Accuracy of Pulse Pressure Variations Measured by a Non Invasive Digital Device to Predict Fluid Responsiveness

NCT03066388 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 6

Last updated 2017-02-28

No results posted yet for this study

Summary

It has been well established that only 40 to 60% of the patients hospitalized for inflammatory response syndrome (SIRS) positively respond to volume expansion (VE). The fluid responsiveness is usually estimated by assessing VE-induced change in stroke volume (SV). To guide prescriptions and possibly avoid deleterious effects of inappropriate VE, several clinical studies demonstrated that invasive dynamic indices based on heart-lung interactions permit an accurate prediction of the hemodynamic effects induced by VE.

Mechanical ventilation induces cyclic changes in intrathoracic and transpulmonary pressures that transiently affect venous return, right and left ventricular preload, resulting in pronounced cyclic changes in SV in preload-dependent, but not in preload-independent patients. These cyclic changes in SV can be evaluated by the cyclic changes in arterial pulse pressure. Several studies have shown that pulse pressure variation is able to predict fluid responsiveness in patients in the operating room and intensive care unit (ICU).

However, this technique requires percutaneous arterial catheterization, which is associated with several rare but serious complications (thrombosis, infections, pseudoaneurysm,hematoma, and bleeding).

A method for assessing noninvasive arterial blood pressure using an electropneumatic control loop was introduced by Penaz in 1973. Briefly, the blood volume in a finger is measured and kept constant by applying corresponding external pressure. The continuously changing external pressure needed to keep the volume constant directly corresponds to the arterial pressure and, therefore can be used as continuous measurement of arterial blood pressure. Numerous studies evaluating the accuracy of this technology, e.g., Finapres™ (Ohmeda Monitoring Systems, Englewood, CO), and more recently of the Infinity CNAP™ SmartPod (Dräger Medical AG \& Co.KG, Lübeck, Germany).

The basic operating principle of the CNAP™ is similar to the Finapres™, but CNAP™ uses multiple control loops. It has recently been shown that CNAP provides real-time estimates of mean arterial blood pressure (MAP) comparable with those measured by an invasive intraarterial catheter system during general anaesthesia.

The accuracy of the measures and the respiratory variations in pulse pressure obtained with the CNAP system have not yet been studied in ICU.

Conditions

  • Systemic Inflammatory Response Syndrome
  • Circulatory Failure
  • Mechanical Ventilation

Interventions

OTHER

Pulse pressure variations

Stroke volume and, pulse pressure variations obtained by noninvasive (ΔPPCNAP) and invasive (ΔPPART) devices are recorded immediately before and after volume expansion (VE), performed as a 30-minute infusion of 500 mL of 4% gelatin.

Sponsors & Collaborators

  • University Hospital, Lille

    lead OTHER

Principal Investigators

  • Sébastien Preau, MD,PhD · University Hospital, Lille

Study Design

Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2012-04-30
Primary Completion
2013-06-30
Completion
2013-06-30

Countries

  • France

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03066388 on ClinicalTrials.gov