Respiratory Variations For Predicting Fluid Responsiveness 2
NCT03066375 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 55
Last updated 2017-02-28
Summary
Objectives: To investigate whether respiratory variations of inferior vena cava diameters (cIVC) predict fluid responsiveness in spontaneously breathing patients with septic acute circulatory failure and irregular heartbeats.
Design: Prospective, bicentric study, intensive care units.
Patients and measures: Spontaneously breathing patients with sepsis and clinical signs of acute circulatory failure are included. A positive response to fluid loading (FL) is defined as an increase of the stroke volume (SV) \>10%. The investigators measured the minimum inspiratory and maximum expiratory diameters of the IVC (idIVC and edIVC) during standardized (st) and unstandardized (ns) breathing. The investigators calculated cIVCst and cIVCns before a 500ml-colloid FL.
Conditions
- Sepsis
- Circulatory Failure
- Respiratory Physiological Phenomena
Interventions
- DEVICE
-
Echocardiography-Doppler
Ultrasonographic recordings are recorded immediately before and after volume expansion (VE), performed as a 30-minute infusion of 500 mL of 4% gelatin. Inferior Vena Cava diameters are measured during spontaneous and standardized respiratory cycles. Stroke volume is measured during spontaneous respiratory cycles.
Sponsors & Collaborators
-
University Hospital, Lille
lead OTHER
Principal Investigators
-
Sebastien Preau, MD, PhD · University Hospital, Lille
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-05-31
- Primary Completion
- 2015-05-31
- Completion
- 2015-06-30
Countries
- France
Study Locations
More Related Trials
-
Accuracy of Pulse Pressure Variations Measured by a Non Invasive Digital Device to Predict Fluid Responsiveness
NCT03066388 ·Status: TERMINATED ·Phase: NA
-
Respiratory Variations of the Diameter of Superior Vena Cava for Predicting Fluid Responsiveness After Cardiac Surgery
NCT03393897 ·Status: COMPLETED
-
Transthoracic Echocardiography of the Superior Vena Cava in Intensive Care Units (ICU) Intubated Patients
NCT03508401 ·Status: UNKNOWN ·Phase: NA
-
Discontinuous Echocardiographic Subcostal Cardiac Output Measurement
NCT07177391 ·Status: RECRUITING
-
LV Diastolic Function vs IVC Diameter Variation as Predictor of Fluid Responsiveness in Shock
NCT05066256 ·Status: UNKNOWN ·Phase: NA
-
Focused Assessed Echocardiography to Predict Fluid Responsiveness
NCT03044405 ·Status: COMPLETED ·Phase: NA
-
Inferior Vena Cava Compliance in Trans-thoracic Echocardiography: is the Trans-hepatic Window as Reliable as the Subcostal One
NCT04866095 ·Status: COMPLETED ·Phase: NA
-
Echocardiographic Evaluation of RV Injury in the ICU
NCT05525936 ·Status: NOT_YET_RECRUITING
-
Inter-observer Reproductibility of Visual Estimation of Left Ventricular Ejection Fraction in Critical Care
NCT04978389 ·Status: COMPLETED
-
Evaluation of the Association Between Right Atrial Reservoir Strain Variation and Fluid Responsiveness in Patients With Septic Shock
NCT06492044 ·Status: RECRUITING ·Phase: NA
-
Respiratory Variability in Aortic Blood Velocity Measured by Suprasternal View as an Indicator of Fluid Responsiveness
NCT02791984 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Right Ventricular Systolic Function Using Real-time Three-dimensional Echocardiography in Intensive Care Unit Patients
NCT04222764 ·Status: COMPLETED
-
SSVC-CI During CABG
NCT06645327 ·Status: RECRUITING
-
Cardiac Output Monitoring by Transpulmonary Thermodilution and Transthoracic Echocardiography in Critically Ill Patients
NCT04637126 ·Status: COMPLETED
-
Predicting Fluid Responsiveness in Mechanically Ventilated Critically Ill Children Using Transthoracic Echocardiography
NCT05054452 ·Status: COMPLETED ·Phase: NA
-
Dynamic Variation of Impedance Cardiography(DYVIC) as a Diagnostic Tool of Acute Heart Failure (AHF)
NCT03241069 ·Status: COMPLETED ·Phase: NA
-
Prognostic Value of Right Ventricular-pulmonary Arterial Coupling Assessed by Echocardiography in Septic Patients
NCT06887140 ·Status: NOT_YET_RECRUITING
-
Preload Dependency Evaluation With Stroke Volume Variation During Alveolar Recruitment Manoeuvres
NCT02678559 ·Status: COMPLETED ·Phase: NA
-
Impact of Gravity on Cardiac Hemodynamics
NCT06190756 ·Status: RECRUITING ·Phase: NA
-
The Doppler Feasibility Study
NCT06093373 ·Status: COMPLETED
-
Comparative Noninvasive Continuous Cardiac Output by the Clearsight® With Invasive Monitoring by PICCO® in Abdominal Major Surgery
NCT02941952 ·Status: COMPLETED ·Phase: NA
-
Echocardiography in Cardiac Resynchronization Therapy (Echo-CRT)
NCT02986633 ·Status: RECRUITING
-
Evaluation of Hemodynamic Changes of the Left Ventricle Following the Use of Extracorporeal Circulation
NCT03922178 ·Status: COMPLETED ·Phase: NA
-
Cardiac Output Assessment by Using Saline Contrast Injection
NCT04310904 ·Status: UNKNOWN
-
Value of Cardiac Output Monitoring by Supra-sternal Doppler/Echocardiography in Intensive Care Unit
NCT03952871 ·Status: COMPLETED