Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions
NCT05508711 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 40
Last updated 2022-08-19
Summary
The use of cardiac output monitoring to guide intraoperative fluid management and inotropic drugs as part of a hemodynamic therapy algorithm reduce the complication rate in major abdominal surgery. The FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device estimate cardiac output by using arterial pulse contour analysis. The accuracy of FloTrac/Vigileo have been proven in patients with normal cardiac index. Most of studies regarding FloTrac/Vigileo were performed in patients in horizontal supine position, which is not usually the reality in the operation theater during abdominal surgery. Therefore, the investigators realized this monocentric prospective clinical trial to study the accuracy and trending ability of the fourth generation FloTrac/Vigileo system cardiac output estimation in three different positions (horizontal supine, Trendelenburg and reverse Trendelenburg positions) in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output measurement used was the transesophageal echocardiography.
Conditions
- Cardiac Output
Interventions
- DEVICE
-
FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device
Concomitant cardiac output measurement with transesophageal echocardiography and with the FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device in 3 different positions (horizontal supine, Trendelenburg and reverse Trendelenburg position).
Sponsors & Collaborators
-
Université Libre de Bruxelles
lead OTHER
Principal Investigators
-
Lucélia FERNANDES RICCIARDI, M.D. · Université Libre de Bruxelles
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2021-10-01
- Primary Completion
- 2022-01-31
- Completion
- 2022-06-30
Countries
- Belgium
Study Locations
More Related Trials
-
Vigileo FloTrac vs Pulmonary Artery Catheter
NCT00641290 ·Status: UNKNOWN
-
Preload Dependency by Impedance Cardiography After Cardiac Surgery
NCT02132871 ·Status: COMPLETED
-
A Comparison of Stroke Volume Variation for Prediction of Fluid Responsiveness
NCT06215157 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Impedance Cardiography During Major Abdominal Surgery
NCT01611376 ·Status: COMPLETED ·Phase: PHASE4
-
Predicting Fluid Responsiveness in Mechanically Ventilated Critically Ill Children Using Transthoracic Echocardiography
NCT05054452 ·Status: COMPLETED ·Phase: NA
-
Early Goal Directed Therapy in Cardiac Surgery
NCT04292951 ·Status: COMPLETED ·Phase: NA
-
Real-time Continuous Cardiac Output Measurements
NCT04774978 ·Status: UNKNOWN ·Phase: NA
-
Respiratory Variability in Aortic Blood Velocity Measured by Suprasternal View as an Indicator of Fluid Responsiveness
NCT02791984 ·Status: COMPLETED ·Phase: NA
-
Transthoracic Echocardiography of the Superior Vena Cava in Intensive Care Units (ICU) Intubated Patients
NCT03508401 ·Status: UNKNOWN ·Phase: NA
-
Ambulant Monitoring to Detect Hemodynamic and Electrical Impact of Severe Tricuspid Valve Regurgitation
NCT07043465 ·Status: COMPLETED ·Phase: NA
-
Measure Cardiac Output Using Ultrasound Dilution in Mechanically Ventilated Children
NCT01662141 ·Status: COMPLETED
-
Validation of Capnography as a Predictor of Cardiac Output Change as Measured by FloTrac
NCT01880684 ·Status: COMPLETED
-
Cardiac Flow Measurements in Pregnant Women by Non Invasive Techniques
NCT06114147 ·Status: RECRUITING ·Phase: NA
-
Comparison Endotracheal Cardiac Output Monitor (ECOM) to a Standard Device in Measuring Heart Blood Volume
NCT00883857 ·Status: COMPLETED
-
Evaluation of Fluid Resuscitation in Shocked Patients by Electrical Cardiometry in Comparison to Transthoracic Echocardiography.
NCT06075407 ·Status: COMPLETED
-
Assessment of the Force Frequency Relationship of the Myocardium After On-pump CABG Surgery
NCT02407574 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Hemodynamic Changes of the Left Ventricle Following the Use of Extracorporeal Circulation
NCT03922178 ·Status: COMPLETED ·Phase: NA
-
Comparison Between NICOM-Cheetah and Flotrac-Vigileo for Cardiac Output Monitoring.
NCT03394768 ·Status: TERMINATED
-
Transhepatic Echography for Fluid Responsiveness After Cardiovascular Surgery
NCT04914455 ·Status: COMPLETED
-
Pulse CONtour and BIoimpedance for Measurements of Stroke Volume During Changes in CARdiac Preload
NCT04231656 ·Status: COMPLETED ·Phase: NA
-
Inferior Vena Cava Compliance in Trans-thoracic Echocardiography: is the Trans-hepatic Window as Reliable as the Subcostal One
NCT04866095 ·Status: COMPLETED ·Phase: NA
-
Focused Assessed Echocardiography to Predict Fluid Responsiveness
NCT03044405 ·Status: COMPLETED ·Phase: NA
-
Reliability of Minimally Trained Operator's Velocity-Time Integral Measurement Guided by Artificial Intelligence VTI
NCT06486467 ·Status: RECRUITING ·Phase: NA
-
Assessment of Stroke Volume in Shock Using Echocardiography Versus Bioreactive Impedance
NCT07020637 ·Status: RECRUITING
-
A Prospective Study to Bilaterally Compare a Non-Invasive Cardiac Output Monitor
NCT01678066 ·Status: UNKNOWN