoxia
NCT05790616 ·Status: UNKNOWN ·Phase: NA
-
SpO2 Accuracy of Noninvasive Disposable Pulse Oximeter Sensor With Motion Conditions
NCT05264116 ·Status: COMPLETED ·Phase: NA
-
Controlled Acute Hypoxia Study Comparing Pulse Oximetry to Arterial Blood Samples During Motion
NCT02247765 ·Status: COMPLETED ·Phase: PHASE3
-
Accuracy of Continuous SpO2 Measurement in Adults
NCT01183338 ·Status: WITHDRAWN
-
Accuracy of Pulse Oximeter With Profound Hypoxia
NCT05693168 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters in Profound Hypoxia
NCT05920278 ·Status: COMPLETED
-
OM2 Motion Verification Study
NCT06415786 ·Status: COMPLETED
-
Accuracy of ScanWatch Pulse Oximeter With Profound Hypoxia
NCT04380389 ·Status: COMPLETED ·Phase: NA
-
Desaturation Validation of INVSENSOR00028
NCT03704636 ·Status: COMPLETED ·Phase: NA