RDS MultiSense® SpO2 Calibration
NCT05466942 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 16
Last updated 2024-12-19
Summary
Data will be collected with the MultiSense® pulse oximetry system during non-motion conditions over the range of 70-100%. A Clinimark reference system, previously correlated to arterial blood CO-Oximetry will be the basis for comparison. A minimum of fifteen (15) up to fifty (50) healthy adult subjects, ranging in pigmentation from light to dark, with at least six (6) subjects with dark pigmentation (Fitzpatrick 5-6), will be enrolled in the study to meet the study design requirements defined by ISO 80601-2-61 and by the FDA's Guidance for Pulse Oximeters (March 4, 2013). SpO2 data will be evaluated during non-motion conditions. SpO2 data will be evaluated during stable step plateaus of induced hypoxic levels. The investigational device will be placed on the thorax of the subjects (patch on the upper back and external electrode on the right pectoral). Simultaneous data collection will be set up for the reference and the systems under test.
Conditions
Interventions
- DEVICE
-
Pulse Oximeter, Respiratory Rate, Heart Rate
Measurement of physiological parameters
Sponsors & Collaborators
-
Clinimark, LLC
collaborator OTHER -
Rhythm Diagnostic Systems
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2022-03-15
- Primary Completion
- 2022-03-17
- Completion
- 2022-10-20
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Accuracy of SpO2 for Noninvasive Pulse Oximeter Sensor (LNCS ADTX)
NCT03125018 ·Status: COMPLETED ·Phase: NA
-
SpO2 Accuracy Validation of the OxySoft Sensor Via Reference CO-Oximetry Motion Study
NCT04559763 ·Status: COMPLETED
-
SpO2 Hypoxia Accuracy Validation Study
NCT03348189 ·Status: COMPLETED
-
Accuracy Validation of the Cadwell Pulse Oximetry System
NCT02842476 ·Status: COMPLETED
-
Oxitone Sp02 Hypoxia Test Versus Reference Pulse Oximetry
NCT02870179 ·Status: COMPLETED
-
SpO2 Accuracy Comparison of Medline ReNewal Sensors to Arterial Blood CO-Oximetry
NCT03565679 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT05322382 ·Status: COMPLETED ·Phase: NA
-
Belun SpO2 Accuracy Comparison to Arterial Blood CO-Oximetry
NCT04873947 ·Status: COMPLETED
-
Induced Hypoxia Study for Validation of SpO2 Accuracy
NCT00788983 ·Status: COMPLETED
-
Comparison of Normal Readings and Repeatability Across Skin Colors
NCT01326819 ·Status: COMPLETED
-
Pulse Oximeter Accuracy During Stable Hypoxia Plateaus
NCT06460246 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Noninvasive Pulse Oximeter Sensor (MightySat RX)
NCT03125135 ·Status: COMPLETED ·Phase: NA
-
Respiratory Rate Accuracy - Healthy Adults
NCT03223870 ·Status: COMPLETED
-
Controlled Acute Hypoxia Study Comparing Pulse Oximetry to Arterial Blood Samples During Motion
NCT02247765 ·Status: COMPLETED ·Phase: PHASE3
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT05139693 ·Status: COMPLETED
-
Pulse CO-Oximetry Noninvasive Monitoring and Laboratory Measurements of Subject Blood Samples
NCT01638455 ·Status: COMPLETED ·Phase: NA
-
Clinical Performance of Masimo INVSENSOR00040
NCT05332392 ·Status: COMPLETED ·Phase: NA
-
Accuracy Validation of Belun Oxygen Saturation Pulse Oximeter FDA Submission Study
NCT03439306 ·Status: COMPLETED
-
Accuracy of Pulse Oximeters During Profound Hypoxia
NCT05790616 ·Status: UNKNOWN ·Phase: NA
-
SpO2 Accuracy of Noninvasive Pulse Oximeter Sensor With Motion Conditions
NCT06149416 ·Status: COMPLETED ·Phase: NA
-
Pulse Oximeter Accuracy in Healthy Humans During Hypoxia
NCT06142019 ·Status: RECRUITING
-
Accuracy of Oxygen Saturation (SpO2) Noninvasive Pulse Oximeter Sensor (RD Disposable) Under Motion Conditions
NCT03124784 ·Status: COMPLETED ·Phase: NA
-
OM2 Motion Verification Study
NCT06415786 ·Status: COMPLETED
-
Respiratory Rate Validation Study - ChroniSense Polso
NCT05246358 ·Status: COMPLETED ·Phase: NA
-
SpO2 Validation of Noninvasive Red Diamond Disposable Pulse Oximeter Sensor
NCT03124602 ·Status: COMPLETED ·Phase: NA