Accuracy of Pulse Pressure Variations Measured by a Non Invasive Digital Device to Predict Fluid Responsiveness
NCT03066388 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 6
Last updated 2017-02-28
Summary
It has been well established that only 40 to 60% of the patients hospitalized for inflammatory response syndrome (SIRS) positively respond to volume expansion (VE). The fluid responsiveness is usually estimated by assessing VE-induced change in stroke volume (SV). To guide prescriptions and possibly avoid deleterious effects of inappropriate VE, several clinical studies demonstrated that invasive dynamic indices based on heart-lung interactions permit an accurate prediction of the hemodynamic effects induced by VE.
Mechanical ventilation induces cyclic changes in intrathoracic and transpulmonary pressures that transiently affect venous return, right and left ventricular preload, resulting in pronounced cyclic changes in SV in preload-dependent, but not in preload-independent patients. These cyclic changes in SV can be evaluated by the cyclic changes in arterial pulse pressure. Several studies have shown that pulse pressure variation is able to predict fluid responsiveness in patients in the operating room and intensive care unit (ICU).
However, this technique requires percutaneous arterial catheterization, which is associated with several rare but serious complications (thrombosis, infections, pseudoaneurysm,hematoma, and bleeding).
A method for assessing noninvasive arterial blood pressure using an electropneumatic control loop was introduced by Penaz in 1973. Briefly, the blood volume in a finger is measured and kept constant by applying corresponding external pressure. The continuously changing external pressure needed to keep the volume constant directly corresponds to the arterial pressure and, therefore can be used as continuous measurement of arterial blood pressure. Numerous studies evaluating the accuracy of this technology, e.g., Finapres™ (Ohmeda Monitoring Systems, Englewood, CO), and more recently of the Infinity CNAP™ SmartPod (Dräger Medical AG \& Co.KG, Lübeck, Germany).
The basic operating principle of the CNAP™ is similar to the Finapres™, but CNAP™ uses multiple control loops. It has recently been shown that CNAP provides real-time estimates of mean arterial blood pressure (MAP) comparable with those measured by an invasive intraarterial catheter system during general anaesthesia.
The accuracy of the measures and the respiratory variations in pulse pressure obtained with the CNAP system have not yet been studied in ICU.
Conditions
- Systemic Inflammatory Response Syndrome
- Circulatory Failure
- Mechanical Ventilation
Interventions
- OTHER
-
Pulse pressure variations
Stroke volume and, pulse pressure variations obtained by noninvasive (ΔPPCNAP) and invasive (ΔPPART) devices are recorded immediately before and after volume expansion (VE), performed as a 30-minute infusion of 500 mL of 4% gelatin.
Sponsors & Collaborators
-
University Hospital, Lille
lead OTHER
Principal Investigators
-
Sébastien Preau, MD,PhD · University Hospital, Lille
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-04-30
- Primary Completion
- 2013-06-30
- Completion
- 2013-06-30
Countries
- France
Study Locations
More Related Trials
-
Predicting Volume Response Study
NCT01656954 ·Status: COMPLETED
-
Ventricular-Vascular Coupling in Heart Failure
NCT00207220 ·Status: COMPLETED
-
Viability of Pulsioflex Monitoring in ICU
NCT04911985 ·Status: COMPLETED
-
Pressure Variability Study
NCT02943941 ·Status: COMPLETED ·Phase: NA
-
Is Mitral Velocity Time-integral a Marker of Preload-responsiveness in Patients With Acute Circulatory Failure?
NCT05538637 ·Status: COMPLETED
-
Pressure-Volume Loop Assessment in Valvular Heart Disease
NCT07112391 ·Status: RECRUITING
-
Evaluation of the Association Between Right Atrial Reservoir Strain Variation and Fluid Responsiveness in Patients With Septic Shock
NCT06492044 ·Status: RECRUITING ·Phase: NA
-
Use of the SonoSite Probe for Measuring Jugular Venous Pressure
NCT03815188 ·Status: COMPLETED
-
An Exploratory Clinical Study Non-invasive Monitoring of Cardiac Outputs
NCT05734664 ·Status: COMPLETED ·Phase: NA
-
Mean Systemic Filling Pressure and Heart Performance Predicting Fluid Responsiveness in Aortic Valve Replacement
NCT02778620 ·Status: COMPLETED
-
Blood Volume and Hemodynamic Analysis in Patients With Chronic Heart Failure
NCT02120014 ·Status: COMPLETED ·Phase: NA
-
Echocardiographic Evaluation of RV Injury in the ICU
NCT05525936 ·Status: NOT_YET_RECRUITING
-
Automated Inferior Vena Cava Collapsibility Index Fluid Responsiveness in Ventilated Patients After Cardiac Surgery.
NCT05283590 ·Status: UNKNOWN
-
Preload Dependency by Impedance Cardiography After Cardiac Surgery
NCT02132871 ·Status: COMPLETED
-
Prognostic Value of Right Ventricular-pulmonary Arterial Coupling Assessed by Echocardiography in Septic Patients
NCT06887140 ·Status: NOT_YET_RECRUITING
-
Predicting Fluid Responsiveness in Mechanically Ventilated Critically Ill Children Using Transthoracic Echocardiography
NCT05054452 ·Status: COMPLETED ·Phase: NA
-
FLuid Responsiveness Prediction Using EXtra Systoles
NCT03002129 ·Status: COMPLETED ·Phase: NA
-
Respiratory Variations of the Diameter of Superior Vena Cava for Predicting Fluid Responsiveness After Cardiac Surgery
NCT03393897 ·Status: COMPLETED
-
Pulse Wave Analysis in Advanced Heart Failure
NCT01642927 ·Status: WITHDRAWN
-
Validation of Capnography as a Predictor of Cardiac Output Change as Measured by FloTrac
NCT01880684 ·Status: COMPLETED
-
Protective Effect of EECP Against Negative Inflammatory Response and Organ Dysfunction After Cardiovascular Surgery
NCT06728605 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Establishing Correlation Between Non-invasive Pulmonary Blood Pressure Readings and Swan-Ganz Results
NCT04509089 ·Status: COMPLETED ·Phase: NA
-
Ventricular Stimulation as Predictor of Hypovolemia After Cardiac Surgery
NCT03926910 ·Status: COMPLETED ·Phase: NA
-
Assessment of Right Ventricular 2d-strain in Acute Respiratory Distress Syndrome
NCT02638844 ·Status: COMPLETED
-
Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions
NCT05508711 ·Status: COMPLETED