An Exploratory Clinical Study Non-invasive Monitoring of Cardiac Outputs
NCT05734664 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 8
Last updated 2023-02-21
Summary
Pulsify Medical aims at developing a sensor designed for the non-invasive, continuous and real-time monitoring of cardiac hemodynamics in patients at risk based on new transducer technology and artificial intelligence. It relies on real-time 3D greyscale ultrasound reconstruction of the LV myocardium. This medical device is still under development and the main objective of this clinical investigation is to gather data on the accuracy of the current version of the sensor developed by Pulsify Medical to further guide the development of the device. The data generated will not be used for conformity assessment and this single-center prospective study on 8 patients is therefore deemed appropriate for this purpose.
During the pretreatment visit, eligibility of the subjects for the investigation will be assessed. Once subjects are considered eligible and they have consented to participate in the investigation, the visit to perform the monitoring will be scheduled. An operator will then perform on each patient two scans with the Pulsify sensor. For accurate 3D reconstruction, the ECG and breathing cycle during the acquisition will also be recorded. Immediately after acquisition with the Pulsify sensor, an echocardiographist will record a complete 2D and 3D ultrasound data set using regular ultrasound equipment used for medical examinations in the hospital. The data generated will then be used to compare the accuracy of the Pulsify sensor for cardiac output measurements with state-of-the-art ultrasound. The data will also enable to acquire a dataset of ultrasound images taken with the Pulsify sensor technology in a manner that is very close to the image capture mechanism of Pulsify's final product.
Conditions
- Cardiac Output Measurements
- Healthy Subjects
Interventions
- DEVICE
-
Pulsify sensor
A positioning system will move the 1X1 cm Pulsify sensor step-by-step over a marked area of 10x10 cm on the subjects' chest to record a complete 3D data set of the heart. For accurate 3D reconstruction, the ECG and breathing cycle are also recorded during the acquisition using commercially available devices (Bitalino HeartBIT + Respiration Sensor). From the 3D dataset of the heart, the end-systolic and end-diastolic volumes will be extracted automatically to calculate the cardiac output.
- DEVICE
-
State-of-the-art ultrasound equipment
A complete 2D and 3D ultrasound data set using a GE Vivid E95 ultrasound machine, version 203 (General Electric Healthcare, Chicago, IL, United States) will be recorded. All data will be processed offline with a specialized software packet (EchoPAC, version 203, General Electric Healthcare, Chicago, IL, United States
Sponsors & Collaborators
-
KU Leuven
collaborator OTHER -
Universitaire Ziekenhuizen KU Leuven
collaborator OTHER -
Pulsify Medical
lead INDUSTRY
Principal Investigators
-
Alexander Van De Bruaene · UZ Leuven
-
Lieven Herbots · Pulsify Medical
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2022-10-19
- Primary Completion
- 2023-01-23
- Completion
- 2023-01-23
Countries
- Belgium
Study Locations
More Related Trials
-
Testing Automated Echocardiography
NCT04943965 ·Status: COMPLETED
-
Assessment of Left Ventricular Filling Pressure by Applying Artificial Intelligence Algorithms to Left Atrial Speckle-tracking Echocardiography
NCT05768698 ·Status: RECRUITING
-
Exercise Right Ventricular Coupling in HFpEF
NCT05731466 ·Status: RECRUITING ·Phase: NA
-
Prospective Evaluation of AI-ECG for SHD Detection
NCT07057466 ·Status: RECRUITING
-
Cardiac Flow Measurements in Pregnant Women by Non Invasive Techniques
NCT06114147 ·Status: RECRUITING ·Phase: NA
-
Safety and Efficacy Study of AI LVEF
NCT05140642 ·Status: COMPLETED ·Phase: NA
-
Validity of Cardiac Output Measurement Using Niccomo Device After Cardiac Surgery
NCT04643509 ·Status: UNKNOWN
-
Preload Dependency by Impedance Cardiography After Cardiac Surgery
NCT02132871 ·Status: COMPLETED
-
Validation of Automated Cardiac Output Measurement
NCT03372863 ·Status: COMPLETED
-
A Deep-Learning-Enabled Electrocardiogram for Detecting Pulmonary Hypertension
NCT07079592 ·Status: RECRUITING ·Phase: NA
-
Artificial Intelligence (AI) Analysis of Synchronized Phonocardiography (PCG) and Electrocardiogram(ECG)
NCT06009718 ·Status: RECRUITING
-
Evaluation of Left Ventricular Volumes by Real-Time 3-Dimensional Echocardiography
NCT00001740 ·Status: COMPLETED
-
Comparative Noninvasive Continuous Cardiac Output by the Clearsight With Invasive Monitoring by Pulsioflex in Abdominal Surgery
NCT02717468 ·Status: COMPLETED ·Phase: NA
-
Early Feasibility Study to Assess Safety and Device Performance of AcoustiCare™
NCT03751904 ·Status: WITHDRAWN ·Phase: NA
-
Accurate Measurement of Cardiac Output Using the Ultrasound Dilution Technique
NCT00851422 ·Status: COMPLETED
-
Study C3S : Comparison Among Healthy Subject
NCT03614624 ·Status: UNKNOWN ·Phase: NA
-
Validation of Kinocardiography, New Technology for Cardiac Linear and Torsional Contractility Measurement, to Assess Heart Failure Patient With Low Ejection Fraction
NCT03157115 ·Status: COMPLETED ·Phase: NA
-
Guided Placement of CRT-Leads
NCT00764075 ·Status: COMPLETED ·Phase: NA
-
Dynamic Variation of Impedance Cardiography(DYVIC) as a Diagnostic Tool of Acute Heart Failure (AHF)
NCT03241069 ·Status: COMPLETED ·Phase: NA
-
Electrophysiology of Fetal Arrhythmia
NCT03047161 ·Status: RECRUITING
-
Reliability of Minimally Trained Operator's Velocity-Time Integral Measurement Guided by Artificial Intelligence VTI
NCT06486467 ·Status: RECRUITING ·Phase: NA
-
Rest/Stress Quantification Of Left Ventricular Dyssynchrony By 3D Gated Blood Pool D-SPECT
NCT01390532 ·Status: UNKNOWN ·Phase: NA
-
Cardiac Output Monitoring in IVF Patients
NCT03713723 ·Status: UNKNOWN
-
Radiofrequency-based Speckle Tracking Echocardiography to Evaluate Diastolic Function
NCT01182805 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Assessment of the Force Frequency Relationship of the Myocardium After On-pump CABG Surgery
NCT02407574 ·Status: UNKNOWN ·Phase: NA